Firenzo Woodfires FORTE Istruzioni operative

Forte Flush & Athena Flush AG/RURAL - November 2018
Please read this booklet and keep for future reference for the safe installation of
your:
FORTE BAY & ATHENA BAY
AG & RURAL
INSTALLATION AND OPERATION GUIDE
FORTE
AG 103157
Aqualux AG 102107
RURAL Not Clean Air
ATHENA
AG 103157
Aqualux AG 102108
RURAL Not Clean Air
AG - AUTHORISATION NUMBERS ABOVE
AG = Air Guard (Clean Air – Environment Canterbury & Ministry for the Environment approved)
These Fires must be installed by someone competent to do so, Firenzo recommend the use
of a NZ Home Heating Association, solid fuel Fire installation technician (SFAIT), or other
suitably qualified person. The Fire and Flue System must be installed in accordance with
AS/NZS2918. All installations must be in accordance with these instructions. Consult with
the building authority having jurisdiction to determine the need for a permit prior to
commencing the installation. Failure to follow these instructions may also void your fire
insurance and warranty.
These Fires have been tested to Appendix E & B of the joint Australia/New Zealand
Standard 2918:2001
The AG Fire conforms with ECAN Requirements

Forte Flush & Athena Flush AG/RURAL - November 2018 2
PAGE: ITEM: TOPIC:
31Warnings
42Installation Responsibilities
43Floor Protection Requirements
5 Floor Protector Dimensions
6Fascia & Floor Protection Requirements
74Zero Clearance Box Assembly Instructions
8 - 15 Zero Clearance Box Framing
16 5 Pre Installations
17 6Assembly Instructions
18 Typical Insert Installation
19 7Wetback
20 8Insert Flue System
21 Fascade/Chase Termination
22 Minimum Height of Flue Outlet
23 9Fascia Assembly & Installation
24 10 Operating Instructions
25 Operating Instructions
26 11 Maintenance
27 12&13 Maintenance
28 - 30 14 Warranties
Your Warranties Registration Card is enclosed, please complete and return to us.
Under our policy of continuous product improvement, Firenzo reserves the right to
alter specification or product from that shown.
INDEX

Forte Flush & Athena Flush AG/RURAL - November 2018 3
1. WARNINGS
This Fire should be Maintained and Operated at all times in accordance with
these instructions.
The Forte Flush AG & Rural and the Athena Flush AG & Rural have been tested to N.Z. Standards
AS/NZS 2918:2001.
If this Fire is incorrectly installed a house fire may result. For your safety follow the installation
instructions carefully.
Do NOT connect the Fire to a chimney serving another Fire.
Although the exterior of the Fire may appear cool, contact with the Fire may cause burns; warn children
and others of the possibility of injury should they touch the Fire.
Do NOT dry clothing or unseasoned wood directly in contact with the Fire.
Keep all household combustible materials at least 600mm away from front of the Fire. This includes
clothing, furniture, wood, newspaper, plastic, matches, etc.
Do not use FLAMMABLE LIQUIDS or AEROSOLS in the vicinity of this Fire when it is operating
Use caution when reloading with fuel. Do NOT attempt to load fuel into the Fire when the fire inside the
stove is at or near its peak.
Do NOT burn large quantities of paper or combustible material that would create an extremely hot/quick
fire.
Do NOT burn highly coloured paper or brochures (junk mail).
USE ONLY DRY WOOD 25% or less moisture contact. AVOID BURNING WET OR GREEN WOOD.
The use of preservative treated wood as a fuel can be hazardous.
Timber treated with copper chromium and arsenic type preservatives will leave toxic residues in the ash,
firebox or within the flue, timber offcuts from building construction will often contain boric salts. The
combustion of this material over prolonged periods can produce adverse effects on refractory lining in
solid fuel Fires. Emission of poisonous gases can also be experienced with the burning of treated wood.
Driftwood with salt content will also cause rapid deterioration of the Fire and should not be used.

Forte Flush & Athena Flush AG/RURAL - November 2018 4
2. INSTALLATION RESPONSIBILITIES
Warning: The Fire and Flue system must be installed in accordance with AS/NZS 2918:2001 and the
appropriate requirements of the relevant NZ Building Code or Codes. If the flue system has been
AS/NZS 2918:2001 Appendix F tested by the flue system manufacturer then their specifications for the
installation of the flue system must be adhered to.
Any modification of the Fire that has not been approved in writing by the testing authority is considered
to be in breach of the approval granted for compliance with AS/NZS 4013.
Caution: Mixing of Fire or flue-system components from different sources or modifying the
dimensional specification of components may result in hazardous conditions. Where such action is
considered, the manufacturer should be consulted in the first instance.
Strict adherence to these instructions will meet these standards. Any variation from these installation
instructions or any doubt about them must be checked against the requirements of the standards.
Please leave this manual with the owner when installation is complete.
3. FLOOR PROTECTOR REQUIREMENTS
If the Fire is to be placed on or within 500mm of a heat sensitive floor, an insulated floor protector will
be required.
The insulated floor protector needs to extend under the Fire and in front of the door. See dimensions
for floor protector. Similarly a 200mm extension is required on each side of the door opening unless the
insulated floor protector forms an abutment with a wall or heat shield at a lesser distance.
The Fire and floor protector must be fixed to the floor for seismic restraint. Anchor points are provided
in the feet of the Fire.
INSULATED FLOOR PROTECTOR CONSTRUCTION
An Insulated Floor Protector shall be a minimum thickness of 40mm, consisting of 20mm of an
approved insulation material i.e. 2 sheets of 10mm Micorboard or Supalux, 10mm tile backing board
and 10mm tiles or similar on the top surface. All joints on the upper surface should be sealed to
prevent spilt ash from contacting any heat-sensitive material.

Forte Flush & Athena Flush AG/RURAL - November 2018 5
INSERT FLOOR PROTECTOR DIMENSIONS WHEN BEING INSTALLED
IN A MASONRY FIREPLACE
In a masonry fire place installation the standard front clearance from the fireplace breast (brickwork, etc)
can be reduced by increasing floor protector height.
INSERT FLOOR PROTECTOR DEPTH
HEIGHT FROM FIRE BREAST
Level 520mm
20mm 490mm
40mm 400mm
60mm 400mm(Min)
FLOOR PROTECTOR DIMENSIONS WHEN INSTALLING IN A ZERO
CLEARANCE BOX - ( Built-in Fire Canopy)
HEIGHT FROM FIRE BREAST
40mm 500mm

Forte Flush & Athena Flush AG/RURAL - November 2018 6
ZERO CLEARANCE BOX - Built-in Fire Canopy
Refer page 7 for
Built-in Fire Canopy
Dimensions

Forte Flush & Athena Flush AG/RURAL - November 2018 7
4. ZERO CLEAREANCE BOX
(Built-in Fire Canopy)
A Zero Clearance Box is required if the fire is not being installed
into a masonry fire place.
For Zero Clearance Box installations see the following pages 7 - 15
ZERO CLEARANCE BOX - Built-in Fire Canopy

Forte Flush & Athena Flush AG/RURAL - November 2018 8
ZERO CLEARANCE BOX - Built-in Fire Canopy

Forte Flush & Athena Flush AG/RURAL - November 2018 9
ZERO CLEARANCE BOX - Built-in Fire Canopy

Forte Flush & Athena Flush AG/RURAL - November 2018 10
ZERO CLEARANCE BOX - Built-in Fire Canopy