Furuno IC-307 Manuale utente

SHIP SECURITY
ALERT SYSTEM (SSAS)
USCG Version
IC-307
OPERATOR'S MANUAL
www.furuno.com
Model
(For FELCOM 15/16/18/19)

The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9 52 Ashihara cho,
Nishinomiya, 662 8580, JAPAN
A
:
AUG
2005
.
Printed in Japan
All rights reserved.
D
:
JAN
.
23, 2015
Pub. No.
OME-56352-D
(
GREG
)
IC-307(USCG ersion)
0 0 0 1 5 7 1 6 0 1 3

i
TABLE OF CONTENTS
SYSTEM CONFIGURATION ..................................................................................... ii
1. OVERVIEW OF SSAS .......................................................................................... 1
2. INSTALLATION .................................................................................................... 3
2.1 Mounting ........................................................................................................................... 3
2.1.1 Junction box (for FELCOM 16/19) ........................................................................... 3
2.1.2 SSAS alert unit......................................................................................................... 4
2.2 Wiring................................................................................................................................ 6
2.2.1 Junction box (for FELCOM 16/19) ........................................................................... 6
2.2.2 SSAS alert unit......................................................................................................... 7
2.3 Enabling USCG Version ................................................................................................... 8
3. OPERATION ......................................................................................................... 9
3.1 Operation Mode ................................................................................................................ 9
3.1.1 Changing the password............................................................................................ 9
3.1.2 SSAS manager mode ............................................................................................ 10
3.2 Setting SSAS Report Destination and Message Contents ..............................................11
3.3 Transmitting SSAS Report.............................................................................................. 15
3.4 Testing the Button ........................................................................................................... 16
3.5 SSAS Report Test........................................................................................................... 20
4. WATERPROOFING KIT...................................................................................... 21
OUTLINE DRAWINGS........................................................................................... D-1
INTERCONNECTION DIAGRAMS.........................................................................S-1

ii
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.
FELCOM 15
Printer
PP-510
ANTENNA
UNIT
IC-115
TERMINAL UNIT
IC-215
JUNCTION
BOX
IC-315
Navigator
100-115/200-230 VAC
1, 50/60 Hz
: Standard Supply
: Option
: Local Supply
12-24 VDC
AC-DC Power Supply
PR-240-CE*1
*1 Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.
Personal
Computer
(PC/AT compatible)
EGC Printer
PP-505
Shipboard LAN (Ethernet)
GPS receiver
OP16-24
Mini Keyboard
DGPS
Distress Alert/
Received Call Unit
IC-305
Alarm Unit
IC-306
24 VDC
Printer
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
(Max. 3 units)
24 VDC
24 VDC
SSAS Alert Unit
IC-307
FELCOM 16
: Standard
: Option
: Local Supply
PRINTER
ANTENNA
UNIT
IC-116
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
AC-DC
Power Supply
PR-240-CE*1
PERSONAL
COMPUTER
(PC/AT compatible)
POWER
I
O
INMARSAT MINI-C MOBILE EARTHSTATION
FURUNO
POWER
LOGIN
TX
ERROR
JUNCTION BOX
IC-315
100-115/200-230 VAC
1, 50/60 Hz
12-24 VDC
24 VDC
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
(Max. 3 units)
SSAS Alert Unit
IC-307

iii
FELCOM 18
PC
For 12 VDC power,
DC-DC converter is
required to use PP-510.
AC-DC Power Supply
PR-240
TERMINAL
UNIT
IC-218
ANTENNA
UNIT
IC-118
12/24 VDC
Mini keyboard
5139U
Printer
PP-510**
SSAS Alert Unit
IC-307
SSAS Alert Unit
IC-307
Max. 3 units
Shipboard LAN
(Ethernet)
Navigator
JUNCTION BOX
IC-318 Distress Alert/
Received Call Unit
IC-305/IC-350
Alarm Unit
IC-306
GPS Board
OP16-62
(built-in)
SSAS Alert Unit
IC-307
DGPS
FELCOM 19
ANTENNA
UNIT
IC-119
PERSONAL
COMPUTER
(Windows OS)
COMMUNICATION UNIT IC-219
(with internal GPS receiver)
SHIP'S MAINS
12-24 VDC
AC-DC
Power Supply
PR-240
JUNCTION BOX
IC-318
SSAS ALERT UNIT
IC-307*
SSAS ALERT UNIT
IC-307*
* At least two SSAS Alert Units
are required.
NAVIGATOR
(GLONASS
compliant)

1
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/18 or the Inmarsat Mini-C FELCOM 16/19 for the purpose of alerting specified
addresses (for example, your ship’s company) that your ship is under attack by intruders.
The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01
July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
USCG station
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.

2
SSAS operation flow
1.Open the cover and press button one second.
SSAS report is immediately transmitted.
2.An LES sends acknowledgement to your ship.
3.SSAS report is automatically sent to multiple addresses if applicable.
4.Repeated transmission of the SSAS report begins.The interval at
which to transmit the SSAS report to each address can be specifed.
The SSAS report is continuously transmitted at the interval selected.
5. To cancel repeated transmission:
Terminal unit: Turn off the communication unit. Press and hold down
the button on the SSAS unit while turning on the communication unit.
Release the button when the test mode starts. (The FELCOM 16 goes
into the button test mode.)
Note that if there are any unsent messages they are sent and then the
system goes into normal operation; namely, the test mode is not
activated.
PC: Open the SSAS manager (see page 10) and input the command
TERMINATE SSAS ALERT.

3
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16/19)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16/19; it is
already installed on the FELCOM 15/18.
Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.
IC-315 IC-318
Standard compass: 1.0 m Standard compass: 0.90 m
Steering compass: 0.70 m Steering compass: 0.90 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
120
0.5
70
0.5
Junction box IC-315/318
The junction box is connected to the communication cnit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.

4
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.
Standard compass: 0.70 m
Steering compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Rotate
Fasten three screws.
Clamp
4. Run the cable thru one of the cable entrances and connect it to terminal board.

5
5. Attach the switch cover as shown below. Note that the cover may also be rotated 180
degrees.
Switch cover
Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name Type Code No. Qty Remarks
Fixture 16-018-7201-1 100-317-931 1
Pan head screw M3x6 000-800-362 4
Self-tapping screw 4x16 000-802-080 4
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Furuno Sistema di sicurezza

Furuno
Furuno BR-500 Manuale utente

Furuno
Furuno FB-3101 Manuale utente

Furuno
Furuno BR-500 Manuale utente

Furuno
Furuno SSAS Manuale utente

Furuno
Furuno BR-500 Manuale utente

Furuno
Furuno felcom15 Manuale utente

Furuno
Furuno BR-1000 Manuale utente

Furuno
Furuno BR-1000 Manuale utente

Furuno
Furuno FELCOM16 Manuale utente

Furuno
Furuno IC-350 Manuale utente
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente