SUPPLEMENTARY OPERATING MANUAL 2
2-2
02-04-03 CDP-01 Figure Sheet 1-856-A
External Control
CUSTOMER NETWORK TO FIFE NETWORK
Scheduled
Data Word1Data
Type2Variable Description
0 WORD Control
Matrix Used to control the CDP-01 in accordance with
the control matrix.
1 WORD Reserved
These values are reserved for state machine
communication.
2 WORD Reserved
3 WORD Reserved
4 WORD Reserved
5 WORD Reserved
6 WORD4 Line Speed Used to Input Line Speed.
1 All registers are 16-bit.
2 Data Types:
INT 16-bit signed value in the range of –32,768 to +32,767.
WORD 16-bit unsigned value in the range of 0 to 65,535.
3 Commands to the CDP-01.
4 Line Speed Input is a 10 bit WORD and has a range of 0 to 1,023.
Control Matrix
COMMAND VIA NETWORK HEX
AUTOMATIC W/OSCILLATION OFF 02
AUTOMATIC W/OSCILLATION ON 03
SEEK OVERIDE W/OSCILLATION OFF 0A
SEEK OVERIDE W/OSCILLATION ON 0B
MANUAL 06
SERVO-CENTER 04
JOG LEFT 16
JOG RIGHT 26
RGPC SHIFT LEFT 1*
RGPC SHIFT RIGHT 2*
RGPC RESET 3*
* RGPC works with the first four modes listed (Automatic and Seek Overide). The least significant
digit (far right) will need to remain constant. (i.e. RGPC shift right when in Auto with oscillation on
would be a hex value of ‘23’. RGPC shift left in Seek Overide with oscillation off would be a hex
value of ‘1A’.)
NOTE: If the Control Matrix is set to ‘00’, the CDP-01 will change to Manual mode.