Gallagher S400 Manuale utente

PORTABLE SOLAR
FENCE ENERGIZER
S0
Instructions
Installatie instucties
Notice d’installation
Betriebsanleitung
Monteringsvejledning
Instrucciones
Monteringsinstrucktioner
Istruzioni per l’installazione
- ENG
- NED
- FRA
- DEU
- DAN
- ESP
- SVE
- ITA

PUBLISHED BY
Gallagher Group Limited
Kahikatea Drive, Private Bag 3026
Hamilton, New Zealand
www.gallagher.com
Copyright © Gallagher Group Limited 2021.
All rights reserved. Patents Pending.
Gallagher S400 Portable Solar Fence Energizer User Manual for animals
Électrificateur de clôture pour animaux
3E4097 - Edion 7 - June 2021
DISCLAIMER Whilst every effort has been made to
ensure accuracy, neither Gallagher Group Limited
nor any employee of the company, shall be liable
on any ground whatsoever to any party in respect
of decisions or acons they may make as a result
of using this informaon.
In accordance with the Gallagher policy of
connuing development, design and specificaons
are subject to change without noce.
Developed and manufactured by Gallagher Group
Limited, an ISO 9001:2000 Cerfied Supplier.


3
3E4097 Gallagher S400 Solar Energizer User Manual
English
IMPORTANT INFORMATION
WARNING
WARNING - Do not connect to mains-operated
equipment.
• WARNING - The appliance is not intended for use by young
children or inrm persons without supervision.
• Young children should be supervised to ensure that they do
not play with the appliance.
• Regularly inspect the supply cord, cables, wires and
energizer for any damage. If found damaged in any way,
immediately cease use of the energizer and return it to a
Gallagher Authorised Service Centre for repair in order to
avoid a hazard.
• It is recommended that, in all areas where there is a likely presence of unsupervised children who will be
unaware of the dangers of electric fencing, that a suitably rated current liming device having a resistance of
not less than 500 ohms be connected between the energizer and the electric fence in this area.
• Do not use the energizer with non-rechargeable baeries.
• Refer servicing and replacement baeries to a Gallagher Authorised Service Centre.
• Check your local council for specic regulaons.
• Fence wiring should be installed well away from any telephone or telegraph line or radio aerial.
• Well maintained electric fences kept clear of vegetaon with high quality insulaon are extremely unlikely to
cause res. In mes of extreme re risk, disconnect energizer.
• Electric animal fences shall be installed and operated so that they cause no electrical hazard to persons,
animals or their surroundings.
• Do NOT become entangled in the fence. Avoid electric fence construcons that are likely to lead to the
entanglement of animals or persons.
• WARNING - INSTALLERS/USERS SHOULD NOTE: Avoid
contacng the fence with the head, mouth, neck or torso. Do not
climb over, through or under a mul-wire electric fence. Use a gate or
a specially designed crossing point.

4
3E4097 Gallagher S400 Solar Energizer User Manual
• An electric animal fence shall not be supplied from two separate energizers or from independent fence circuits
of the same energizer.
• For any two separate electric animal fences, each supplied from a separate energizer independently med, the
distance between the wires of the two electric animal fences shall be at least 2.5m. If this gap is to be closed,
this shall be eected by means of electrically non-conducve material or an isolated metal barrier.
• Barbed wire or razor wire shall not be electried by an energizer.
• A non-electried fence incorporang barbed wire or razor wire may be used to support one or more o-set
electried wires of an electric animal fence. The supporng devices for the electried wires shall be constructed
so as to ensure that these wires are posioned at a minimum distance of 150 mm from the vercal plane of the
non-electried wires. The barbed wire and razor wire shall be earthed at regular intervals.
• Follow the energizer manufacturer’s recommendaons regarding earthing.
• Do not install an earth (ground) system for your electric fence within 10 m (33 ) of any power,
telecommunicaons or other system.
• Use high voltage lead-out cable in buildings to eecvely insulate from the earthed structural parts of the
building and where soil could corrode exposed galvanized wire. Do not use household electrical cable.
• Connecng leads that are run underground shall be run in conduit of insulang material or else insulated high
voltage lead-out cable shall be used. Care must be taken to avoid damage to the connecng leads due to the
eects of animal hooves or tractor wheels sinking into the ground.
• Connecng leads shall not be installed in the same conduit as the mains supply wiring, communicaon cables
or data cables.
• Connecng leads and electric animal fence wires shall not cross above overhead power or communicaon lines.
• Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided it
shall be made underneath the power line and as nearly as possible at right angles to it.
• If connecng leads and electric animal fence wires are installed near an overhead power line, the clearances
shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Power line Voltage V Clearance m
Less than or equal to 1 000 3
Greater than 1 000 and less than or equal to 33 000 4
Greater than 33 000 8
• If connecng leads and electric animal fence wires are installed near an overhead power line, their height
above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projecon of the outermost conductors of the power line on
the ground surface, for a distance of:
-2 m for power lines operang at a nominal voltage not exceeding 1 000 V;
-15 m for power lines operang at a nominal voltage exceeding 1 000 V.
• Electric animal fences intended for deterring birds, household pet containment or training animals such as cows
need only be supplied from low output energizers to obtain sasfactory and safe performance.
• In electric animal fences intended for deterring birds from roosng on buildings, no electric fence wire shall be
connected to an earth stake. A warning sign shall be ed to every point where persons may gain ready access
to the conductors.

5
3E4097 Gallagher S400 Solar Energizer User Manual
English
• Where an electric animal fence crosses a public pathway, a non-electried gate shall be incorporated in the
electric animal fence at that point or a crossing by means of sles shall be provided. At any such crossing, the
adjacent electried wires shall carry warning signs.
• Any part of an electric animal fence that is installed along a public road or pathway shall be idened by
electric fence warning signs (G6020) at regular intervals that are securely fastened to the fence posts or
rmly clamped to the fence wires.
• The size of the warning sign shall be at least 100mm x 200mm.
• The background colour of both sides of the warning sign shall be yellow. The inscripon on the sign shall be
black and shall be either:
-the substance of “CAUTION: Electric Fence” or,
-the symbol shown:
• The inscripon shall be indelible, inscribed on both sides of the warning sign and
have a height of at least 25mm.
• Ensure that all mains operated, ancillary equipment connected to the electric animal
fence circuit provides a degree of isolaon between the fence circuit and the supply
mains equivalent to that provided by the energizer.
• Protecon from the weather shall be provided for the ancillary equipment unless this equipment is cered
by the manufacturer as being suitable for use outdoors, and is of a type with a minimum degree of protecon
IPX4.
This energizer complies with internaonal safety regulaons and is manufactured to internaonal standards.
Gallagher reserves the right to make changes without noce to any product specicaon to improve reliability,
funcon or design. E & OE.
The author thanks the Internaonal Electrotechnical Commission (IEC) for permission to reproduce Informaon from its
Internaonal Publicaon 60335-2-76 ed.2.2 (2013). Annex BB-1.All such extracts are copyright of IEC, Geneva, Switzerland.
All rights reserved. Further informaon on the IEC is available from www.iec.ch. IEC has no responsibility for the placement
and context in which the extracts and contents are reproduced by the author, nor is IEC in any way responsible for the other
content or accuracy therein.

6
3E4097 Gallagher S400 Solar Energizer User Manual
1Baery
indicator
Green Baeries OK
Green
Flashing
Baeries charging
Red Baeries need charging. See "Tips &
Troubleshoong" (p. 9).
2Power Switch - Baery check
- OFF
- Pest control mode
- Livestock control mode
3Light Sensor Used by the energizer to determine if it is day or night
4Solar Panel Keep clean so baeries will charge from the sun
5Earth Terminal Connects to earth/ground stake
6Fence Terminal Connects to fence
OVERVIEW
6
5
7
8
1
2
4
9
10
3

7
3E4097 Gallagher S400 Solar Energizer User Manual
English
7Voltage
Indicator
Green pulse Fence Voltage is OK
Red pulse Fence voltage is low. See "Tips &
Troubleshoong" (p. 9).
8Baery Access Undo screw to access baeries
(Baeries need connecng before rst use)
9Steel Post
Mount
Allows for 360o mounting on T-Post, Y-Post or similar
10 Y-Post Mount
Note: Approvals & Standards - FCC
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protecon against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instrucon
manual, may cause harmful interference to radio communicaons. Operaon of this
equipment in a residenal area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
CAUTION:
Do not install energizer on the ground. x
!

8
3E4097 Gallagher S400 Solar Energizer User Manual
1. Open the energizer
Note: Before connecng the baeries
ensure the Power switch is in the
posion.
4. Install energizer
The solar panel should face
towards the equator. i.e. in the
northern hemisphere, panel faces
south, in the southern hemisphere,
panel faces north. Avoid placing in
5. Connect leads
a) Connect green terminal to
earth stake at least 3 (90cm)
into ground.
b) Connect red terminal to fence
line.
6. Switch energizer ON
INSTALLATION INSTRUCTIONS
3’ Earth Rod
GREEN
RED
Altri manuali per S400
2
Indice
Lingue:
Altri manuali Gallagher Recinzioni e cancelli





















