Galvin Engineering Flowmatic TZ-IQWAVEB Manuale utente

Version 1, 25th March 2020 Page 1of 6
Flowmatic®Wave On Activated Concealed Sensor
With Solenoid, Battery Powered
PRODUCT CODE:
- TZ-IQWAVEB
TECHNICAL DATA
Inlet
½” BSP – Female
Outlet
½” BSP - Male
Headwork
Solenoid
Battery (VDC)
6
Solenoid
Input Voltage
6.75V DC
Power Consumption
-
Cable length
3.2m
Pressure Range (kPa)
Min
50
Max
500
Temperature (°C)
Min
5
Max
80
Finish
SS Faceplate
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
SENSOR DETAILS
•Hardware
Varox 4.2.2
•Software
IQ7VARIR2V 7.15-0256, release 15.5.2015
•Input Voltage
6.75V DC –0.5A
•Cable length
3.2m
•Sensor function
Standard washbasin (with proximity sensor)
•Preset line purge feature interval:
12 hours after last flush, water flow duration 3 min
•Preset continuous run:
5 min
•Sensor range:
Sensor1 and Sensor2 custom made steps
TOOLS REQUIRED
−Power drill
−Spanner or adjustable crescent
−Screw driver

Version 2, 8 April 2020, 2 of 6
Version 1, 25th March 2020 Page 2of 6
DIMENSIONS
−A cavity must be supplied to fit sensor on the back of faceplate as shown, minimum 20mm deep.
−Drill 2 x mounting 6.0x30 deep holes, location as shown.
Note: See below for a typical installation of the sensor position from basin.
Typical Installation
Wall Plugs & Cut-out Details

Version 2, 8 April 2020, 3 of 6
Version 1, 25th March 2020 Page 3of 6
INSTALLATION
INSTALLATION COMPLIANCE: Galvin Specialised products must be installed in accordance with these installation
instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical
supply conditions must also comply tothe applicable national and/or state standards. Failing to comply with these provisions
shall void the product warranty and may affect the performance of the product.
1. Fit solenoid
−Before installation, all lines must be flushed. We
recommend that a line strainer be installed prior
to the solenoid to eliminate any foreign material.
−Ensure the solenoid is mounted using the 2
anchor points shown and is in a suitable
location.
−Connect mains water and the outlet using
thread tape/sealant.
2. Fit faceplate
−Before fitting the faceplate refer to the Dimensions
section to ensure a suitable location has been selected
for correct operation.
−Fit the supplied wall plugs following the Dimensions
section.
−Ensure the faceplate is orientated correctly. On the rear
of the face plate (pictured) is a sticker indicating the
correct orientation.
−Fit and secure the faceplate using the supplied screws
and tool.
Do not remove the black label covering the
sensor until the tap is to be commissioned.
3. Fit connections and test
−The extension cable can be used for either the battery or the solenoid.
−Connect the solenoid to either of the male connections on the rear of the sensor and the battery to the female
connection (as shown).
−Remove label covering the sensor.
−Start sensor; Refer to the following section –Sensor Setting Instructions
−Check for any leaks and correct operation.
Water
Out
Water In
Anchor
Point
Face Plate Rear View

Version 2, 8 April 2020, 4 of 6
Version 1, 25th March 2020 Page 4of 6
SENSOR SETTING INSTRUCTIONS
Signs
and
symbols
Touch function
Hand/object within sensor area
Water flows
LED flashes Green
Water flow stops
LED flashes Red
H –hours / min. –minutes / sec. - seconds
FUNCTION
PROCEDURE
FEEDBACK
SIGNAL
INFORMATION
DEFAULT
SETTING
RANGE
Via IQUA
Touch
First startup
After
installation
1x app. 4 sec. till
Remove hand/object from sensor
area
-.
-
wait
+
2x/sec., keep out of sensor
area
wait till
1x
Confirmation, ready for operation
Temporary
off
«Cleaning
mode»
Activate
1x app. 2 sec. till
1x
Extended function mode is active
2 min.
2x a app. 0.5 sec
Pulsing during active function
Temporary
off
Stop
1x app. 2 sec.
1x
Manual stop
or automatic
1x
Automatic after preset time
Continuous
run
Activate
1x app. 2 sec. till
1x
Extended function mode is active
5 min.
0.5-20 min.
(in 0.5
steps
)
min.
1x minimum 3 sec.
(max. 5 sec.)
Water flows after releasing
Continuous
run
Stop
1x app. 2 sec.
Manual stop
or automatic
Automatic after preset time
Follow up
Time control
For normal
operation
Set / program
1x app. 2 sec. till
1x
Extended function mode is active
1 sec.
0-10 sec.
1x app. 5 sec. till
1x
1x 0 - 10 sec.
Keep touched
+
1x/sec., water flows during
touching - releasing defines
duration
after releasing
1x
Confirmation, ready for operation
XXX
XXX
XX
X

Version 2, 8 April 2020, 5 of 6
Version 1, 25th March 2020 Page 5of 6
Time of water
flow For
continuous
run
1x app. 2 sec. till
1x
Extended function mode is active
5 min.
0.5-20 min
(in 0.5 min
steps)
1x minimum 3
sec. (max. 5 sec.)
+
Touch max. 5 sec., water flows
after releasing, number of (1x-
40x) shows current setting
1x keep touched
till
1x - 40x
1x =0.5 min. .... 40x = 20.0
min.
releasing defines duration
after releasing
+
1x
check / confirmation of setting by
repeating number of (1x - 40x)
according to setting
line purge
feature
activate /
deactivate
<< Automatic
flush on set
interval>>
(time of
waterflow: 3
min)
1x app. 2 sec. till
1x
extended function mode is active
12h
Off
12 h
24 h
48 h
1x app. 25 sec. till
1x - 4x
1x= off,
2x=12h,
3x= 24h,
4x= 48h
ignore flashes after 5 sec.
and 10 sec. –keep touched till
1x - 4x after app. 25 sec.,
releasing defines interval
Wait till
1x
Confirmation, ready for operation
restart
electronics
1x app. 2 sec. till
1x
extended function mode is active
2x a app. 0,5 sec
pulsing during active function
1x app. 5 sec. till
4x
1x/sec.
Release and wait till
+
1x/sec., keep out of sensor
area
Wait till
1x
confirmation, ready for operation
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Sensor Not Responding
−Damaged or scratched lens
−Sensor length to short
−Lead damaged
−No power
−Waving hand too fast
−Replace the sensor unit
−Adjust beam to correct length.
−Replace connected item.
−Check power is on or replace battery
−Slow down the action in front of the
sensor
False Activation
−Sensor length too long
−Reflection from a light source
−Adjust sensor length to correct length
−Re-align sensor or shield light source
Water is not flowing
from outlet
−Water is off
−Solenoid isn’t activating
−Turn on mains water
−Remove and check the solenoid for debris.
Clean and re-install. Replace solenoid if faulty.

Version 2, 8 April 2020, 6 of 6
Version 1, 25th March 2020 Page 6of 6
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty
Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.
Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but
not limited to the implied warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer’s warranty available for download
from www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free
from operational defects in workmanship and materials for the warranty period as shown on the schedule in
the manufacturer’s warranty. During the warranty period, Galvin Engineering will replace or repair any
defective products manufactured by Galvin Engineering without charge, so long as the terms of the
Manufacturer’s warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for
breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other
property which is damaged if this product does not work properly, other costs resulting from labour charges,
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions,
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or
alteration of the product.
Indice
Altri manuali Galvin Engineering Accessori

Galvin Engineering
Galvin Engineering CliniMix CMV2 Foglio di istruzioni

Galvin Engineering
Galvin Engineering CliniMix CMV2 Foglio di istruzioni

Galvin Engineering
Galvin Engineering CliniMix CMV2 Foglio di istruzioni

Galvin Engineering
Galvin Engineering Flowmatic TZ-FLOWSENC24B Manuale utente

Galvin Engineering
Galvin Engineering CliniMix CMV2 Foglio di istruzioni

Galvin Engineering
Galvin Engineering CliniMix Lead Safe 100.30.79.00 Foglio di istruzioni