Galcon G.S.I DC Manuale operativo

G.S.I
DC Controller
Installation & User Guide
January 2015

© 2012-2014 Galcon. All rights reserved.
Information in this documentation is subject to change without notice
and does not represent a commitment on part of Galcon. The software
described in this document is subject to the license agreement that is
included with the product, which species the permitted and prohibited
uses of the product.
Any unauthorized duplication or use of this documentation, in whole or
in part, in print, or in any other storage or retrieval system is prohibited.
No part of this publication may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language
in any form by any means for any purpose other than the purchaser’s
personal use without the permission of Galcon.
Contact Us
Galcon
Kfar Blum 1215000, Israel
Tel: 972-4-6900222
Fax: 972-4-6902727
E-mail: [email protected]
Visit us at: www.galconc.com
G.S.I web application: www.gsi.galconc.com

2
Table of Contents
1Introduction.................................................................... 6
G.S.I Controller Models ........................................................6
2Setting Up the G.S.I Controller........................................ 7
Installing the Controller .......................................................7
Installing on a Wall or in a Control Cupboard ................7
Installing on a Pole .................................................. 10
Establishing the Electrical Connections................................. 12
Connecting the Solenoids to the Controller (Outputs)... 13
Inserting Batteries ............................................................ 14
Connecting a Rain Sensor, Flow Meter, and Fertilizer Meter .... 16
Inserting a SIM Card ......................................................... 16
3On-Site Controller Operation......................................... 19
Main Screen Features ........................................................ 19
Establishing Communication with the Server ........................ 22
Manually Setting the Controller Clock .................................. 23
Testing Station Operation................................................... 23
Creating an Irrigation Program ........................................... 25
Setting Irrigation Program Durations ......................... 26
Setting the Irrigation Cycle Time ............................... 27
Setting the Irrigation Start Day and Time ................... 29
Cancelling an Irrigation Program Start ................................. 31
Initiating Manual Irrigation for a Station............................... 32
Resetting the Controller ..................................................... 33

3
Pausing and Resuming Irrigation from the Controller ............. 34
Fault Indication................................................................. 35
Locking and Unlocking the Screen ....................................... 36
4Technical Specifications .................................................39

4
List of Figures
Figure 1: Open Controller Cover ...................................................8
Figure 2: Control Panel Swung Outward.........................................8
Figure 3: Opening the Internal Casing ...........................................9
Figure 4: Mounting Screw Holes on Back of Unit .............................9
Figure 5: Mounting Screw Holes Dimensions ..................................9
Figure 6: Inserting the Mounting Screws........................................9
Figure 7: Removing the Pole Mounting Brackets ........................... 10
Figure 8: Upper Bracket Reorientation ......................................... 10
Figure 9: Lower Bracket Reorientation ......................................... 11
Figure 10: Correctly Oriented Pole Mounting Brackets ................... 11
Figure 11: Pole Mounting Bands Inserted in Brackets .................... 12
Figure 12: Output Connectors Labeled B and R............................. 13
Figure 13: Battery Compartment Removed ..................................14
Figure 14: SIM Card Case .......................................................... 17
Figure 15: SIM Card Insertion Orientation.................................... 18
Figure 16: Correctly Inserted SIM Card........................................ 18
Figure 17: Main Screen.............................................................. 20
Figure 18: Reception Test Screen ............................................... 23
Figure 19: Test Screen .............................................................. 24
Figure 20: Test Sequence Screen................................................ 24
Figure 21: Stop Test Sequence Screen ........................................ 25
Figure 22: Fertilizer Test Screen ................................................. 25
Figure 23: Duration Screen Example ........................................... 27
Figure 24: Cycle Screen............................................................. 28
Figure 25: Twelve Hour Cycle Setting Example ............................. 28

5
Figure 26: Six Day Cycle Setting Example.................................... 29
Figure 27: Start Day Screen Example.......................................... 29
Figure 28: Start Time Screen ..................................................... 30
Figure 29: OFF Screen............................................................... 30
Figure 30: OPEN Screen –immediate cycle start .......................... 31
Figure 31: Manual Irrigation Screen ............................................ 32

6
1 Introduction
The Galcon G.S.I Controller commands the irrigation valves in the field.
It is connected wirelessly to the G.S.I web application that enables
programming the controller remotely.
Creating irrigation programs for the G.S.I Controller is primarily done
from the G.S.I web application. However, you can also create a simple
irrigation program directly on the controller even before setting up the
web application. You can also perform manual irrigation directly from
the controller.
This manual describes how to install the G.S.I Controller, test to verify
successful installation, perform basic, initial irrigation programming, and
perform manual valve irrigation. For information on using the G.S.I web
application, see the G.S.I web application online help available at:
www.gsi.galconc.com enter with your user name and password and
click the icon.
G.S.I Controller Models
There are two models of the G.S.I Controller, based on the type of
power supply used:
DC unit (pre-installed with a Lithium pack 14.4 V) or rechargeable
batteries.
AC unit.
This document describes the DC unit type.

G.S.I DC Installation and Operation Guide
7
2 Setting Up the G.S.I Controller
Setting up the G.S.I Controller system includes the following tasks:
Installing the Controller (see below)
Establishing the Electrical Connections (see page 12)
Installing the Controller
The controller is designed to withstand outdoor installation conditions
(at a rating of IP64). However it is preferable to provide additional
protection from the climate by installing it in a sheltered position.
Appropriate installation of the controller will ensure dependable
operation throughout the years.
The controller can be installed in two ways:
Installation on a wall or in a control cupboard.
Installation on a metal pole of 1¼” to 1½” diameter.
Installing on a Wall or in a Control Cupboard
To install the controller on a wall or in a control cupboard:
1. Unlock and open the controller cover (Figure 1).
2. Swing out the control panel (Figure 2).

G.S.I DC Installation and Operation Guide
8
3. For the internal casing on the right side, unscrew the two screws
and open the casing (Figure 3). Mount the controller to the wall or
to the control cupboard through the marked holes (Figure 4 and
Figure 5) with the aid of three screws. Close the screws by hand
only.
4. Close the internal casing and fasten its screws.
5. Swing the control panel back into place.
6. Close and lock the controller cover.
Figure 6: Open Controller Cover
Figure 7: Control Panel Swung
Outward

G.S.I DC Installation and Operation Guide
9
Figure 8: Opening the Internal Casing
Figure 9: Mounting Screw
Holes on Back of Unit
Figure 10: Mounting Screw Holes
Dimensions
Figure 11: Inserting the Mounting Screws
Indice
Altri manuali Galcon Controllori

Galcon
Galcon 11000BT Manuale utente

Galcon
Galcon 61 Series Manuale utente

Galcon
Galcon S Series Manuale utente

Galcon
Galcon 7001D Manuale utente

Galcon
Galcon Gal Pro DC Manuale utente

Galcon
Galcon AC 4 Manuale utente

Galcon
Galcon DC-11SF Manuale utente

Galcon
Galcon Galileo Manuale utente

Galcon
Galcon Dc-1 Manuale utente

Galcon
Galcon Galileo Manuale