Franklin Electric SubDrive Duplex Alternator Manuale utente

Installation Manual
SubDrive Duplex
Alternator

Contents
Descriptions and Features.......................................3
Included Items ................................................4
How It Works................................................5-6
Before Getting Started ..........................................6
Controller Location Selection ....................................7
SubDrive Duplex Alternator Quick Reference Guide .................8
Installation Procedure ..........................................9
Wiring Connections ........................................10-13
Start-Up and Operation .....................................13-14
Mounting Dimensions .........................................15
Accessories..................................................15
Diagnostic Fault Codes ........................................16
Specifications ................................................17
Appendix
1. Duplex Inline Constant Pressure Quick Reference Guide ..........18
Tables
1. SubDrive, MonoDrive, and Inline Models .........................3
Figures
1. Mounting Screws ............................................9
2. Drive Sensor Cable Connections ..............................10
3. Pressure Sensor Connections.................................11
4. Alarm Connections ..........................................13
SubDrive Duplex Alternator

SubDrive Duplex Alternator
3
Model Name P a r t N u m b e r Use with SubDrive Series
SubDrive Duplex
Alternator
5850012000 5870203380 SubDrive75 NEMA 1
5870203384 SubDrive75 NEMA 4
5870204100 SubDrive100 NEMA 1
5870204104 SubDrive100 NEMA 4
5870204150 SubDrive150 NEMA 1
5870204154 SubDrive150 NEMA 4
5870206300 SubDrive300 NEMA 4
5870203223 SubDrive2W
5870203110 MonoDrive NEMA 1
5870203114 MonoDrive NEMA 4
5870204110 MonoDriveXT NEMA 1
5870204114 MonoDriveXT NEMA 4
90401101 Inline 1100
90411101 Inline CP
Table 1: SubDrive and MonoDrive Models
Note: SubDrive Duplex Alternator will work with any combination of the listed
Franklin Electric SubDrives/MonoDrives.
Descriptions and Features
The Franklin Electric SubDrive Duplex Alternator allows for two Franklin Electric
SubDrive units to operate on the same water system and share the work load
equally. The Alternator will alternate between the two SubDrive units when the
dened amount of run time has been reached. The Alternator is specically
designed for use with Franklin Electric SubDrive products (see Table 1 above).
Key features of the Alternator include the following:
• Works with entire SubDrive
product family
• Selectable alternate timing
• Pump status indicator lights
• Fault detection
• Fail safe operation
• Manual override push-button
• Alarm circuit contacts
• NEMA 4 enclosure
• Low voltage wiring connections

4
SubDrive Duplex Alternator
4
Included Items
A. Controller Unit
B. Sensor Cable (Pressure Sensors, 4-conductor)
C. Sensor Cable (SubDrives, 2-conductor) X2
D. Mounting Brackets
E. Outdoor Rated 120 VAC/12 VAC Transformer
F. Transformer Output Cable
G. Rubber Plug
H. Installation Manual
Installation Manual
SubDrive Duplex
Alternator
A
B
C
D
F
E
G
H

4
SubDrive Duplex Alternator
4 5
How It Works
The Franklin Electric SubDrive Duplex Alternator is designed to be part of two
independent SubDrive systems. Below is an example of a typical Alternator
System.
Alternating SubDrive Systems
The Alternator controls which drive is running the system by determining which
pressure sensor each drive sees. The two pressure sensors in the system must
have at least a 3 psi differential. The drive that uses the high set sensor will be in
control of supplying water to the system. The other drive will be on the lower set
sensor and will act as a backup. In the event that the primary drive cannot keep
up with the water demand, the backup drive will automatically start and provide
additional water. After the primary drive has reached its dened amount of run
time, the Alternator will interchange the pressure sensors, thus causing the two
drive units to switch roles.
System Diagnostics
In addition to alternating the two drive systems, the Alternator monitors the
two systems to see if they are meeting the water demand as expected. If a
system is not meeting the water demand as expected, the Alternator will lock
the remaining system in as the primary system, declare a ash code indicating
what kind of fault was found, close the alarm contacts, and not allow further
alternation until the fault is cleared.
Pressure Sensors
SubDrive 1 SubDrive 2
Pressure Sensor
Cables
Duplex Alternator
Motor Cables
SubDrive Pressure
Sensor Connections
Pressure Tank
To Power Supply To Power Supply
(see Quick Reference Guide on
pg. 8 for more detail on plumbing)

6
SubDrive Duplex Alternator
6
Fail Safe Operation
The Alternator is designed so that both SubDrive units are always linked to one
pressure sensor or the other. If the Alternator should fail, the system will turn into
a lead-lag system without the alternate function. Therefore, water will still
be delivered even if the Alternator should fail.
Additional Features
The Alternator has a manual override button for selecting which SubDrive unit
should be the primary system. The Alternator also has four different (push
button) selectable timing modes ranging from 1 hour to 24 hours. These timing
modes are based on the run time of the SubDrive unit. When a unit has run
the selected amount of time, the Alternator automatically interchanges the
primary and backup systems. In addition, the Alternator can be used with any
combination of SubDrive products from Franklin Electric; one model ts all!
s WARNING
!
For the indoor/outdoor transformer note the following:
Risk of fire. If installation involves running wiring through a building
structure, special wiring methods are needed. Consult a qualied electrician.
Not for use with dimmers.
Before Getting Started
s ATTENTION
!
This equipment should be installed by technically qualied personnel.
Installation must comply with Franklin Electric’s recommendations, national
and local electrical codes. Failure to do so may result in electrical shock,
re hazard, unsatisfactory performance, or equipment failure. Installation
information is available through pump manufacturers and distributors, or
directly from Franklin Electric at our toll-free number 1-800-348-2420.
s CAUTION
!
Use the SubDrive Duplex Alternator only with Franklin Electric SubDrive
units as specied in this manual (see Table 1). Use of this unit with Variable
Frequency Drives (VFDs) from other manufacturers may result in damage to
both sets of electronics.

6
SubDrive Duplex Alternator
6 7
Controller Location Selection
The following recommendations will help in the selection of the proper location
of the Alternator unit.
1. A tee is recommended for mounting the two pressure sensors at
one junction. If a tee is not used, the pressure sensors should
be located within 6 feet (1.8 meters) of the pressure tank to
minimize pressure uctuations. The distance between the
pressure sensors should be kept to a minimum. There should be
no elbows between the tank and the pressure sensors.
2. The unit should be mounted on a sturdy supporting structure
such as a wall or supporting post.
3. When installed properly, the Alternator enclosure is suitable for
indoor or outdoor installations (see Installation Procedure section
for details pg. 9).
4. The Alternator should only be mounted with the wiring end
oriented downward. The controller should not be placed in
direct sunlight.
5. The mounting location should have access to 115 VAC electrical
supply. For outdoor installations the indoor/outdoor transformer
must be connected to a GFCI outlet and follow all National,
State, and Local electrical codes. Ensure that requirements of
NEC 406.8 are met.
6. To assure maximum weather protection, the unit must be
mounted vertically with the cover snaps engaged.
CORRECT INCORRECT
Sensor Cables from
Pressure Sensors
Power Supply
from Transformer
Sensor Cables to Drives
Sensor Cables from
Pressure Sensors
Power Supply
from Transformer
Sensor Cables to Drives

8
SubDrive Duplex Alternator
8
Quick Reference Guide SubDrive Duplex Alternator
Tank Pre-charge
Inflation Valve
Pressure Gauge Pressure
Sensor
(To Residence)
Pressure
Relief Valve
Discharge into
drain rated for
max pump output
at relief pressure.
Drain Valve
Sensor Cable
Supplied
Pump 1 Pump 2
Motor 1
PRESSURE
SENSORS
12 VAC DRIVES
1212
PS-HI PS-LO SD1 SD2
12 1 2
ALARM
24VAC 1A MAX
24 VDC 0.5A MAX
Drive Sensor
Cables
GFCI Outlet
Drive 2
Drive 1
Motor 2
To
Power
Source
To
Power
Source
Outdoor outlet cover
for outdoor use
Motor Cable
Motor Cable
*Pressure
Sensor
*
* When installing an Alternator with a
SubDrive 300, do not hook up the pressure
shut-off sensor to the Alternator. Only hook
up the pressure sensors to the Alternator.

8
SubDrive Duplex Alternator
8 9
Installation Procedure
1. Disconnect electrical power at the main breaker.
2. Drain the system (if applicable).
3. Install the two SubDrive or Inline units per their installation instructions.
4. Install the two pressure sensors on a tee downstream of the
pressure tank (the pressure tank should be between the pressure
sensors and the pump). The sensors have a ¼-18 National Pipe
Thread (NPT) connection.
5. Mount the Alternator unit in a suitable location using four
mounting screws (not included) as shown in Figure 1 below.
Figure 1: Mounting Screws
Mounting Screw Locations
(User Supplied Quantity 4)
Rear View
Front View
Note: For installation procedures for the Duplex Inline Constant Pressure
System refer to the Duplex Inline Constant Pressure System Quick Reference
Guide (Appendix 1).

10
SubDrive Duplex Alternator
10
Wiring Connections
1. Verify that the power has been shut off at the main breaker.
2. Open the cover to the Alternator.
3. Drive Connections
Connect a two-conductor pressure sensor cable from Drive 1 to the
Alternator’s terminal block labeled SD1 on the right side. The red and
black wire connections are interchangeable. (See Figure 2 below).
Whichever Drive unit is connected to the SD1 terminal will be the primary
system rst. The Drive unit connected to the SD2 terminal will be the
backup system rst.
A. If connecting to a SubDrive300, use the supplied two-conductor
pressure sensor cable. Cut the terminals off both ends of the red
and black leads from the existing four-conductor cable. Leave
only the Green and White leads linking the pressure shut-off
switch to its connections on the SubDrive300.
B. For all other SubDrives, cut off the quick connect ends and strip
the wire to make a two-conductor cable with stripped leads at
both ends.
4. Repeat step 3 for Drive 2, but connect Drive 2’s pressure sensor cable to
the Alternator’s terminal block labeled SD2 on the right side.
Figure 2: Drive Sensor Cable Connections
PRESSURE
SENSORS
12 VAC DRIVES
1212
PS-HI PS-LO SD1 SD2
12 1 2
ALARM
24V-1A
SubDrive
12
ON
1234
SW1
Alternator
PRESSURE
SENSORS
12 VAC DRIVES
1212
PS-HI PS-LO SD1 SD2
12 1 2
ALARM
24V-1A
Alternator
SubDrive300
PRESSURE
SENSOR SHUT-OFF
SW2 SW1
To Pressure Shut-off Switch
PRESSURE
SENSORS
12 VAC DRIVES
1212
PS-HI PS-LO SD1 SD2
12 1 2
ALARM
24V-1A
Alternator
SubDrive300
PRESSURE
SENSOR SHUT-OFF
INT
FAN
INV
FAN
PFC
FAN
NO NO
COM
RELAY
SW2 SW1
O
N
(Cut Black and Red wire on both end only if using SubDrive300)
To Pressure Shut-off Switch
(Cut black and red wires; leave only
the green and white connected to
the pressure shut-off switch.)
Note: If using a NEMA 4 the quick connects or stripped leads may be used.
(A) (B)