Flowzone Vortex FZFAKZ Manuale utente

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 1 -
VORTEX
Model #: FZFAKZ
40V BATTERY POWERED MIST BLOWER
2.5-GALLON TANK CAPACITY
®
OPERATION GUIDE
™

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 2 -
!ATTENTION Please read the following information carefully. User must read and understand the entire manual
before operating the mist blower. Failure to follow instructions or improper use could lead to mist
blower failure and possible serious injuries.
This product contains chemicals, including lead, known to the state of California
to cause birth defects and other reproductive harm.
When using chemicals, always wear protective clothing, including respiratory
protection masks, gloves, eye protection, etc.
Do not dispose of Lithium-ion batteries with household waste; recycle where
facilities exist.
NEVER spray petroleum oil distillates, essential oils,
or acetone through your mist blower.
• DO NOT RETURN Mist blower TO
STORE. If you experience issues
or have questions, contact our
Support Team M-F 9am-5pm
EST at 1-803-339-2500 or email
support@wessol.com.
• Never spray ammable, caustic,
acidic, heat, pressure, or gas
producing chemicals.
• Always read and follow chemical
manufacturer’s instructions
before use with this mist blower as
some chemicals may be hazardous
when used with this mist blower.
• Never leave chemicals or solutions
sitting in your mist blower after
using.
• After using mist blower with
chemicals, it is important to spray
with fresh water for 3-5 minutes to
ensure residual chemicals in the
gun, wand, tank, pump, and hose
are cleaned out.
• Read and follow all instructions
and cautions on label of products
used in this mist blower.
• Do not store your mist blower in
extremely high temperatures.
Heat can lead to the build-up of
pressure within the mist blower,
resulting in a possible explosion.
• Do not try to make modications
to the mist blower. Always use
FlowZone®branded replacement
parts from the manufacturer.
• Do not use batteries that are wet
or have been damaged.
• Inspect mist blower hose, power
knob, wand, and gun for damage
or loose connections before each
use.
• Do not lift or carry the mist blower
by the hose, or wand. Carry by the
handle only.
• Only spray when the air is calm (no
wind or air movement) to prevent
chemical spray from drifting into
unintended areas.
• Keep mist blower and all chemicals
out of the reach of children.
• Remove chemicals and thoroughly
clean the mist blower after each
use. Failure to clean the mist
blower may cause contamination
of subsequent applications, will
cause premature mist blower
wear, and void the mist blower
warranty.
• Never mist in the direction of
humans, animals, or property
which might be injured or damaged
by high wind speeds.
• Never insert any foregn object
into the air intake of the machine
or into the nozzle of the mist
blower. It will damage the fan and
may cause serious injury to the
operator or bystanders as a result
of the object or broken parts being
thrown out at high speed.
• Wear heavy long pants, boots, and
gloves. Avoide loose garment or
jewelery that could get caught in
moving parts of the machine or its
motor.
• Keep hair, loose clothing, ngers,
and all body parts away from
openings and moving parts.
NOTES
• The mist blower may have residual
water in it when rst opened. This
is due to quality testing every mist
blower undergoes before leaving
our factory.
• Some parts may be located under
the tank lid when rst assembling
the mist blower.
• THIS Mist blower IS DESIGNED TO
OPERATE WITH ONLY FLOWZONE®
BRANDED 40V BATTERIES. ANY
OTHER BATTERIES COULD CAUSE
SERIOUS HARM OR INJURY TO
THE OPERATOR AND SERIOUS

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 3 -
DO NOT RETURN Mist blower TO STORE, if you experience problems or have
questions contact our Customer Support, M-F 9am-5pm EST at
+1 (803) 339-2500, or email: support@wessol.com, or nd more information
at fzspray.com/pages/troubleshoot.
OPERATING
• Do not allow familiarity with
products to make you careless.
Remember that a single moment
of carelessness is sucient to
cause serious injury.
• Always wear eye protection
with side shields when handling
or operating this mist blower.
Failure to do so could result in
serious injury from chemical
contact or ying dirt or debris.
• The Lithium-ion battery pack can
be used in temperatures down
to 32ºF. When operating in cold
temperatures, put the battery
pack in the battery compartment
and use the mist blower in a light
duty application. After about
a minute the battery pack will
warm up and begin operating
normally.
• Always use the correct power
setting for your application.
Using the correct PSI and ow
rate will result in a safer and
more thorough treatment. For
calibration resources please
contact FlowZone® technical
support. (Note: Always refer to
local, state, and federal laws
and regulations regarding your
application.)
• Do not use the mist blower if the
power switch is not functioning
correctly. Any power tool that
cannot be controlled with the
switch is dangerous and must be
repaired.
• Remove battery before making
any adjustments, changing
accessories, or storing the mist
blower. Disconnect the mist
blower from the power source by
removing the battery pack. These
preventative safety measures
reduce the risk of starting the
mist blower accidentally.
STORING
• Store mist blower out of reach of
children and do not allow persons
unfamiliar with the power tool
or these instructions to operate
the mist blower. Power tools
are dangerous in the hands of
untrained users.
• Maintain mist blowers and
accessories. Check for
misalignment or binding of
moving parts, breakage of parts
and any other condition that
may affect the mist blowers
operation.
SAFETY
• Use the mist blower and
accessories in accordance
with these instructions, taking
into consideration the working
conditions and the work to be
performed. Use of this mist
blower for applications that it was
not intended for could result in a
hazardous situation.
• Keep handles and lift points
dry, clean and free from oil and
grease. Slippery handles and
lift points do not allow for safe
handling and control of the mist
blower.
• Risk of re or explosion: Never
use this mist blower with liquids
such as gasoline, ethanol,
methanol, or any other ammable
or gas producing chemicals.
Do not use mist blower around
sparks, ame, or smoke. Failure
to adhere to these instructions
may cause ignition, resulting in
potential injury and damage to
property.
• To reduce the risk of re, personal
injury, and product damage from
a short circuit, never immerse
the mist blower, battery, or
charger in uids. Do not place
or store mist blower where it
could fall or be pulled into a tub
or sink. Corrosive or conductive
uids, such as seawater, certain
industrial chemicals, and bleach
or bleach containing products,
etc., can cause a short circuit.
• Electric shock hazard: Never
spray toward electrical outlets.
• Spray area must be well ventilated
to avoid hazardous fume build-
up. Always refer to the product
label of the chemical being used
for safety instructions and proper
use practices.
• Avoid spraying on windy days.
Spraying in windy conditions
could cause chemicals to be
blown onto persons, plants, or
objects that are not intended to
be sprayed.

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 4 -
REGISTER YOUR MISTER!
To take advantage of the 1-year Limited Warranty
from WESSOL, LLC. Register your mist blower at the
website below:
fzspray.com/register
Please read and follow this manual carefully to ensure
that you get the most out of your new mist blower. If
you need assistance with the assembly or operation
of your mist blower, please don’t hesitate to contact
WESSOL via the support methods below:
fzspray.com
spraysquad@fzspray.com
SAFETY CONT.
• Do not store chemicals in the
tank. Chemicals can degrade
seals and hoses. Drain and
clean mist blower after each
use. Failure to do so may void
the mist blower warranty.
• Remove gloves before handling
battery pack. Chemicals may
be damaging to plastics.
• Thoroughly inspect the
interior, exterior, and all
components of the mist blower
before each use. Check for
cracked and deteriorated
hoses, leaks, clogged nozzles
and missing or damaged parts.
If damaged, ensure the mist
blower is repaired before use.
Many accidents are caused by
poor maintenance.
• Always remove the battery
pack from the mist blower
before performing any
maintenance, storing or
draining of the mist blower.
• Do not eat or smoke while
handling or operating the mist
blower. Refer to the product
label of the chemical being
used for user safety practices.
• Do not use the battery
compartment for storage.
• Always use common sense and
be cautious when using the
mist blower. It is not possible
to anticipate every situation
that could result in a dangerous
outcome. Do not use this mist
blower if you do not understand
these operating instructions or
if you feel the work is beyond
your capability.
• Maintain labels and
nameplates. These carry
important information. If
unreadable or missing, contact
FlowZone® Support.
Manuals are subject to updates.
Scan the QR code to view the
most updated manual online!
or visit: www.fzspray.com/operation-guides

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 5 -
!THE BATTERY
These batteries have been designed
to provide maximum trouble-free life.
However, like all batteries, they will
eventually wear out. Do not disassemble
battery pack and attempt to replace the
batteries. Handling of these batteries
especially when wearing rings or jewelry
could result in serious burns.
• Recharge only with the charger
specied by FlowZone®. A charger
that is suitable for one type of
battery pack may create a risk of re
when used with another batter pack.
• Only use mist blowers specically
designated with their designated
battery packs. Use of any other
battery packs may create a risk of
injury and re.
• When battery pack is not in use, keep
it away from other metal objects,
like paper clips, coins, keys, nails,
screws or other small metal objects,
that can make a connection from
one terminal to another. Shorting
the battery terminals together may
cause burns or res.
• Under abusive conditions, liquid can
be ejected from the battery; avoid
contact. If contact accidentally
occurs, ush with water. If liquid
contacts eyes, seek medical help.
• Liquid ejected from the battery may
cause irritation or burns.
• Do not use a battery pack or mist
blower that is damaged or modied.
Damaged or modied batteries
may exhibit unpredictable behavior
resulting in re, explosion or risk of
injury.
• Do not expose a battery pack or
mist blower to re or excessive
temperature. Exposure to re or
temperature above 265˚F (130˚C)
may cause explosion.
• Follow all charging instructions
and do not charge the battery
pack outside the temperature
range specied in the instructions.
Charging improperly or at a
temperature outside the specied
range may damage the battery and
increase the risk of re.
STORING BATTERY PACK
LONGER THAN 30 DAYS
• Store the battery pack where the
temperature is below 80˚F and
away from moisture.
• For long-term storage, regular
charging of the battery is required
to maximize battery life. Check the
battery level using the indicator
lights every 4 weeks. Recharge the
battery if it falls below 3 bars.
• Do not allow the battery to fully
discharge.
BATTERY RECYCLING
PREPARATION
• To preserve natural resources,
please recycle or dispose of the
batteries properly.
• This product contains Lithium-ion
batteries. Local, state or federal
laws may prohibit disposal of
lithium-ion batteries in ordinary
trash. Consult your local waste
authority for information regarding
available recycling and/or
disposal options.
LITHIUM-ION BATTERY
PACKS
• Lithium-ion batteries deliver
fade free power for their entire
run time. Lithium-ion batteries
will not gradually lose power due
to decreasing battery charge.
Instead, power form the battery
pack will drop from full to zero
once the full charge has been
drained from the battery. Once this
happens, recharging of the battery
is required.
BATTERY PACK
PROTECTION FEATURES
• Lithium-ion battery packs are
designed with features that
protect the lithium-ion cells and
maximize battery life. If the mist
blower stops during use, release
the trigger to reset and resume
operation. If the mist blower still
doesn’t work, the battery needs to
be recharged.
If after 2 hours during the charging
process, none of the LEDs are lit,
remove the battery pack from the
charger to avoid damaging the
product. DO NOT insert another
battery. Contact Customer Support
for instructions on replacing
the battery.

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 6 -
CONTENTS:
ABOUT
07 Specifications
08 What’s Inside
09 Parts Diagram
SET UP
10 Mist blower Assembly
12 How to Spray
14 Aftercare
TROUBLESHOOT
14 Common Solutions
16 Parts & Accessories
18 Warranty

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 7 -
WHAT IS YOUR MISTER
CAPABLE OF?
This FlowZone® mister is a highly ecient mist blower that is
suitable for delivering many kinds of chemicals and solutions.
Powered by a 40V Lithium-ion battery, this mist blower results in more eciency
than a gas powered mist blower.
FlowZone® VORTEX™ Specications
Model Number FZFAKZ Pump Type Heavy-duty
diaphragm
Battery Type Lithium-ion Spray Time Up to 1 hour
Battery Voltage 40V Micron Size
Battery Capacity 8Ah Blow Distance
Battery Charging
Time 2 hours Tank Capacity 2.5 gallon
Battery Cycle Life 1,000 cycles Flow Rate
Battery Charger 40V/5A Pump Life 1,000 hours
Air Flow Speed

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 8 -
# Name # Name # Name
1 Tank Lid 7 Mid & Front Tube Asssembly 13 40V Battery Charging Dock
2 Tank Strainer 8 Bellows Tube
3 2.5-Gallon Tank 9 U-Clip
4 ComfortStraps™ 10 Clamps
5 Lower Housing 11 Nut & Bolt
6 Outlet Tube 12 40V Li-Ion Battery
WHAT’S
INSIDE
For part numbers
and replacement
parts/accessories
please see pages
9 & 19.
1
2
4
5
6
7
8
9
10
11
12
13
3

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 9 -
ASSEMBLY
1. Bring the ComfortStraps™ (4) to
the bottom of the Lower Housing
(5). Attach the strap clips to the
loops on the housing.
2. Take the top of the ComfortStraps™ and slide it through the loops at the top of the Lower
Housing. Feed the strap under and over the strap buckle. Gently tug on the strap to tighten in
place and ensure it is secure.
3. Slide the Outlet Tube (6) into the opening on the side of the Lower
Housing. Note: Make sure to line up the indented groove on the
Outlet Tube with the slot of the connection.
4. Remove the rubber bumpers and nuts from the U-Clip (9). Slide
the U-Clip into the slot of the Outlet Tube.

TYPHOON 3 OPERATION GUIDE
FZVAAK-3
© WESSOL, LLC 2022
- 10 -
5. Slide the rubber bumper onto the U-Clip where the threads
protrude from the slot below.
6. Secure the rubber bumper by
screwing the nut in place. Repeat
for the other side of the U-Clip.
7. Place a Clamp (10) over one end of the Bellows Tube (8). Place it over the opening of the Outlet Tube.
Tighten the Clamp using a athead screwdriver.
ASSEMBLY
Continued.