TABLE OF CONTENTSTABLE OF CONTENTS
Introducon
Specicaons
Protecon Noce
Fing
Electrical
Installaon
Basic Requirements
Accessories
Gypsy Suitability
Above Deck Preparaon
Below Deck Preparaon
Above Deck Fing
Under Deck Fastening
Loading Rope/Chain
Electrical Wiring
Electric Cable Selecon
Wiring
Control Switch Installaon
Wiring Diagram
Operaon
Manual Control
Power Down/Up
Windlass Operang Procedures
Servicing
Servicing Schedule
Troubleshoong
Warranty
Product Guide
3
3
4
5
5
5
5
5
5
5
6
6
7
7
7
7
8
8
9
10
10
10
11
12
12
13
14
16

3
FIVE OCEANS ATLANTIC SERIES
1- Introducon1- Introducon
Thank you for choosing Five Oceans. Five Oceans products are world
renowned for their quality, technical innovaon and proven performance.
With a Five Oceans product you will be provided with many years of out-
standing service.
Product Support
Five Oceans products are supported by a network of distributors and Au-
thorized Service Representaves. If you encounter any dicules with this
product, please contact your naonal distributor, or your local Five Oceans
dealer. Details are available at: www.ve-oceans.com.
Important informaon about this manual
Throughout this manual, you will see safety and product damage warnings.
You must follow these warnings carefully to avoid possible injury or damage.
Atlanc 600
2 - Specicaons2 - Specicaons
1/2"(12mm) 6.96
D (mm) D (in) P (in) W (in)P (mm) W (mm)
0.274
0.329
21.46 .845 10.41 .410
8.36 26.16
mm in mm in mm in
140 5 1/2"248 197
1.030 12.70 .500
1/4" HT G4
9/16" (14mm) 5/16" HT G4
Atlanc 900
DD
PP
AA
WW
CC
9 3/4"7 3/4"
BB
AA
BB
CC
Atlanc 600
Electric SpecicaonsElectric Specicaons
12
12
Atlanc 900
MODEL
MOTOR
Voltage Wa
600
900
600
900
1200
1650
kg lb
MAXIMUM
PULL
26
35
m/min. /min.
DROP SPEED
85
115
180
250
400
550
kg lb
WORKING
LOAD LIMIT
20
35
Amp
NORMAL
CURRENT
DRAW

4HORIZONTAL WINDLASS MANUAL VOLUME ONE
3- Protecon Noce3- Protecon Noce
At all mes it is the responsibility of the boat user to ensure that the anchor and rode are
properly stowed for the prevailing sea condions. This is parcularly important with high-speed
powerboats, because an anchor accidentally deploying while under way can cause considerable
damage. An anchor windlass is mounted in the most exposed posion on a vessel and is thus
subject to severe atmospheric aack resulng in a possibility of corrosion in excess of that
experienced with most other items of deck equipment. As the windlass may only be used
infrequently, the risk of corrosion is further increased. It is essenal that the windlass is
regularly examined, operated and given any necessary maintenance.
Please ensure that you thoroughly understand the operaon and safety requirements of the
windlass before commencing the installaon. Only persons who are completely familiar with
the controls and those who have been fully made aware of the correct use of the windlass
should be allowed to use it. If there is any doubt of how to install or operate this unit please
seek advice from a suitably qualied engineer.
• Windlasses used incorrectly could cause harm to equipment or crew.
• Windlasses should be used with care and treated with respect.
• Boang, like many other acvies can be hazardous. Even the correct selecon, mainte-
nance and
• use of proper equipment cannot eliminate the potenal for danger, serious injury or
death.
• Five Oceans windlasses are designed and supplied for anchor control in marine applica-
ons and are not to be used in conjuncon with any other use.
• Keep limbs, ngers, clothing and hair clear of windlass and anchor rope/chain and anchor
during operaon. Severe bodily harm would result.
• Ensure there are no swimmers or divers nearby when dropping anchor.
• When the Windlass is not in use the anchor must be ed o onto a cleat or equivalent
strong point to prevent damage to the boat.
• Windlass must not be used as the sole means of securing the anchor to the bow ng
especially under storm condions. Anchors should be independently secured to prevent
accidental release.
• Classicaon Sociees require that a vessel lying at anchor must have its anchor rope/
chain secured to a chain stopper or other suitable independent strong point.
• A windlass should never be used as a mooring bollard, the anchor rode MUST be secured
to a mooring cleat, chain stopper or other designated strong point. Using the windlass to
secure the rode will damage the windlass.
• Do not use windlass for ANY purpose other than deployment and recovery of anchor.
• Do not wrap chain around a capstan barrel or drum where ed.
• A circuit breaker/isolator should always be used with this windlass to protect the motor
and cables from overheang and damage.
• Always switch o this windlass at the circuit breaker/isolator when not in use.
• It is the unavoidable responsibility of the owner or master or other responsible party to
assess the risk of any operaon on the vessel.
• Windlass must not be operated whilst under the inuence of alcohol or drugs.

5
FIVE OCEANS ATLANTIC SERIES
3.2 Fing3.2 Fing
• This equipment must be installed and operated in accordance with the instrucons con-
tained in this manual. Failure to do so could result in poor product performance, personal
injury and/or damage to your boat.
• Consult the boat manufacturer if you have any doubt about the strength or suitability of
the mounng locaon.
3.3 Electrical3.3 Electrical
• Make sure you have switched o the power before you start installing this product.
• This product requires installaon by a suitably qualied electrical engineer.
4.2 Accessories4.2 Accessories
Use only genuine Five Oceans parts and accessories to ensure top performance and eliminate
the risk of voiding your warranty. For replacement parts, please visit your dealer or
www.ve-oceans.com
4.3 Gypsy Suitability4.3 Gypsy Suitability
Gypsies ed to the Atlanc Horizontal windlasses are ideally suited to handling our factory
made Rope/Chain combinaon rodes, which consist of rope spliced to a chain tail. See 4.24.2
Specicaons for details.
Ropes used must be windlass grade, medium lay nylon. Ropes from dierent manufacturers
have wide variaons in stretch and consistency in diameter. Therefore, rope and chain from
othermanufacturers may require some experimentaon to determine the opmum size.
Should you have diculty in matching a gypsy to your chain please consult
info@ve-oceans.com.
4.4 Above deck preparaon4.4 Above deck preparaon
IMPORTANT - Plan locaon carefully and allow for the following:
4- Installaon4- Installaon
4.1 Basic requirements4.1 Basic requirements
Each installaon requires the following tools:
WINDLASS INSTALLATION
• An appropriate marine sealant
• Electric drill and 10mm (3/8”) drill bit
• 76mm (3”) Hole Saw
WIRING INSTALLATIONWIRING INSTALLATION
• Crimping Pliers / Wire Stripper
• Suitable electrical cable and crimp
terminals
25-60 mm
1" - 2 1/4"
21 3

6HORIZONTAL WINDLASS MANUAL VOLUME ONE
1. Use drilling template provided and choose an appropriate posion with reference to
the vessel’s bow roller and the chain locker below. Allow for the rotaon of the manual
operang wrench handle
2. If the deck is not at, a suitable mounng pad may be required to take up camber or
sheer.
NOTE: If in doubt about the suitable construcon of the pad consult a qualied marine
engineer.
The deck is an integral component of the windlass it has to secure the windlass and be
strong enough to cope with the high torque stresses involved in recovering the anchor.
Decks that are thin, or of foam or balsa laminate construcon, will require reinforcement
in order to spread the loads that will be applied to the deck while the windlass is in use.
3. Five Oceans recommends a minimum deck thickness of 25mm (1"), M8 Studs suit deck
and packing thickness of 25-60mm (1" - 2 1/4").
4.5 Below Deck Preparaon4.5 Below Deck Preparaon
IMPORTANT: The posioning of the windlass must be checked prior to cung for deck/hull and
bulkhead clearance. Lead from the roller should be fed horizontally back to the top of the gypsy
and along its centre line within +6˚. There must be sucient vercal fall (minimum
of 300 mm /12” at all mes) for the chain or rope when hauling in.
4.6 Above Deck Fing4.6 Above Deck Fing
Using the template and aer you have checked all the above and below deck requirements cut
the following holes: Using a 10mm (3/ three holes for the mounng studs and two for the 8”)
diameter drill bit, make the motor cables. With a 76mm (3”) diameter hole saw, make one hole
for the rode to pass through.
1. When all the holes have been made, remove the template. To help avoid water absorpon
by the deck, apply an appropriate marine sealant to the freshly cut hole edges.
2. Assemble and ghten studs into base unl they boom out in their holes.
3. Place the base mat in posion on the deck. Apply a suitable sealant to the base of the
windlass, any mounng pad or around the studs.
300 mm
(12”)
6°
1 2 3
WARNING! Failure to respect the
300 mm vertical fall may cause
malfunction.

7
FIVE OCEANS ATLANTIC SERIES
4.7 Under deck fastening4.7 Under deck fastening
1. Fit windlass to deck. Trim the studs back to 3/16” or 1/4” (5mm or 6mm) below the fully
ghtened nuts to prevent snagging anchor rope/chain if necessary.
• NOTE: If using silicone or other rubbery type sealant, it is advisable to allow curing of the
sealant before nal ghtening of the mounng nuts.
4.8 Loading rope/chain4.8 Loading rope/chain
For safety and performance Five Oceans recommends the use of matched Five Oceans anchor
rodes.
5- Electrical wiring5- Electrical wiring
5.1 Electric cable selecon5.1 Electric cable selecon
Five Oceans recommends the installer source and install cable that meets the requirements of
the standards and regulaons relevant to the installaon and codes of pracce.
The cable table gives recommended cable sizes based on total length of cable required, from
the baery, following the route of the cables.
CABLE SIZING FOR LENGTH OF CABLE RUN
1. Pull out control arm.
2. Feed anchor rope/chain into entry hole. Tie o to suitable strong point in the anchor locker.
3. Align rope/chain in gypsy. Release control arm and wrap rope/chain around gypsy.
4. Turn on the breaker and power load rest of anchor rope/chain.
Windlass performance is directly related to cable size and length. Voltage drop over the
complete wiring run must not exceed 10%.
DO NOT use a permanent
adhesive/sealant eg.5200
WARNING! Isolate (turn off) the
windlass using circuit breaker / isolator.
Atlanc 600 6 AWG (16 mm²) 2 AWG (25 mm²)
Atlanc 900 2 AWG (25 mm²) 1 AWG (35 mm²)
MODEL up to 24 (up to 8 m) 24 - 50 (8 - 16 m)
DO NOT confuse cable length
with the length of the vessel
3/16"5mm
6mm1/4"

8HORIZONTAL WINDLASS MANUAL VOLUME ONE
5.2 Wiring5.2 Wiring
Plan the installaon to suit the controls and give the operator a full view of the windlass. The
wiring system should be of the fully insulated type, which avoids possible electrolyc corrosion
problems.
We recommend the use of type III stranded, nned copper wire with copper crimp
terminals (NOTE: we recommend that the cable are shorter if possible.). Most modern installa-
ons are negave return (negave ground) but polarity should be checked. Overload protec-
on, in the form of the circuit breaker provided must be built into the windlass wiring circuit.
• Circuit breaker supplied:
Atlanc 600 Series (Circuit Breaker: 60 Amps - 80 Amps)
Atlanc 900 Series (Circuit Breaker: 80 Amps)
• The circuit breaker should be posioned close to the baery in a dry, readily accessible place.
• The breaker must be manually reset should an overload occur that causes it to trip to the o
posion.
Warning
If you are not sure you understand these guidelines, seek professional help. Ensure that the
installaon complies with USCG, ABYC, NMMA or other local regulaons.
5.3 Control switch installaon5.3 Control switch installaon
The unit is supplied with
Visit www.ve-oceans.com for more informaon
Contactor box (should be located within an dry area) and control box used in some installaon
refer to wiring diagram S 5.4

9
FIVE OCEANS ATLANTIC SERIES
5.4 Wiring Diagram5.4 Wiring Diagram
Positive Wire
Negative Wire
A2A2A1A1
M1M1 M2M2
CC
BatteBatteryry
12 VDC12 VDC
2
22
22
2
1
11
Main Switch
Rocker Switch
Electric Deck Switch
Foot Up Foot Down
FUSE
Motor Fuse
Solenoid
top view
side view
*For a safe and secure installation, place the Circuit Breaker as close to the battery as possible.
Circuit
Breaker*

10 HORIZONTAL WINDLASS MANUAL VOLUME ONE
6- Operaon6- Operaon
6.1 Manual Control
Use this method for quicker anchor deployment, in an emergency involving loss of power or to
save baery power. Observe marime anchor deployment safety rules.
6.2 Power Down/Up
1. Turn o all power to motor windlass and release any anchor locks.
2. When safe insert the Five Oceans wrench in to the capstan drive cap. Rotate clockwise to
grip the gypsy and anclockwise to free the gypsy controlling the rate of descent of the
anchor. Once deployed adjust desired scope if using a rope/chain, lock the clutch by turn-
ing the drive cap clockwise and engage the anchor locks. Remove the wrench handle.
To release anchor:
1. Check unit is not in manual mode.
2. Release any anchor locks.
3. Engage the circuit breaker/isolator.
4. Press down buon connuously unl you’ve reached the necessary length of chain/
rope.
5. Disengage the circuit breaker/isolator.
6. Lock anchor locks.
To retrive anchor:
1. Release any anchor locks
2. Engage the circuit breaker/isolator.
3. Press the UP buon connuously to retrieve the anchor.
4. Disengage the circuit breaker/isolator.
5. Lock anchor locks.
WARNING! Isolate (Turn off) the
windlass using circuit breaker / isolator.
WARNING! Trapping, crushing or
entanglement danger whiIst operating
windlass manually or under power
WARNING! Always remove
wrench handle aer use.
DONT FORGET
1 2 3
Questo manuale è adatto per i seguenti modelli
2
Indice
Manuali Attrezzatura nautica popolari di altre marche

Dowco
Dowco V322 CC - 2019 Manuale utente

Humphree
Humphree HCS-5 Manuale utente

Vetus
Vetus BOW4512D Scheda tecnica

Dock Doctors
Dock Doctors SLIDING BOARDING STEP Manuale utente

Mastervolt
Mastervolt Mass Combi 12/2000-100 Istruzioni operative originali

Zattini Group
Zattini Group bamar BOXTRON E14S Guida utente