Fubag B3600B/50 CM3 Manuale utente

B3600B/50 CM3
Горячая линия FUBAG
тел.: (495) 641-31-31
www.fubag.ru
Operator's Manual
Инструкция по эксплуатации
Air compressor
Ременной компрессор
B3600B/50H CM3
B3600B/100 CM3
B3600B/100H CM3
B4800B/100 CT4
B4800B/100H CT4
www.fubag.ru

Omperator's anual
www.fubag.ru
- 1 -
Before use, read the handbook carefully.
Перед тем, как приступить к работе,
внимательно прочитайте инструкцию по
эксплуатации.
Warning, hot surfaces
Опасность ожога
Obligatory eye protection
Обязательная защита органов зрения
Danger - automatic control (closed loop)
Опасность автоматического включения
Dangerous voltage
Опасное напряжение
Power
Мощность
Tank capacity
Объем ресивера
Air intake
Производительность
Max. pressure
Максимальное давление
Revolutions / min. (rpm)
Кол-во оборотов в минуту
Voltage and frequency
Напряжение и частота
Weight
Масса

Omperator's anual
www.fubag.ru
--2

www.fubag.ru
Omperator's anual
- 3 -

www.fubag.ru
Omperator's anual
- 4 -

www.fubag.ru
Omperator's anual
- 5 -

www.fubag.ru
Omperator's anual
1.
-
-
-
-
-
-
-
-
-
-
The compressor must be used in a suitable environment (well ventilated with an ambient
temperature of between +5°C and +40°C) and never in places affected by dust, acids, vapors,
explosive or flammable gases.
Always maintain a safety distance of at least 4 meters between the compressor and the work
area.
Any coloring of the belt guards of the compressor during painting operations indicates that the
distance is too short.
Insert the plug of the electric cable in a socket of suitable shape, voltage and frequency
complying with current regulations.
Use extension cables with a maximum length of 5 meters and of suitable cross-section.
The use of extension cables of different length and also of adapters and multiple sockets should
be avoided.
Always use the switch of the pressure switch to switch off the compressor or use the switch of
the electric panel for models equipped with this. Never switch off the compressor by pulling out
the plug in order to avoid restart with pressure in the head.
Always use the handle to move the compressor.
When operating, the compressor must be placed on a stable, horizontal surface to guarantee
correct lubrication.
Position the compressor at least 50 cm from the wall to permit optimal circulation of fresh air and
to guarantee correct cooling.
Safety perationo
The ’s value measured at4minfree field corresponds to the
’s value stated on the yellow label located on the compressor, minus
20 dB.
acoustic pressure
acoustic power
- 6 -
WARNING! BEFORE USING THE READ THE INSTRUCTION
MANUAL CAREFULLY! FOR QUALIFIED AND SPECIALLY TRAINED PERSONS
ONLY AFTER PROPER READING OF THIS MANUAL IS ALLOWED TO USE AND TO
MAINTAIN THIS .
COMPRESSOR
COMPRESSOR
The detailed description, safety rules and all required information necessary for proper operation
and maintenance of FUBAG are provided below. Keep this instruction manual by
machine and refer to it by any doubts concerning safety operation, maintenance storage and
handling of FUBAG .
compressor
compressor

Not to do:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-P
-A
-
-
-
Never direct the jet of air towards persons, animals or your body. (Always wear safety
goggles to protect your eyes from flying objects that may be lifted by the jet).
Never direct the jet of liquids sprayed by tools connected to the compressor towards the
compressor.
Never use the appliance in your bare feet or with wet hands or feet.
Never pull the power cable to pull the plug out of the socket or to move the compressor.
Never leave the appliance exposed to adverse weather conditions (rain, sun, fog,
snow).
Never transport the compressor with the reservoir pressurized
Never weld or machine the reservoir. In the case of faults or corrosion, replace it
completely.
Never allow inexpert persons to use the compressor. Keep children and animals away
from the work area.
Never position flammable or nylon or fabric articles close to and/or on the compressor.
Never clean the compressor with flammable liquids or solvents. Clean with a damp cloth
only, after making sure that you have unplugged the compressor.
The compressor is designed only to compress air and must not be used for any other
type of gas.
The compressed air produced by the compressor cannot not be used for
pharmaceutical, food or hospital purposes except after particular treatments. It is not
suitable for filling the air bottles of scuba divers.
Never use the compressor without guards (belt guard) and never touch moving parts.
To avoid overheating of the electric motor, this compressor is designed for intermittent
operation as indicated on the dataplate (forexample, S3-50 means 5 minutes ON and 5
minutes OFF). In the case ofoverheating, the thermal cutout of the motor trips,
automatically cutting off the power when the temperature is too high due to excess
current takeoff.
To facilitate machine restart, it is important not only to carry out the operations indicated
but also to set the button of the pressure switch, returning this to the OFF position and
then ON again (figures 1a-1b).
ress the reset button on the terminal box of themotor (fig. 2).
re fitted with a pressure switch equipped with a delayed closing air vent valve (or with a
valve located on the check valve) that facilitates motor start-up; therefore a few-second
jet of air from this, with the reservoir empty, is to be considered normal.
To guarantee machine safety, all the compressors are fitted with a safety valve that is
activated in the case of failure of the pressure switch (fig. 4).
When connecting an air-powered tool to a hose of compressed air supplied by the
compressor, interruption of the flow of air from the hose is compulsory.
Use of the compressed air for the various purposes envisaged (inflation, air-powered
tools, painting, washing with water-based detergents only, etc.) requires knowledge of
and compliance with the rules established for each individual use.
www.fubag.ru
Omperator's anual
- 7 -

www.fubag.ru
Omperator's anual
- 8 -
2. Technical pecificationss
3. Start-up and use
-
-
-
-
-
-
-
-
-
-
-
-
Fit the wheels and foot (or the caster wheel for models that are fitted with this) according to the
instructions provided in the packaging. For versions with fixed feet, assemble the front bracket kit or
the vibration-dampers if furnished. Check that the rating data match the effective characteristics of
the system (voltage and power).
Check for correspondence between the compressor plate data with the actual specifications of the
electrical system.Avariation of ± 10% with respect of the rated value is allowed.
Insert the power plug in a suitable socket checking that the button of the pressure switch located on
the compressor is in the “O” (OFF) position (figures 5a-5b-5c-5d).
Check the oil level using the sight glass and if necessary unscrew the vent plug and top up. (figures
6a-6b).
At this point, the compressor is ready for use.
Operating on the switch of the pressure switch (or the selector for versions with electric panel,
(figures 5a-5b-5c-5d), the compressor starts, pumping air in the reservoir through the delivery
hose.
The absence of pressure in the head facilitates subsequent restart. When air is used, the
compressor restarts automatically when the lower calibration value is reached (approx. 2 bar
between upper and lower). The pressure inside the reservoir can be checked on the gauge
provided (fig. 4).
The compressor continues to operate automatically with this work cycle until the position of the
switch of the pressure switch (figures 5a-5b-5c-5d) is modified. To use the compressor again, wait
at least 10 seconds after this has been switched off before restarting.
Only the wheel-mounted compressors are fitted with a pressure reducer (in the versions with fixed
feet, it is usually installed on the use line). Air pressure can be regulated in order to optimize use of
air-powered tools operating on the knob with the valve open (pulling it up and turning it in a
clockwise direction to increase pressure and counterclockwise to reduce this) (fig. 7). Once you
have set the value required, push the knob down to lock it.
The value set can be checked on the gauge (for versions equipped with this, fig. 8).
Please check that the air consumption and the maximum working pressure of the pneumatic tool to
be used are compatible with the pressure set on the pressure regulator and with the amount of air
supplied by the compressor.
When you have finished working, stop the machine, pull out the plug and empty the reservoir.
The manufacturer reserves himself the right to make the manual's content or function change
without any preliminary notification of the users.
B3600B/50(H) CM3 B3600B/100(H) CM3 B4800B/100(H) CT4
770х340х670 (800х340х670)
55 (57)
950х390х760 (980х390х760)
67 (69)
1065х440х835 (1080х440х850)
71 (73)
360 360

www.fubag.ru
Omperator's anual
- 9 -
4. Maintenance
-
-
-
-
-
-
-
-
-
must be disposed of
The service life of the machine depends on maintenance quality.
PRIOR TO ANY OPERATION SET THE PRESSURE SWITCH TO THE OFF POSITION, PULL
OUTTHE PLUGAND COMPLETELYDRAIN THE RESERVOIR.
Check that all screws (in particular those of the head of the unit) are tightly drawn up (fig. 9). The
check must be carried out prior to the first compressor starting.
Clean the suction filter according to the type of environment and in any case at least every 100
hours. If necessary, replace the filter (a clogged filter impairs efficiency while an inefficient filter
causes harsher wear on the compressor (figures 10a - 10b).
Change the oil after the first 100 hours of operation and subsequently every 300 hours. Check the
oil level periodically.
Never mix different grade oils. If the oil changes color (whitish = presence of water; dark =
overheated), it is good practice to replace the oil immediately.
After topping up, tighten the plug (fig. 11) making sure that there are no leaks during use. Once a
week, check the oil level to assure lubrication in time (fig. 6a).
Periodically (or after completing work if for more than an hour), drain the condensate that forms
inside the reservoir due to the humidity in the air (fig. 12) in order to protect the reservoir from rust
and so as not to restrict its capacity.
Periodically, check the tension of the belts which must have a flexion of around 1 cm (fig. 13).
* Spent oil and condensate in compliance with protection of the environment
and current legislation.
Questo manuale è adatto per i seguenti modelli
5
Indice
Lingue:
Altri manuali Fubag compressore d'aria

Fubag
Fubag Wood Manuale utente

Fubag
Fubag HANDY AIR SP 200 Manuale

Fubag
Fubag BRICO Manuale utente

Fubag
Fubag HANDY AIR OL 195 Manuale utente

Fubag
Fubag VDC 400/50 CM3 Manuale utente

Fubag
Fubag OL 195/24 CM1,5 Manuale utente

Fubag
Fubag B2800B/50 CM3 Manuale utente

Fubag
Fubag VCF/50 CM3 Manuale utente

Fubag
Fubag DC 320/24 CM2,5 Manuale utente

Fubag
Fubag F1 241/24 CM2 Manuale utente