Example Monitor Trace:
PV> Checksum 66A8, code revision B01f
Menu Choice D: Download Intel HEX Code from EPROM to Serial Port
Menu Choice F: Firmware Upload from Serial Port using Intel HEX Format
The CFtoSCSI card has a Flash PROM installed. In order to update the code on this
PROM, the card needs to be connected to the serial port on a PC and the code
downloaded, as follows.
1 Run Procomm or a Terminal Emulator of your choice.
2 Set Baud rate to 19.2 K, no parity, 8 data bits, one stop bit.
3 Switch on PV card. Reset message will appear together with ‘Enter a
“CONTRO -Z” to invoke the Diagnostic Mode!”
4 Get the PV Diagnostic Utility, and select ‘F - Firmware upload from serial
port using INTE HEX format’.
Example Monitor Trace:
PV> F
Firmware upload using Intel HEX transfer.
Backing up FLASH in case serial transfer fails !
To stop the transfer press ESCAPE if using PROCOMM then
press ^C to restore FLASH and reset PG card.
Relocating Code...
Amd Device - 16k Programmed Okay
Amd Device - 16k Programmed Okay
Amd Device - 16k Programmed Okay
Amd Device - 16k Programmed Okay
Validating Code...
5 Message appears ‘Start your ASCII upload of the HEX file now’:
HEX ADDR = 0000
6 Initiate upload - selecting ASCII transfer (filename ******.HEX).
7 When complete ADDR = FFFF, then Checksum test is carried out.
If Checksum test passes, board is reset.
If Checksum test fails, backup of code is restored at the end of the PROM
and the old code is restored for use (if one line fails during upload, then need
to
exit transfer and old code will be restored).
Example Monitor Trace:
Amd Device - 16k Programmed Okay
Amd Device - 16k Programmed Okay
Amd Device - 16k Programmed Okay
This option is available for use by Garson Industries Personnel only.