GasQuip GQ-CWS Manuale utente

CYLINDER WEIGHT SCALE GQ-CWS
INSTRUCTIONS

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
2
TABLE OF CONTENTS
1.
MECHANICALCONSTRUCTIONS 3
1.1 Outline dimensions 3
2.
BATTERY INSTALLATIONINSTRUCTIONS 4
3.
ELECTRICAL CONNECTIONS 5
4.
KEY FUNCTIONS 6
4.1 Tare/Zero/lb to kg conversion 6
FUNCTION 7
7
7
7
5.MENU 8
5.1 Structure of the Menu 8
5.2 Access to Main Menu . 9
5.3 Change numeric parameter . 9
5.4 Change Maximum capacity of the Scale ...10
5.5 Settings .12
5.6 Calibration Settings 14
5.7 Filters and Motions 16
5.8 Functions 18
6.CALIBRATIONPROCEDURE 19
7.Accessories 20
7.1 Battery Charger 20

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
3
1.
MECHANICALCONSTRUCTIONS
1.1 Outlinedimensions
All Dimensions are in Inch[mm]

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
4
2.
BATTERY INSTALLATIONINSTRUCTIONS
Remove battery cover as below image.
Verify battery polarity as labeled in battery holders.
Lithium-Ion 3.7V button-top rechargeable 18650 Batteries are recommended.
https://www.18650batterystore.com/products/samsung-35e-button-top

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
5
3.
ELECTRICAL CONNECTIONS
Use only provided battery charger to charge the Lithium-Ion 18650 rechargeable batteries. Using other
charger or power supply can cause damages to the scale.

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
6
4.
KEY FUNCTIONS
Below table describe the basic functionality of the scale keypad when they are using in the two main
Key
Weighing Display
functionality Menu Display functionality
Menu/SELECT Move to Menu Select an item
ZERO/ UP Set Scale ZERO
Move UP.
When entering number, the key is used to
increase the number by 1
Tare/ DOWN Set Scale Tare
Move DOWN.
When entering number, the key is used to
decrease the number by 1.
Back/Left/Lb to kg Conversion lb to kg
conversion.
When entering number, the key used to
move to right digit.
4.1 Tare/Zero/lb to kg conversion

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
7
4.2
that available in the menu.
4.3
Set the system zero - this function will crea
-
-
- this function will return the zero point to that which was
, will return the
4.4
Set the tare point - this function will activate the net weighing function, by storing the current
-
the net weighing mode, and restores the current zero. The weighing signal output returns to the gross
4.5
Initially the Scale has been calibrated to lb unit and by default it shows the output in lb. Once press the
Once the lb/kg conversion button is pressed, the unit of measure that will be converted is shown before
the scale output.

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
8
5. MENU
5.1 Structure of the Menu

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
9
5.2 Access to Main Menu
In weighing window, by pressing the Menu button it allows to access to the scale menu and button
functionality has been changed to reach menu functionalities as below.
5.3 Change numeric parameter
When changing the values stored in parameters, it is required to enter some numbers. Once reached to
that kind of function the keypad has been changed as below.

Group Four Transducers
22 Deer Park Drive,
E. Longmeadow, MA 01028
www.groupfourtransducers.com
Phone : (800) 419 1444
Fax : (413) 525 -6182
sales@group-4.com
Rev 0
10
Initially, there are six zeros displayed in this section, and one of them is flashing. The flashing zero is a
changeable digit. /> right digit and begins blinking
that digit. The value of the blinking digit can be c /^ /v Using
the "Select" button, the modified value may then be saved.
5.4 Change Maximum capacity of the Scale
Start with Scale powered on and in normal weighing mode.
1to enter to Menu
2
3
Enter the password
4
5
6
7
Indice