Fife CDP-01 Manuale utente

05-19-06 CDP-01 Figure Sheet 1-900
© 2006 Fife Corporation. All rights reserved.
CDP-01
Additional Instruction Manual
For Armless Recoiler Application
With Staggerwind (Variable Ratio)
Using SE-21A Sensor And SBPC (MS: 100333)

05-19-06 CDP-01 Figure Sheet 1-900
© 2006 Fife Corporation. All rights reserved.

SUPPLEMENTARY OPERATING MANUAL i
05-19-06 CDP-01 Figure Sheet 1-900
COPYRIGHT
NOTE
These additional instructions explain the special features of the system delivered to the customer.
They are intended for being used in conjunction with the CDP-01 Reference Manual. The CDP-01
Reference Manual applies except as noted to the contrary in these instructions.
Copyright:
All rights reserved. Any reproduction of this Additional Instruction Manual, in any form, in whole or in
part, requires the prior written consent of FIFE.
The information given in this Additional Instruction Manual is subject to change without notice.
We have compiled this Additional Instruction Manual with the greatest possible care and attention:
however, the possibility of error can not be completely excluded. FIFE accepts no legal liability for
incorrect information given and the consequences arising therefrom.
Copyright ©2006 FIFE Corporation, P.O. Box 26508, Oklahoma City, OK 73126, U.S.A.
FIFE GmbH,Postfach 1240, D-65762 Kelkheim/Ts., Germany

05-19-06 CDP-01 Figure Sheet 1-900

SUPPLEMENTARY OPERATING MANUAL iii
TABLE OF CONTENTS
GENERAL INTRODUCTION 1
APPLICATION DESCRIPTION............................................................................................1-1
SOFTWARE PART NUMBERS...........................................................................................1-1
CONNECTING THE SYSTEM COMPONENTS ..................................................................1-1
OVERVIEW OF FUNCTION 2
OPERATOR CONTROL OPTIONS.....................................................................................2-1
SPECIAL FEATURES OF EXTERNAL CONTROL .............................................................2-1
INPUT MATRIX - EXTERNAL CONTROL...........................................................................2-2
NETWORK TRAFFIC ..........................................................................................................2-2
EXPLANATION OF THE OPERATING MODES........................................................2-3 to 2-5
START UP / POSITION TRANSDUCER CALIBRATION ..........................................2-6 to 2-7
START UP / SENSOR BANDWIDTH TO MANDREL RATIO CALIBRATION.....................2-8
START UP / GUIDING SENSOR CALIBRATION (GUIDE CHANNEL)...............................2-9
START UP / GUIDING SENSOR CALIBRATION (REFERENCE CHANNEL)...................2-10
START UP / SENSOR DRIVE POLARITY ........................................................................2-11
START UP / MANDREL DRIVE POLARITY......................................................................2-12
TROUBLESHOOTING 3
FAULT DIAGNOSIS - FAULT RECTIFICATION..................................................................3-1
05-19-06 CDP-01 Figure Sheet 1-900

05-19-06 CDP-01 Figure Sheet 1-900

SUPPLEMENTARY OPERATING MANUAL 1
1-1
GENERAL INTRODUCTION
Application Description
Application is a Armless Recoiler which uses linear analog position feedback for both the mandrel
and the sensor positioner. The mandrel to sensor positioner ratio is programmable. The SE-21A
sensor is used, which provides a reference channel for contamination compensation. An SBPC is
used for monitoring the system. The OSC-20 is used to provide oscillation of the web within the
proportional band of the sensor. External control via parallel input (X7) is required. When placed in
automatic mode, the sensor seeks the web edge. The sensor follows the web edge as long as
selected. Once Automatic is selected the sensor position and the mandrel position are recorded.
The sensor continues to follow the web edge and the mandrel then follows the sensor positioner. A
CDP-01-MHH with FifeNet firmware is required for this application.
Software Part Numbers
The software part numbers are located on the side of the CDP-01 housing. They include the Matrix
Setup no. (MS), State Machine no. (SM) and firmware version ( Dx ).
CDP version: CDP-01-H12 D1:565051-02x MS: 100333-02x Please quote these
D2:565052-02x SM: 100334-02x details with all inquiries.
D3:565052-02x FIFE USA
Connecting the System Components
The system components are to be connected according to the Cable Connection Diagram contained
in the documentation.
05-19-06 CDP-01 Figure Sheet 1-900

05-19-06 CDP-01 Figure Sheet 1-900

SUPPLEMENTARY OPERATING MANUAL 2
2-1
05-19-06 CDP-01 Figure Sheet 1-900
OVERVIEW OF FUNCTION
Operator Control Options
The CDP-01 signal amplifier can be operated by way of the CDP-01 control panel (internal operation)
for setup purposes only. For normal operational control, the parallel port (external operation) must be
used. Control is to be supplied from a remote control panel or programmable logic controller.
The symbols below are used for the various operator control options in the following:
Internal operation
External operation
Special Features of External Control
When the operation modes are being controlled via
external control, the Automatic, Servo-Center, Manual
keys of the CDP-01 control panel are disabled.
If the cable to the parallel port ( -X7 ) of the CDP-01 is
disconnected, the operation mode is changed to Manual
mode.

SUPPLEMENTARY OPERATING MANUAL 2
2-2
05-19-06 CDP-01 Figure Sheet 1-900
Input Matrix - External Control (X7)
Inputs CDP-01
Modes 15 14 13 12 11 10
Oscillator ON - - - - - H
Oscillator OFF - - - - - L
Automatic (seek, then guide) - H H L L -
Auto Permissive (seek only) - L H L L -
Manual (both drives) - - L L H -
Retract Sensor / Center Mandrel - L L H L -
Center Mandrel Only - L H H L -
Retract Sensor Only - H L H L -
Jog Mandrel Left L H L H H -
Jog Mandrel Right H L L H H -
Jog Sensor Out L H H L H -
Jog Sensor In H L H L H -
L= Low level
H= High level
-= any
Network Traffic
The table below shows the configuration mapping for data traveling from a Network to FifeNet.
Network to FifeNet Data
Scheduled Data Word Source1Data Type2Variable Description
0 WORD Device 1
Command3Network commands sent to the
CDP-01. Simulated key presses, etc.
The table below shows the configuration mapping for data traveling from FifeNet to a Network.
FifeNet to Network Data
Scheduled Data Word Source1Data Type2Variable Description
0 WORD Reserved Reserved
1 and 2 DWORD Reserved Reserved
3
4 DWORD Panel Data 0
Panel Data 1 CDP-01 LED panel data
5 WORD Device 1 Response3CDP-01 Fife Network responses
6 INT Edge Left Sensor Signal
7 INT Edge Right Sensor Signal
8 INT Line Center Sensor Signal
9 INT Line Edge Sensor Signal
10 WORD SM Command Feedback Reserved for State Machine control.
11 WORD SM Status Feedback Reserved for State Machine control.
12 WORD Common Status Register CDP-01 status
13 WORD Key pressed Current key pressed on CDP-01 panel.
14 WORD Drive 2 Operation Mode Drive 2 mode status
15 WORD Drive 2 Sensor Mode Drive 2 sensor status
16 WORD Drive 2 Fault Register Drive 2 fault status
17 WORD Drive 2 Alarm Register Drive 2 alarm status
18 WORD Drive 2 Operation Mode Drive 2 mode status
19 WORD Drive 2 Sensor Mode Drive 2 sensor status
20 WORD Drive 2 Fault Register Drive 2 fault status
21 WORD Drive 2 Alarm Register Drive 2 alarm status
1= All data words are 16 bits.
2Data Types:
*INT 16-bit signed value in the range of –32,768 to +32,767.
*WORD 16-bit unsigned value in the range of 0 to 65,535.
*DWORD 32-bit unsigned value in the range of 0 to 4,294,967,295.
3= Commands to the CDP-01.
Altri manuali per CDP-01
9
Indice
Manuali Hardware per computer popolari di altre marche

EMC2
EMC2 VNX Series Manuale del proprietario

Panasonic
Panasonic DV0PM20105 Manuale utente

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manuale utente

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manuale utente

Raidon
Raidon iT2300 Manuale utente

National Instruments
National Instruments PXI-8186 Manuale utente