MONTAGE OF THERMOSTAT
Set the room thermostat on the wall with help of added screws
and model hools, which are drew on inside of packing cardboard.
It must be set 1.5m up from floor.
You must be careful where you montage the thermostat! Thermo-
stat should be placed on neutral place in the room, that means
that distance must be between thermostat and all heating bodies
(radiators, fireplace, ...), airing openings (window, door,...) and
chimneys at least 1m. Be careful on direct influence of the sun!
In case of incorrect montage, the room sensor will not perceive
correct room temperature, and will because of temperature influ-
ence come to differences, which will have for consequence to
high or in most cases to low actual temperature in the room.
Gas boilers, stove, kitchen-range or chimney also warm up the
wall. So you must be careful on these elements when you fixing
the thermostat on the wall. The thermostat must have at least 1m
distance from these elements!
Examples of incorrect montage
room thermostat room thermostat
gas
chimney
room thermostat
chimney
room thermostat
gas
boiler
Digital programmable timer makes possible to set heating regime for each day or group
of days. 20 program switches are available. The minimum setting of switching time is 1
minute. Digital programmable timer enables temporarily manual override of program
for switching between lower ( ,) and higher ( ,) temperature level. This manual
switching is active until next program switch.
Programmable room thermostat can be used for heating and cooling application with
suitable electrical connection.
Programmable room thermostat can control directly rotary actuator for mixing valve,
electric motor ball valve, circulation pump, burner, …
10
PROBLEM: SOLUTION
Days are flashing, pressing any key does
nothing except " " key turns output on
lower or higher temperature level.
Time of Day and Day of Week have not
been set. See “SETTING THE TIME”
Time of day was set while holding the
" " key down, but days are still flashing.
Current day of week was not set while
holding down the key. See “SETTING
THE TIME”
It is 10.00 and a program switch for
higher temperature level " " at 8.00
was entered, but the output is on lower
level state " ". Display shows the
" " and " " symbols.
After programming, the timer does not
“look back” to determine if it should be
on higher temperature level. Press the
" " key (temporary override) to turn the
output on higher level; " and "
appears in display. The timer will
assume automatic operation at the next
programmed event.
A program for 8AM Monday thru Friday
was entered, but it will not accept it and
" " is flasing,
The higher ( )/ lower ( ) level
switch was not entered as part of the
program.
" " or " " must be selected.
At turning both knobs for setting
temperature you not hear switches of
relays
- slide switch is in position " "
- batteries are exploitated
Display is beginning to fade or relay is not
switching
- batteries are exploitated. Expired time
of batteries is approximately 2 years
PROG. HEATING LEVEL
(HIGHER ) / (LOWER) H M DAY(S)
1 (Higher) 06 00 Monday – Friday
2 (Lower) 22 00 Monday – Friday
3 (Higher) 07 00 Saturday, Sunday
4 (Lower) 23 00 Saturday, Sunday
FACTORY SETTINGS
Program switch 1: heating on higher level at 06:00 Monday thru Friday
Program switch 2: heating on lower level at 22:00 Monday thru Friday
Program switch 3: heating on higher level at 07:00 Saturday and Sunday
Program switch 4: heating on lower level at 23:00 Saturday and Sunday
Four programs switches need to be entered.