FISNAR EP1320C Manuale utente

EP1320C OPERATION MANUAL
Rev. A - November, 2013
1 | P a g e
CARTRIDGE PUMP
MODEL EP1320C
◀OPERATION MANUAL▶

EP1320C OPERATION MANUAL
Rev. A - November, 2013
2 | P a g e
CONTENTS
1. Safety - - - - - - - - - - - - - - - - - - - - - - - - - 3
2. Introduction - - - - - - - - - - - - - - - - - - - - - - - - - 7
3. Specification - - - - - - - - - - - - - - - - - - - - - - - - 8
4. Control Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9
5. Installation / Set-up / Operation - - - - - - - - - - - - - - - - - - 11
6. Troubleshooting - - - - - - - - - - - - - - - - - - - - - - - - - 14
7. Exploded View / Parts List- - - - - - - - - - - - - - - - - - - - - - 15
8. Dimensions - - - - - - - - - - - - - - - - - - - - - - - - - - 20
9. Technical Data - - - - - - - - - - - - - - - - - - - - - - - - 21
Read the manual before installation and maintenance

EP1320C OPERATION MANUAL
Rev. A - November, 2013
3 | P a g e
SECTION 1
GENERAL SAFETY WARNINGS
1. Equipment Misuse Hazards
Any misuse of the dispensing equipment or accessories such as over-
pressurizing, modifying parts, using incompatible chemicals and fluids, or using
worn or damaged parts, can cause item to rupture and result in fluid splashing in
the eyes or on to the skin.
Never alter or modify any part of this equipment, doing so could cause it to
malfunction.
Check all dispensing equipment regularly and repair, or replace worn or
damaged parts immediately.
Always wear protective eyewear, gloves and clothing, as recommended by the
material and solvent manufacturers.
Never exceed the maximum air inlet pressure of 7 bar (100 psi).
Do not exceed the maximum working pressure of any component or accessory
used in the system.
Be sure that all materials and solvents used are chemically compatible with the
wetted parts. Always read the manufacturer's literature before using material or
solvent in this pump.

EP1320C OPERATION MANUAL
Rev. A - November, 2013
4 | P a g e
2. Hose Safety –High Pressure Hazards
High pressure fluid in the hoses can be very dangerous. If the hose develops a
leak, split or rupture due to any kind of wear, damage or misuse, the high
pressure spray emitted from it can cause material to splash in the eyes or on the
skin. Tighten all fluid connections securely before each use. High pressure fluid
can dislodge a loose coupling or allow high pressure spray to be emitted from the
coupling.
Never use a damaged hose. Before each use, check the entire hose for cuts,
leaks, abrasion or damage or movement of the hose couplings. If any of these
conditions exist, replace the hose immediately.
Do not try to re-couple high pressure hose or mend it with tape or any other
device. A repaired hose cannot safely contain the high pressure fluid.
Handle and route hoses carefully, do not pull on hoses to move equipment. Do
not use materials which are not chemically compatible with the hose.

EP1320C OPERATION MANUAL
Rev. A - November, 2013
5 | P a g e
3. Moving Parts Hazards
In order to lessen the danger of an accident, keep hands and fingers away from
the priming piston while the pump is installed and while air is introduced to the
pump.
Always follow the procedure of depressurizing the system before disassembling
and/or servicing the machine.
The air motor, the fluid area of pump and the motor will move whenever the
machine is activated. Keep hands and fingers away from the air motor during the
priming and installation of the pump.
Keep hands away from the edge of the ram or the pump bracket, hose and pad
plate.
All moving parts are covered by guards. The guards are removable for machine
setting and maintenance. Whenever these guards are removed for setting or
maintenance keep hands clear of any moving parts and pinch hazards.

EP1320C OPERATION MANUAL
Rev. A - November, 2013
6 | P a g e
4. Fire and Explosion Hazards
Static electricity may occur while fluid is in circulation through the pump and hose.
When not properly grounded, a spark may occur which can be dangerous. It can
occur whether the power cord is plugged or not. This spark may ignite any
solvent, dust particles and other combustible materials in or near the machine
and may cause fire, explosion, or serious injuries.
If you are shocked (even by a little) during the installation or normal operation,
stop dispensing immediately. Ground yourself properly to discharge any static
buildup. Do not use the equipment until the problem is completely checked and
safety is secured.

EP1320C OPERATION MANUAL
Rev. A - November, 2013
7 | P a g e
SECTION 2
INTRODUCTION
The EP1320C is a powerful medium ratio system for controlled fluid transfer from 1/10th
gallon (310ml) plastic cartridges –suitable for silicone-type fluids. The system integrates
a dual (A+B) tandem cartridge arrangement for continuous-flow management. A low-
pulse design allows automatic control of dispensing application.
The EP1320C tandem cartridge pump is designed to easily transfer material for
controlled dispensing via a high pressure valve. The suitable viscosity range is
10,000cps –600,000cps.
Rated at 15:1, the system provides a maximum of 995psi regulated material pressure.
The A&B cartridge management automatically switches from either A to B or B to A
when the cartridge is exhausted. Cartridges are contained in metal jacketed cylinders.

EP1320C OPERATION MANUAL
Rev. A - November, 2013
8 | P a g e
SECTION 3
SPECIFICATION
Power Requirements
220VAC ± 10%, 50-60Hz
Power Consumption
10W
Max Air Inlet
9.9kgf/cm2
Pump Ratio
15:1
Weight
18.5kg
Temperature Range
-5oC ~ 40oC
Dimension
272mm (W)
288mm (D)
649mm (H)

EP1320C OPERATION MANUAL
Rev. A - November, 2013
9 | P a g e
SECTION 4
Control Panel

EP1320C OPERATION MANUAL
Rev. A - November, 2013
10 | P a g e
No
Menu
Operation
Description
1
Lamp is on when power on
Lamp is off when power of
Power On/Off switch
2
Lamp On/Off
Cartridge is empty when light
is ON.
3
Indicates which side cartridge
is being used and/or replaced
Pressing Using selects which
cartridge is being used
Pressing Replace indicates
cartridge us being replaced
4
Lamp On/Off
Cartridge is empty when light
is ON.
5
Indicates which side cartridge
is being used and/or replaced
Pressing Using selects which
cartridge is being used
Pressing Replace indicates
cartridge us being replaced
6
Warning sounds
Sounds an alarm when the
material level is low
Replace with a new cartridge
7
Alarm signal out
I/O signal when material is
low.
The contact is broken when
material is low.
Indice
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente