GBD DCD300 Manuale utente

DCD300
DCD300 Waterproof multifunction
keypad
with double relay for
stand-alone access control
USER MANUAL
UK

DCD300
Installation
Material
Programming
Power supply
Absorption at rest
Form of identification
Keypad
PIN lenght
RFID reader
Users number
Alarm output
Wiring connections
Status and programming
LED
Status and programming
acoustic signal
Operating
temperature / RH
Cable lenght
Waterproof rating
Dimensions (l x h x w)
Gross weight
Wall mounting
Metal alloy
By keypad
12/24V ac/dc
< 50mA
Code / Tag RFID or both
12 backlit metallic buttons
1-8 digits
(up to 100.000.000 combinations)
125Khz up to 6cm
1 - 999
Output 0V
Door open too long / Door
forced / Max. no. wrong attempts /
Anti-tampering
Relay output, Exit button,
Alarm, Door Contact,
Doorbell
Green, red, blue, yellow
Buzzer/Beep sound
2 m
IP 66
from -30°C to +60°C / 98% RH
55 x 135 x 24 mm
0,54 Kg
1 - TECHNICAL SPECIFICATIONS
2 - FORM OF IDENTIFICATION
Card/Tag
PIN code
Card/Tag
+ PIN code
Button
Entry of a code (from 1 to 8 digits except
0 and 00000000), then #
Reading of a Card/Tag
Reading of a Card/Tag and entry
of a PIN code associated, then #
Pressure on the keypad button

3 - INSTALLATION
1
2
Install the fixing support
on a
perfectly flat surface
Fix the device on the
fixing support from above,
then pull down
Tighten the device on the fixing
support with the locking screw
DescriptionWires Name
Red
Black
Blue
Blue/Black
Green
Green/Black
White
White/Black
Grey
Yellow
Orange
Brown
Purple (*)
(*) usable only in DC
NO 1
NO 2
NC 1
NC 2
COM 1
COM 2
GND
OPEN 1
OPEN 2
D_IN
Alarm
Power supply 12-24V ac/dc
Power supply 12-24V ac/dc
Normally open Relay 1
Normally open Relay 2
Normally close Relay 1
Normally close Relay 2
Common Relay 1
Common Relay 2
GND
Push button Relay 1 (PTE)
Push button Relay 2 (PTE)
Location contact of the door
Output alarm 0V if on alert
4 - WIRING DESCRIPTION

Grey
Yellow
White
Green
Red
Black
Power supply
12-24 V DC
Diode
1N4004
provided
(**)
Electrical
lock device -
de-energised
to release
+
Clock (*)
Push Button
(PTE) (*)
+
5 - CONNECTION DIAGRAM
5.1 - Electric lock device - de-energised to release
(*) Clock/Push Button (PTE):
Enable relay for "timed relay" (see
chap. 10) or as long as the contact
is closed.
The Push button input does not work
in bistable mode
(**) Diode 1N4004:
To be used only with power supply
in DC

5 - CONNECTION DIAGRAM
5.2 - Electric lock - energised to release
Grey
Yellow
White
Blue
Red
Black
+
+
Power supply
12-24 V DC
Diode
1N4004
supplied
(**)
Electric lock -
energised
to release
Push
Button
(PTE) (*)
(*) Push Button (PTE):
Enable relay for "timed relay" (see
chap. 10) or as long as the contact
is closed.
The Push button input does not work
in bistable mode
(**) Diode 1N4004:
To be used only with power supply
in DC

5 - CONNECTION DIAGRAM
5.3 - Device controlled by a dry contact NO
(*) Push Button (PTE):
Enable relay for "timed relay" (see
chap. 10) or as long as the contact
is closed.
The Push button input does not work
in bistable mode.
Control from dry contact NO
Grey
Yellow
White
Blue
Red
Black
+
Transformer
12-24 V AC/DC
Push Button
(PTE) (*)

5.4 - Connection of a door switch to manage
the alarm if door open too long
and/or door forced (see chap. 10)
5 - CONNECTION DIAGRAM
Brown
Purple
Black
Red
Grey
Power supply
12-24 V DC
+
Buzzer, siren,
flash, relay,...
This output
uses only DC
current
Position
contact
of the door
(closes the contact
when the door
is closed)

6 - FIRST POWER UP
7 - ENTRY IN PROGRAMMING MODE
• At first power up, the blue LED and the Buzzer works for 3s, then
the device switches into “Stand-by” with flashing blue LED.
• The entry of the default PIN 8 8 8 8 8 8 ,then #
enables the relay 1 for 5s (green LED fixed).
WARNING: from the registration of the first user, the default
PIN will no longer be active.
Chap.
Chap.
Chap.
Chap.
1
2
3
yellow LED
yellow LED
*(you have 20s to type enter
the Master code)
Type the Master code
8 8 8 8 8 8 then #
The device is in programming mode, proceed with the
required function:
Users Programming and Cancellation:
• Programming of a PIN code
or a Card/Tag
• Programming of Card/Tag
in succession
• Programming of Card/Tag + PIN
• User/s Cancellation
Advanced functions:
• Relay 1 configuration
• Relay 2 configuration
• Doorbell button configuration
• Keypad backlight
• Buzzer sound volume
• “Door open too long” alarm
• “Door forced” alarm
• Max. no. of wrong attempts alarm
• Anti-tampering alarm
• Back to factory parameters
Chap.
Chap.
Chap.
Chap.
Chap.
Chap.
Chap.
Chap.
Chap.
Chap.
10.1
10.2
10.3
10.4
10.5
11.1
11.2
11.3
11.4
12
.................................
.................................
.....................
........................................
.................................
.........................
.....................................
..............
.................................
........................
LED / Audible beep
Buttons
9.1
9.2
9.3
9.4
.............................................
.............................................
................
....................................
4Blue LED
*to exit from Programming
mode
(a)
(a) Without any action, the device automatically exits from Programming
mode after 60 sec.

Addition of a
Read the Card/Tag or enter
the number of the Card/Tag,
then press #
Card/Tag
(b)
Default Master code = 8 8 8 8 8 8
New Master code = ................................
8 - CHANGE OF DEFAULT MASTER CODE
9 - USERS ADDITION AND CANCELLATION
WARNING: Change the default Master Code at
your first installation.
The device must be in Programming mode, see Chap. 7
The device must be in Programming mode, see Chap. 7
1
2
3
2
Yellow LED
Yellow LED
OK = Green LED
+ 2 Beeps
Error = Red LED
+ 5 Beeps
0 (enables the function)
LED / Audible beep
Buttons
Enter the new Master Code (from 4
to 8 digits, except 0 and 00000000)
then press #
Enter the new Master Code again,
then press #
Enter a User ID from 1 to 999,
then press #
4Yellow LED
OR
Blue LED
Enter another function or press
to exit from Programming mode
1Yellow LED
Yellow LED
LED / Audible beep
Buttons
3Yellow LED
9.1 - ADDITION OF A PIN OR A CARD/TAG
Choose the relay associated to
the User ID chosen: = relay 1,
(a)
or 2 = relay 2 , or
(a)
1 2 = relay 1 and 2 , simulta-
neously, then press #
1
1 1 (enables the function)
4B
OK =
+ 1 Beep
Error = Red LED
+ 5 Beeps
Green LED
4A
OK = Green LED
+ 1 Beep
Error = Red LED
+ 5 Beeps
Addition of a PIN
Enter a PIN (from 1 to 8 digits,
except 0 and 00000000), then
press #
OR

Resume from point 1 to add another user
5
5
Yellow LED
OR
Blue LED
Yellow LED
OR
Blue LED
Enter another function or press
to exit from Programming mode
Enter another function or press
to exit from Programming mode
The device must be in Programming mode, see Chap. 7
The device must be in Programming mode, see Chap. 7
LED / Audible beep
LED / Audible beep
Buttons
Buttons
9.2 - ADDITION OF CARD/TAG IN SUCCESSION
9.3 - ADDITION OF A CARD/TAG + PIN
1
1
Yellow LED
Yellow LED
1 2 (enables the function)
1 5 (enables the function)
2Enter User ID of the 1st user
between 1 and 999, then press #
Yellow LED
3Yellow LED
Choose the relay you must
associate to User ID: 1 = relay 1,
(a)
or 2 = relay 2 , or
(a)
1 2 = relay 1 and 2 , simulta-
neously, then press #
4
OK = Green LED
+ 1 Beep
Error = Red LED
+ 5 Beeps
Read the Card/Tag in succession,
then press #
2Enter a User ID from 1 to 999,
then press #
Yellow LED
3Yellow LED
Choose the relay associated to the
User ID chosen: 1 = relay 1,
or 2 = relay 2 , or
(a)
1 2 = relay 1 and 2 , simulta-
neously, then press #
(a)
4
Press a PIN (from 1 to 8 digits,
except 0 and 00000000), then
press #
Yellow LED
Error = Red LED
+ 5 Beeps
Indice