SubMonitor Motor Protection System
The SubMonitor Motor Protection System represents the ultimate in protection for the three phase
submersible motors used in the Giant Fountain. The submersible motor and the SubMonitor system
are both manufactured by Franklin Electric.
Digital electronics has made it possible to develop a unique programmed system capable of detecting
overloads, underloads, overvoltage, undervoltage, unbalanced currents, chattering contacts, and
phase reversal. Operates with the Subtrol-equipped submersible motor to provide motor overheat
protection. SubMonitor turns off the submersible motor when any of these faults occur and provides
a visual display of the fault condition and status which is recorded in the system’s history. When the
Giant Fountain is in operation the SubMonitor monitors and displays the three phase voltages, three
phase currents, and the pump status.
The SubMonitor Motor Protection System will come prewired and programmed in the Giant Foun-
tain Power Control Center from the factory. The programming can be verified by following the
“Quick Guide to Setup” section in the Franklin SubMonitor Installation & Operation Manual. See
Table 1 for the settings of each motor rating.All other programmable settings should remain at the
default settings.
Additional contents of the Franklin SubMonitor Installation & Operation Manual are as follows:
- Password Protection
- Event History
- Key Parameters in Event History
- Other Features
- Troubleshooting
WARNING: This equipment should be installed by a technically qualified electrician in compliance
with national and local electrical codes.
Before Installing the SubMonitor System
1. Read both manuals thoroughly.
2. Be sure the incoming power supply is turned off before working on motor or controls.
WARNING: SubMonitor is NOT compatible with phase converters, reduced voltage starters or
variable-speed inverter drives.
WARNING: The Warranty is VOID if the SubMonitor program settings are changed without first
consulting with Otterbine.

Page 5
SubMonitor Settings (Table 1)
HP
7.5
7.5
10
10
15
15
25
25
Voltage
230
460
230
460
230
460
230
460
Hz
60
60
60
60
60
60
60
60
SFAmps
24.6
12.3
32.2
16.1
47.4
23.7
75.0
37.5

Page 6
Limited 3 Year Warranty
Otterbine® Product
Giant Fountain with SubMonitor System
WARRANTY: Barebo, Inc 3840 Main Road East, Emmaus Pennsylvania 18049,U.S.A. hereby
warrants, subject to the conditions hereinbelow set forth, that should the OTTERBINE product
prove defective by reason of improper workmanship or materials at any time during the warranty
period the Purchaser at retail will be guarantee that BAREBO will repair or replace the said
OTTERBINE product as may be necessary to restore it to satisfactory operating condition, with-
out any charge for materials or labor necessarily incident to such repair or replacement, provided
that:
a) The enclosed Warranty Registration Card should be mailed to BAREBO within
fifteen (15) days of the original receipt by the Purchaser at retail in order to avoid delays:
b) The OTTERBINE product must be delivered or shipped, prepaid, in its original
container or a container offering an equal degree of protection, to BAREBO or a
facility authorized by BAREBO to render the said repair or replacement services
or, if purchased from an authorized OTTERBINE dealer, to such dealer;
c) The OTTERBINE product must not have been altered, repaired or serviced by
anyone other than BAREBO, a service facility authorized by BAREBO to render
such service, or by an authorized BAREBO dealer, and the serial number of the
OTTERBINE product must not have been removed or altered: and
d) The OTTERBINE product must not have been subjected to lightning strikes and
other Acts of God, vandalism, freezing-in, accident, misuse or abuse, and must have
been installed in conformance with applicable electrical codes (including proper
electrical protection), and also installed, operated and maintained in accordance with
guidelines in the Owner's Manual shipped with the Otterbine product.
No implied warranties of any kind are made by BAREBO in connection with this OTTERBINE
product, and no other warranties, whether expressed or implied, including implied warranties of
merchantability and fitness for a particular purpose, shall apply to this OTTERBINE product.
Should this OTTERBINE product prove defective in workmanship or material, the retail
Purchaser's sole remedy shall be repair or replacement as is hereinabove expressly provided and,
under no circumstances, shall BAREBO be liable for any loss, damage or injury, direct or conse-
quential, arising out of the use of, or inability to use, the OTTERBINE product, including but not
limited to retail Purchaser's cost, loss of profits, goodwill, damages due to loss of product or
interruption of service, or personal injuries to Purchaser or any person.

Installation & Operation Manual

400 E. Spring Street
Bluffton, IN 46714
Tel: 260-824-2900
Fax: 260-824-2909
www.franklin-electric.com

1
Contents
SubMonitor Submersible
Pump Motor Protection System............................................2
Components ...........................................................................3
Installation............................................................................4-5
Quick Guide to Setup .............................................................6
Additional Programmable Options .......................................7
Password.................................................................................8
Event History...........................................................................9
Key Parameters in Event History ........................................ 10
Other Features...................................................................... 11
Special Conditions ............................................................... 11
Programmable Options........................................................ 12
Troubleshooting.................................................................... 13
Specifications ....................................................................... 14
Mounting Dimensions .......................................................... 15
Notes ..................................................................................... 16

2
SubMonitor Submersible
Pump Motor Protection System
Franklin’s SubMonitor is an easy to use, programmable protection device
for Franklin Electric three phase submersible motors.
SubMonitor’s features provide advanced protection for submersible motors:
• SubMonitor operates over the full range of three phase motor
voltages, 200 - 575 volts, 50 and 60 Hz.
• Operates on motors with service factor current rating of 3 amps
through 359 amps - no external current transformers required.
• Protects motors and pumps from overloads, underloads,
overvoltage, undervoltage, unbalanced currents, chattering contacts,
and phase reversal.
• Operates with a Subtrol-equipped submersible motor to provide
motor overheat protection.
• Monitors and displays three phase voltages, three phase currents,
and pump status.
• When a fault occurs, displays the fault conditions and status.
• Records and displays the history of up to 502 fault trip events, plus
records changes to programmable parameters.
• Records total pump operating time.
• Features a detachable display unit which may be mounted on the
front of a panel for viewing operating status.
• Includes the option of password protection to avoid tampering.
• Easy mounting with DIN rail mounts.
• Totally integrated unit - current transformers are built in.
Simple Programming
SubMonitor has been pre-programmed with default settings for submersible
motors and pumps. Set-up is as simple as setting the motor ratings - voltage,
Hertz, and SF max amps.
Additional programming options can be selected if desired to customize the
features and levels of protection. See page 7 for an overview of the menu
structure and page 12 for a full list of programmable options.
All programming set-up can be made prior to installing at the field site by
connecting 230 volts single phase between voltage inputs L1 and L3 of
SubMonitor and entering the motor data and any other options.

3
Components
4 Line
Digital Display
Fault LIght (Display)
Menu Selector
Switch
Alarm Circuit
Terminals
Control Circuit
Terminals
Reset Switch
Inputs (L1, L2, L3)
Fault Light (Base)
Detachable Display Unit
Base Unit
Integrated Sensor Coils
Plug-in Wiring Connectors