FLUENCE RAY Series Manuale utente

RAY 22
RAY 44
RAY 66
IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS . . . . .2
BEST PRACTICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
GENERAL CARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SYSTEM HARDWARE & ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . 6
ASSEMBLY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
CAUTIONS & WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
PRODUCT GUARANTEE & WARRANTY. . . . . . . . . . . . . . . . . . . . . . 12
USER MANUAL
RAY Series

2
IMPORTANT SAFETY PRECAUTIONS
AND EXPLANATION OF SYMBOLS
• Please read this manual thoroughly before attempting to install or
operate any Fluence RAY Series system.
• After successful installation and configuration of the system, be sure to
retain this manual in a safe place for future reference. Safety is a key
component to a long lasting and trouble free installation.
• It is important you read, fully understand, and observe the subsequent
safety precautions. If you are not comfortable with the installation of
high performance lighting systems, you should seek the services of a
qualified installation professional or call us for help.
• NOTICE: RAY is a high-performance lighting system. Do not touch
while in operation.
• Connect the system only to the power sources of the appropriate
voltage using the AC plug type received. Protect power cables from
being pinched, walked on, or otherwise damaged. Be especially
careful where the power cable enters the power outlet and the unit.
Only connect the system to an electrical outlet or extension cord of
appropriate type and rating. Connect the system only to the power
sources of the correct voltage using the plug received.

3
• DO NOT defeat the safety purpose of a grounding or polarized plug by
removing ground pins or using unsafe adapters. A polarized plug has two
blades –one wider than the other. A grounding plug has a third ground prong
in addition to the two main conductors. The wide blade or third grounding
prong is provided for your safety. If the provided plug does not fit your outlet,
consult an electrician to replace your obsolete outlet. If you replace the
power cord, only use one of similar type and equal or greater current rating.
• The system should only be cleaned as directed in the manual. You should
seek service for your system by qualified service personnel if any of the
following occur:
1. The power-supply cord or the plug has been damaged.
2. The unit has been exposed to rain.
3. The unit exhibits a marked change in performance.
4. The unit has been dropped, or its enclosure or chassis is damaged.
BEST PRACTICES
Fluence encourages everyone to experiment and pursue their own
techniques. Every crop is different and everyone has different goals.
However, our internal research has given us insight into several strategies
we would like to share.
• Regularly check your plants’ growth and health. Fluence lighting systems
deliver high levels of PAR, typically more than experienced in nature.
Adjustments to H2O, CO2, RH, nutrients, and temperature are typically required.
• Mount the fixture at least 6” from the top of your canopy to ensure
optimal uniformity and consistent PPFD. The RAY Series was designed to
provide uniform light dispersion and requires precise deployment. A 1”
variation in either direction will have a significant change in uniformity
and PPFD (which may or may not be desired).
• Many plants prefer higher temperatures when exposed to high PPFD.
Experiment with higher temperatures to achieve higher yields. Canopy
temperature and room ambient temperature often vary. For accurate
results, test at the canopy level to gauge leaf surface temperature.
For cultivation recommendations visit
fluence.science/science-articles/

4
GENERAL CARE
• RAY Series systems are passively cooled with zero moving components.
They are designed for harsh environments and years of maintenance-free
performance. Some basic care will keep your system operating at peak
performance cycle-after-cycle.
• Natural convection removes heat away from the heatsink. In order for
the system to properly cool itself, at least one inch of space is required
between the fixture and the surface it is mounted to. Failure to provide
adequate space may shorten the fixture’s lifespan.
• To achieve the optimal lifespan and performance of your fixtures, routinely
check for and remove excess dust, debris, and mineral build up from
heatsink and LED array. Cleaning should always be done with the fixture
unplugged from its power source using low-pressure compressed air or
water to rinse away dirt from light bars.
• Never use a cloth to clean the diode array. Doing so can scratch or
compromise the integrity of the silicon seal, or dislodge diodes entirely.
• To limit degradation, avoid touching the diodes with your hands, even in a
powered off state.
For detailed instructions for maintenance and cleaning,
please visit fluence.science/support-center/

5
RAY is a high-performance lighting system.
Do not touch while in operation.
PLEASE RECYCLE ALL
PACKAGING MATERIAL

6
Mounting Hardware
Mounting Hardware
Mounting Hardware
SYSTEM HARDWARE & ACCESSORIES
SYSTEM HARDWARE
ARAY fixture pre-configured with:
A1 8’ Cord with Male DC Connector
BPower Supply pre-configured with:
B1 14” Cord with Male AC Connector
B2 13.5” Cord with Female DC Connector
B3 13.5” Cord with 3-Pin Waterproof Dimming
Connector and Dust Cap (dimmer sold separately)
B4 Pigtail Dimming Adapter (purple/gray leads)
ACCESSORIES
C Mounting Hardware
(depending on your selection at the time of purchase)
C1 (2x) Standard top-light mounting brackets
C2 (1x) 6’ AC cable
(15’ cable option if upgraded at time of purchase)
A
C
C1 C2
A1
B
B1 B3
B4
B2

7
Take caution when
handling RAY fixtures.
Ensure the LED array does
not come in contact with
sharp objects or force that
may damage the diodes.
ASSEMBLY INSTRUCTIONS
Unbox RAY fixture and place on flush, stable surface.
To mount fixture, refer to the instructions included in the
hanging kit package with the associated accessories.
Hang the fixture in the desired location and adjust the
mounting height to at least 6” above the plant canopy.
Connect fixture to power supply using the 8’ DC cable
attached to the RAY fixture.
Mount the power supply to a wall or suitable support
structure using 4mm/#8 fasteners (not included) through
the mounting flange on the sides of the power supply.
Attach 6’ (or 15’) AC cable to power supply AC connector.
Finally, insert AC plug into wall outlet.
If connecting RAY to a dimming system or controller, remove
dust cap and connect to the 3-pin waterproof dimming
connector or the included pigtail dimming adapter.
Note, leave dust cap attached to connector
when not dimming fixture.
1
2
3
4
5
6

8
TECHNICAL SPECIFICATIONS
STOCK KEEPING UNIT (SKU) CONFIGURATOR & OPTIONS
(Example SKU: R-22-I-1-06-N5-R)
PHOTON FLUX AND EFFICACY
Family Model Spectrum Input Voltage AC Cord Length AC Plug Mounting Hardware
RR RAY 222” IPhysioSpec Indoor™1100-277V 06 6.0’ (1.83m) N5 NEMA 5–15P RStandard
444” GPhysioSpec Greenhouse™15 15.0’ (4.57m) N6 NEMA 6–15P
666” AAnthoSpec™L7 NEMA L7–15P
FPfrSpec™PT Pigtails
RPrSpec™
UUvSpec™
RAY 22 RAY 44 RAY 66
Spectrum Photon Flux
(µmol/s)
AC Power
(W)
Efficacy
(µmol/J)
Photon Flux
(µmol/s)
AC Power
(W)
Efficacy
(µmol/J)
Photon Flux
(µmol/s)
AC Power
(W)
Efficacy
(µmol/J)
Indoor 93 40 2.33 185 79 2.34 278 115 2.42
Greenhouse 93 40 2.33 185 79 2.34 278 115 2.42
Antho 79 43 1.84 158 87 1.82 237 126 1.88
Pfr 81 32 2.53 162 65 2.49 243 94 2.59
Pr 91 37 2.46 182 74 2.46 273 108 2.53
UV 33 39 0.85 66 78 0.85 99 114 0.87
Photon Flux (360-780nm) | AC Power @ 277 V | Efficacy (360-780nm) @ 277 V AC

9
DIMENSIONS
RAY 22 1.3 lb (0 .6 kg) 22” x 1.4” x 2.2” ((55.9 cm x 3 .6 cm x 5 .6 cm)
RAY 44 2.2 lb (1.0 kg) 44” x 1.4” x 2.2” (111.8 cm x 3 .6 cm x 5 .6 cm)
RAY 66 3.1 lb (1.4 kg) 66” x 1.4” x 2.2” (167.6 cm x 3 .6 cm x 5 .6 cm)
Mounting Hardware
2.2” (5.58 cm)
10.25” (26 cm)
9.25” (23.5 cm) 13.5” (34.3 cm)14” (35.6 cm)
1.4”
(3.6 cm)
8’ (2.43m)
14” (35.6 cm)
1.56”
(4.0 cm)
22” (55.6 cm) | 44” (111.8 cm) | 66” (167.6 cm)

10
MAXIMUM AC INPUT AMPERAGE
Spectrum AC Voltage 120 V 208 V 240 V 277 V
RAY 22
Indoor
Max AC
Input Current
0.34 A 0.20 A 0.17 A 0.15 A
Greenhouse 0.34 A 0.20 A 0.17 A 0.15 A
Antho 0.38 A 0.22 A 0.19 A 0.17 A
Pfr 0.28 A 0.16 A 0.14 A 0.13 A
Pr 0.32 A 0.19 A 0.16 A 0.14 A
UV 0.34 A 0.20 A 0.17 A 0.15 A
RAY 44
Indoor
Max AC
Input Current
0.69 A 0.40 A 0.36 A 0.32 A
Greenhouse 0.69 A 0.40 A 0.36 A 0.32 A
Antho 0.76 A 0.45 A 0.39 A 0.36 A
Pfr 0.57 A 0.33 A 0.30 A 0.27 A
Pr 0.64 A 0.38 A 0.33 A 0.30 A
UV 0.68 A 0.40 A 0.35 A 0.32 A
RAY 66
Indoor
Max AC
Input Current
1.02 A 0.59 A 0.50 A 0.44 A
Greenhouse 1.02 A 0.59 A 0.50 A 0.45 A
Antho 1.12 A 0.65 A 0.56 A 0.49 A
Pfr 0.84 A 0.49 A 0.42 A 0.37 A
Pr 0.96 A 0.55 A 0.47 A 0.42 A
UV 1.01 A 0.58 A 0.50 A 0.44A
Altri manuali per RAY Series
1
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali FLUENCE Attrezzatura di illuminazione

FLUENCE
FLUENCE RAY Series Manuale utente

FLUENCE
FLUENCE VYPR DUO 3x2 Guida alla risoluzione dei problemi

FLUENCE
FLUENCE VYNE Guida alla risoluzione dei problemi

FLUENCE
FLUENCE SPYDR 2x Manuale utente

FLUENCE
FLUENCE RAPTR Guida alla risoluzione dei problemi

FLUENCE
FLUENCE VYPR 2 Series Manuale utente

FLUENCE
FLUENCE SPYDR 2 Series Manuale utente