Fine Offset Electronics WS80BN Manuale utente

Ultrasonic Wind Sensor
Model: WS80BN
FCC ID: WA5WS80BN
Contents
1. Introduction ......................................................................... 2
2. Get Started........................................................................... 2
3. Overview ............................................................................. 3
4. Setup Guide ......................................................................... 4
5. Mounting ............................................................................. 5
6. Calibration........................................................................... 8
7. Wi-Fi Configure with gateway ......................................... 8
6.1 Pair with Gateway or display console........................ 9
6.2 Wi-Fi Connection....................................................... 9
8. View Online Data on WS View ........................................... 9
9.Firmware upgrade............................................................... 10
10. Specification.................................................................... 14

1. Introduction
Thanks for your purchasing this WS80 6-in-1 Ultrasonic
Sensor. This device measures wind speed, wind direction,
temperature, humidity, UV Index and solar radiation. The
Ultrasonic Sensor is solar powered and sends data to the
console via a low-power radio. The data can be streamed by
GW1000 Wi-Fi Gateway (sold separately) or HP2550
console display (sold separately); and can be viewed on our
WS View mobile application after the Wi-Fi configuration
done.
To ensure the best product performance, please read this
manual and retain it for future reference.
The Ultrasonic Sensor is solar powered and sends data to
the console via a low-power radio.
2. Get Started
2.1 Parts List
One 6-in-1 Ultrasonic Sensor
One mounting arm with base
One Set of U-bolts for installation
One User Manual

3. Overview
Figure 1
1. Sonic wind sensor
5. Solar Power
2. Battery compartment
6. USB port
3. Temperature & humidity
7. Calibration button
4. Light sensor, LED
indicator
8. Reset button

4. Setup Guide
4.1 Install batteries
Insert 2XAA batteries in the battery compartment. The
LED indicator(on the top of the sensor) will turn on for
3 seconds and normally flash once every 4.75 seconds
(the sensor transmission update period).
Figure 2
Note: If no LED light up or is lighted permanently,
make sure the battery is inserted the correct way or a
proper reset is happened. Do not install the batteries
backwards. You can permanently damage the outdoor
sensor
We recommend lithium batteries for cold weather
climates, but alkaline batteries are sufficient for most
climates. We do not recommend rechargeable batteries.
They have lower voltages, do not operate well at wide

temperature ranges, and do not last as long, resulting in
poorer reception.
5. Mounting
Before you mount
Before installing your outdoor sensor in the permanent
location, we recommend operating the device for one week
in a temporary location with easy access. This will allow
you to check out all of the functions, insure proper
operation and familiarize you with the weather station and
calibration procedures.
1. Install the base on a pole(1.25inch~2inch) as Figure 3
Figure 3
2. Attaching Arm to Ultrasonic Sensor as Figure 4.

Figure 4
3. Insert the arm into the base as Figure 5. Be sure to
line up the small hole in the arm with the holes in the
base. Insert the machine screw through the holes in
the base and arm.
.
Figure 5

4. There is an arrow icon with ”N” words (Figure
6)representing the direction of North. The sensor body has
to be adjusted so that the “N” indication is facing to real
north direction in your location. A compass device is
recommended to help adjust direction. Permanent wind
direction error will be introduced when the outdoor sensor
is not installed in right direction
Figure 6

8
6. Calibration
The ultrasonic sensor has been calibration before
leaving the factory. We do not recommend that
customers do calibration by themselves.
Customers use this feature only when the wind speed
does not return to zero when there is no wind
After the product works normally, use a cloth or
sponge with good water absorption (prevent the echo
of the ultrasonic waves) to completely wrap the air
inlet.
With an open ended paperclip, press and hold the
CAL button for three seconds, the top LED light will
be on. After releasing the CAL button, place the
product on the table. After five seconds, the top LED
light will flash. At this time it is in the calibration
mode. Wait for the LED to flash, the calibration is
over, and the product automatically enters the normal
working mode.
7. Wi-Fi Configure with gateway
If you want to view the Ultrasonic Sensor data on
your mobile application, you need to pair this device

9
with our GW1000 Wi-Fi Gateway or HP2550 display
console (sold separately).
6.1 Pair with Gateway or display console
Please follow the tips to pair your sensor(s) with the
Wi-Fi Gateway or HP2550 display console:
(1). Power on the gateway first (with USB connection)
or HP2550 display console (with adaptor connection)
(2). Power on the Ultrasonic sensor.
(3). The RF status indicator of the gateway will light
on steady, and light off once when it receives the data
from the optional sensor(s) once.
(4). If work normally, you can forward to the Wi-Fi
connection operation.
6.2 Wi-Fi Connection
For this part, please refer to the manual of the
GW1000 Wi-Fi gateway or HP2550 Wi-Fi Weather
Station.
Any question, please contact the customer service.
8. View Online Data on WS View
When the Wi-Fi configuration is done, you can view
the live data of your rainfall sensor on the WS View
application.

10
9.Firmware upgrade
1. Download and install the Dfuse_Demo_V3.0.6
software. Open the installation path; choose to
Indice
Altri manuali Fine Offset Electronics Accessori


















