Fraser XIFOS 33 Manuale utente

XIFOS33
OPERATING
INSTRUCTIONS
WITH INTEGRATED REMOTE MONITOR


3
XIFOS33OI-Iss.3-EN
Contents Page
1 Introduction .............................................4
2 Safety ....................................................6
3 PositioningoftheBar....................................7
4 Installation..............................................10
5 ElectricalConnections..................................11
6 StatusLEDs .............................................14
7 OperationandControl..................................15
8 Commissioning .........................................18
9 Maintenance............................................18
10 Troubleshooting ........................................19
11 RemoteInterfaceandWiringExamples ...............20
12 SpecificationandDimensions ..........................24
13 CertificationandCEDeclarationofConformity .......25
14 SparePartsandAccessories ............................26
Fraserstaticcontrolequipmenthasbeendesignedtogive
youmanyyearsofproductiveservice.However,thescience
ofstaticcontrolhasuniquerules,whichmustbefollowedto
allowtheequipmenttogiveagoodreturnonyourinvestment.
Pleasereadthefollowingoperatingandmaintenance
instructionscarefully.
Contents

4© Fraser Anti-Static Techniques Ltd 2020
TheXIFOS33barisoneoftherangeofhighperformanceDCstaticeliminators
fromFraserAnti-StaticTechniques.Theseproductsareusedbyleading
manufacturersthroughouttheworldtoincreasesafetyandproductivity.
Itisessentialthatyoureadandunderstandthecompletemanualbeforeinstalling
andusingthisequipment.Thisisimportantforsafetyandforwarrantycover.
Features and Benefits
TheFraserXIFOS33isahigh-performancebardesignedforlong-range
neutralisationofelectrostaticallychargedsurfaces.
Poweredby24VDC,itfeaturesintegratedhighvoltagesuppliesmeaningthatno
highvoltagecablingisrequired.
1. Introduction
Mountingontothemachineiswith‘T’xings
thatslideintotheslotinthebar.
DistanceControl:distance-to-targetsetting.
See Section 7.
Thestatusofthebar,includingtheneedfor
cleaning,isindicatedby5bi-colourLEDs
ontheendcapofthebar.Duplicateoutputs
enableintegrationwithacontrolsystemor
PLC.SeeSection6.
IntelligenceControl:IntelligenceON/OFF.
See Section 7.
The24VDCpowersupplyandremote
monitoringconnectionsaremadeviaan
M125-pinconnector.
AnexternalAC-DCPSUcanbeorderedif
24VDCisnotavailable.

5
XIFOS33OI-Iss.3-EN
1.1 Explanation of Symbols
Warning!
Thissymbolappearingintheoperatinginstructionsreferstooperationswhich,
ifcarriedoutimproperly,canresultinseriouspersonalinjuries.
Caution!
Thissymbolappearingintheoperatinginstructionsreferstooperationswhich,
ifcarriedoutimproperly,canresultindamagetoproperty.
Information!
Thissymbolreferstoinformationthatrelatestoobtainingthebestperformance
andoperatinglifefromtheproduct.
1.2 Checking on Delivered Equipment
Theequipmentleavesourfactoryinsuitableprotectivepackaging.Pleasecheck
thatitisundamagedwhenitarrives.Ifthereisvisibledamage,contacttheFactory
oroneofourDistributorsbeforecarryingoutanyinstallation.
Checkthatthepartswhichhavebeendeliveredarethesameasyouhaveordered.
LooseParts Barsupto1,000mminlengtharesuppliedwithtwo‘T’xings.
Extra‘T’xingsaresuppliedforeachadditional500mmorpart
thereof.Forexample:
750mm: 2‘T’xings
1,500mm: 3‘T’xings
1,750mm: 4‘T’xings
Itisimportanttouseallofthesupplied‘T’xings.
EmitterKeyandtwospareemitters.
PowerSupplyCable.M125-pinConnectorandleadorPower
SupplyUnit-asperorder.SeeSection14fordetailsofcablesand
otheraccessories.
Warning!
DO NOT USEstandard‘computerstyle’PSUs.Thesedonothavesecondaryearth
connectionsandriskshockstotheoperatoranddamagetothebar.Onlyusethe
FraserexternalPowerSupplyUnit(PartNo.NEOS-PSU).
1. Introduction

6© Fraser Anti-Static Techniques Ltd 2020
TheXIFOS33barhasbeendesignedinaccordancewiththesafetyrequirements
ofEN62368-1:2014.ThisIEC-derivedstandardisharmonisedundertheEULow
VoltageDirectiveandrecognisedbyUL.
• Theemitterpinsareresistivelycoupledtothehighvoltagesupplies.Theemitters
areaClass1electricalenergysource,asdefinedinEN62368-1:2014.Contact
withtheemittersisnotpainfulandwillnotresultinelectrically-causedinjury,but
maycauseadetectablesensationduetothesmallcurrentwhichwillflow.
• AswithallpulsedDCstaticeliminators,itispossiblefortheusertoreceivea
smallstaticshockasaresultoftheirbodybeingchargedbythebar,andthen
dischargingtoanearbyearthedobject.Thisisnotdangerous,butmaybe
uncomfortableandcausesurprise.
• Theemitterpinsofthebararenecessarilysharp.TheemitterpinsareaClass2
mechanicalenergysource,asdefinedinEN62368-1:2014.Contactwith
themmaybepainful,butwillnotcauseaninjuryrequiringemergencymedical
attention.Takecarewhenhandlingthebar.
• Installationandmaintenanceworkonthebarmustonlybecarriedoutby
suitablyqualifiedpersonnel.
• Thenegativepoleofthe24VDCsupplyprovidedtothebarmustbe
permanentlyearthed.
• Adequateinstallationearth/groundisrequiredtoensuresafeandproper
operation.
• DonotconnectordisconnecttheM12cablefromthebarwhileitispowered.
• Asmallamountofozonewillbeproducedaspartoftheionisationprocess.
Wheninstalledcorrectlythelevelofconcentrationofozoneislessthan0.1ppm
andiswithininternationallyacceptedlimits.
• Anychangestotheequipmentwithoutwrittenconsentofthemanufacturerwill
nullifythewarrantyandcertifications.
• Thebarisintendedforuseinindoorfactoryenvironmentsonly.
Itisnotsuitableforoutdooruse.
2. Safety

7
XIFOS33OI-Iss.3-EN
3. Positioning of the Bar
Thebestlocationisat,orimmediatelybefore,theareawherestaticiscausingthe
problem.Rememberthatstaticcanberegeneratedifthematerialpassesover
rollersorthroughaprocessafterneutralising.AStaticMetersuchastheFraser715
isusefultodeterminethebestposition.
Important: Except on a winding reel of material (seetheexamplesonthefollowing
page),thematerialtobeneutralisedmustbeinfreeair,nottouchinganother
surfaceasitpassesthebar.Itisnotpossibletoneutralisestaticelectricitywhere
thematerialistouchinganothersurfaceorroller.
MATERIAL
Incorrect location
Staticneutralisationwillbe
verypoorifthereisnotfree
airoppositethebar.
FREE AIR
MATERIAL
Good location
Freeairopposite
thebarallowsgood
neutralisation.
ü
û

8© Fraser Anti-Static Techniques Ltd 2020
Generally,witharewindorunwind,itisdesirabletousealong-rangebartocope
withthechanginggeometrysothatyoucanneutralisethereelfromthecoretothe
nisheddiameterattheendofthewind.
Thereisanoptimumlocationtoneutralisethereel,whichisshownbythefollowing
diagrams.
TheprincipleistoneutralisethelmAFTERitleavesthenalrollerandasitjoins
thereel.
Ifthereisalay-onorcontactroller(C),thebestpositionfortheXIFOS33isonthe
sidewherethelmleavesthelay-onroller-inthiscasetheunderside(A)-because
itcanneutralisethechargeassoonasitiscreated.Ifthisisnotpractical,then
positionthebaronthetopside.(B)
Lay-on or Contact Roller Example
3. Positioning of the Bar

9
XIFOS33OI-Iss.3-EN
OnacentrewindertheXIFOS33maybepositionedaboveorbelowthereel.Itisa
goodideafortheionisationtobedirectedmainlyatthereel,butalsocatchingthe
singlesheet,asshownat(A).Position(B)isalsoacceptable.
Itisoftennotpossibletoplaceabarintheoptimumposition(A).Thereasonforthis
maybethattheidealbarlocationwouldgetinthewayoftheloading/unloading
processforthereelsorwouldbeinapositionwhereoperatorsmightstandonit.
Inadirtyordustyenvironment,itisbettertoplacethebarfacingdown,sincethe
faceofthebarwillnotbecoveredbythedust.Thisisnotaproblem.Itispossibleto
positionthebaratotherpositions,suchas(B)andstillachieveaverygoodresult.
Wealwayssaythatalmwebmustbein‘freeair’andnottouchingarollerto
achievegoodneutralisation.Thisisbecauseweknowthatthechargeonthe
materialwilltemporarilycombinewiththerollerandnotbeavailableforremoval
bytheeliminator.Thisremainstrue.However,onceyouhaveanumberoflayers
onareelorwinder,allwiththesamepolarityofchargeonthem,thechargecanno
longercombineandcanthereforebeneutralisedlayerbylayer.
Centre Winder Example
3. Positioning of the Bar

10 © Fraser Anti-Static Techniques Ltd 2020
4. Installation
• Useallofthe‘T’fixingsprovidedformountingthebar.The‘T’fixingsslideinto
theslotinthebaseofthebar.Whenmountingthebar,the‘T’fixingsmustbe
evenlydistributedalongthelengthofthebar.Donotallowmorethan800mmof
unsupportedbarbetween‘T’fixings.
• Thebarmustbedryandoil-free.
• Onlymountthebarwiththeslottouchingthemachineorthemountingbracket.
• Whenmountingtothemachineoronabracket,makesurenometalextends
beyondtheslotinthebar.Seethediagrambelow.
Note:Longbarsneedcarefulhandlingduringinstallationtoavoiddamage.
Barslongerthan2,000mmmustbehandledbytwopeople.
Areatobefreeofall
groundreferences
R=min.300mm
• Itisimportantthattheemitterpinsarenottouching,orclosetometalobjects,
toavoidsparkerosionthatwilldamageboththebarandthemetalobject.
• Thedistancefromthematerialshouldbe:250-1,500+mm.
Correct mounting
bracket position
ü
Incorrect mounting
bracket position
û