General tools DAF2005MDL Manuale utente

Air velocity, Air flow, Type K/J thermometer
Real time data logger, 16000 Data logger no., RS232
ANEMOMETER
Model : DAF2005MDL

TABLE OF CONTENTS
1. FEATURES................................................................ 1
2. SPECIFICATIONS...................................................... 2
3. FRONT PANEL DESCRIPTION.....................................6
4. GENERAL MEASURING PROCEDURE........................... 8
4-1 Air velocity/Air temperature measurement............
.
8
4-2 Air flow ( CMM, CFM ) measurement.....................9
4-3 Thermocouple ( Type K/J ) Thermometer
measurement.....................................................
.
10
4-4 Data Hold...........................................................
.
11
4-5 Data Record (Max., Min. reading)......................... 11
4-6 Data Logger........................................................ 12
5. ADVANCED ADJUSTMENT PROCEDURE......................
.
14
5-1 Check Memory Space...........................................15
5-2 Clear Memory......................................................15
5-3 Date/Time Setting...............................................
.
15
5-4 Sample Time Setting............................................16
5-5 Auto Power Off Default Setting.............................16
5-6 Temp. Unit Default Setting...................................16
5-7 Air Velocity Unit Default Setting............................17
5-8 Air Flow Unit Default Setting................................
.
17
5-9 Area Size ( Air Flow ) Default Setting.................... 17
5-10 Escape from the SETTING function..................... 18
6. HOW TO SEND THE DATA OUT FROM THE METER.....
.
18
7. RS232 PC SERIAL INTERFACE...................................
.
21
8. BATTERY REPLACEMENT........................................... 23
9. SYSTEM RESET.........................................................23
10. OPTIONAL ACCESSORIES........................................ 24

1. FEATURES
* Air velocity : m/S, Ft/min, Km/h, Knots, Mile/h,
* Air flow : CMM ( m^3/min. ) and CFM ( ft^3/min. ).
* Air temperature ( , )℃℉
* Type K/ Type J thermocouple thermometer.
* Real time data logger, build in clock ( hour-min.-sec.,
year-month-date ).
* Auto or manual data record, 16,000 Data logger no.
* Wide sampling time adjustment range from two
seconds to 8 hours 59 minutes 59 seconds.
* RS232 computer interface.
* Can default auto power off or manual power off.
* Can default the air velocity, air flow, Temp. unit.
* Air flow measurement can set the area dimension.
* Multi function with easy operation
* Low-friction ball vane wheels make sure high accuracy
in high & low velocities.
* Metal vane, high reliability.
* Large LCD with multiple display.
* Data hold, record max. and min. reading.
* Microcomputer circuit provides special function & offer
high accuracy.
* Air Temp. used thermistor sensor, fast response time.
* Power by UM3 ( 1.5 V ) x 4 batteries or DC 9V adapter.
* RS232 PC serial interface.
* Separate probe, easy for operation of different
measurement environment.
* Wide applications: use this anemometer to check air
conditioning & heating systems, measure air velocities,
wind temperature...etc.
1

2. SPECIFICATIONS
2-1 General Specifications
Circuit Custom one-chip of microprocessor LSI
circuit.
Display LCD size : 58 mm x 34 mm.
Measurement
Air velocity:
Unit m/S (meters per second)
Km/h ( kilometers per hour )
Ft/min ( feet per minute )
Knots ( nautical miles per hour )
Mile/h ( miles per hour )
Air flow:
CMM ( m^3/min., cube meter per min. )
CFM ( m^3/min., cube feet per min. )
Air temperature:
, ℃℉
Type K/ Type J thermometer.
, ℃℉
Sampling Time Manual Push the data logger button
of Data Logger once will save data one time.
@
Set the sampling time to
0 second
Auto 2 sec to 8 hour 59 min. 59 sec.
Sensor
Air velocity & Air flow :
Structure Conventional twisted van arm and low
friction ball bearing design, vane use
metal material.
Air temperature :
Thermistor.
Type K/ Type J thermometer.
Thermocouple
2

Temperature Automatic temp. compensation for the
Compensation Type K/J thermometer.
Data Hold Freeze the display reading.
Memory Recall Maximum & Minimum value.
Sampling Time Approx. 1 second.
of display
Power off Auto shut off saves battery life or
manual off by push button.
Data Output RS 232 PC serial interface.
Operating 0 to 50 .℃
Temperature
Operating Less than 80% R.H.
Humidity
Power Supply DC 1,5 V battery ( UM3 ) x 4 PCs,
* main instrument
( Heavy duty type ).
DC 9V adapter input.
@ AC/DC power adapter is optional.
Power Supply DC 3V silver battery.
* clock module
Type : CR2032.
Power Current Approx. DC 21.5 mA
@ Main instrument.
DC 27.5 mA.
@ Main instrument. + Anemometer probe.
Weight 515 g/ 1.13 LB.
@ Battery is included.
Dimension
Main instrument :
203 x 76 x 38 mm
Anemometer sensor head :
Round, 72 mm Dia.
Accessories Instruction manual.....................
.
1 PC
Included
A
nemometer probe.....................1 PC
DC 3V silver battery, CR2032......
.
1 PC
Carrying case.............................
.
1 PC
3

Optional Type K thermocouple probe.
Accessories AC to DC 9V adapter.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.
Data Logger software, SW-DL2005.
2-2 Electrical Specifications (23± 5 )℃
Air velocity
Measurement Range Resolution Accuracy
m/S 0.4 - 30.0 m/S 0.1 m/S ± ( 2%+0.2 m/S)
Km/h 1.4 - 108.0 Km/h 0.1 Km/h ± ( 2%+0.8 Km/h)
Mile/h 0.9 - 67.0 Mile/h 0.1 Mile/h ± ( 2%+0.4 Mile/h)
Knots 0.8 - 58.3 Knots 0.1 Knots ± ( 2%+0.4 Knots)
Ft/min 80 - 5910 Ft/min 1 Ft/min ± ( 2%+40 Ft/min)
Air flow
Measurement Range Resolution Area
CMM (m^3/min.) 0 to 54,000 m^3/min. 0.001-1 0.001-30.0 m^3/min.
CFM (ft^3min.). 0 to 1,908,300 ft^3/min. 0.01-100 0.01-322.91 ft^3/min.
Air temperature
Measuring Range 0 to 50 /32 to 122 ℃℃℉ ℉
Resolution 0.1 /0.1 ℃℉
Accuracy ± 0.8 /1.5 ℃℉
4

Type K/J thermometer
Sensor Reso- Range Accuracy
Type lution
Type K 0.1 ℃-50.0 to 1300.0 ℃± ( 0.2 % + 0.5 )℃
-50.1 to -100.0 ℃± ( 0.2 % + 1 )℃
0.1 ℉-58.0 to 2372.0 ℉± ( 0.2 % + 1 )℉
-58.1 to -148.0 ℉± ( 0.2 % + 1.8 )℉
Type J 0.1 ℃-100.0 to 1100.0 ℃± ( 0.2 % + 0.5 )℃
-50.1 to -100.0 ℃± ( 0.2 % + 1 )℃
0.1 ℉-58.0 to 2012.0 ℉± ( 0.2 % + 1 )℉
-58.1 to -148.0 ℉± ( 0.2 % + 1.8 )℉
@
Above specification tests under the environment RF
Field Strength less than 3 V/M & frequency less than
30 MHz only.
5

3. FRONT PANEL DESCRIPTION
6

3-1 Display
3-2 Power Button
3-3 HOLD Button ( ESC Button )
3-4 REC Button ( Enter Button )
3-5 Up Button ▲
3-6 Function Button ( Down Button )▼
3-7 Send Button ( Clock Button )
3-8 SET Button ( Logger Button )
3-9 Stand
3-10 Battery Compartment/Cover
3-11 Tripod Fix Nut
3-12 LCD Brightness Adjust VR
3-13 System Reset Switch
3-14 RS-232 Output Terminal
3-15 DC 9V Power Adapter Input Socket
3-16 Type K/J Probe Input Socket
3-17 Probe Input Socket
3-18 Probe Lock Switch ( System On/Off Switch )
3-19 Probe Plug
3-20 Probe head ( Anemometer vane & Temperature )
3-21 Probe handle
7

4. GENERAL MEASURING
PROCEDURE
The meter default value are following :
* The air velocity unit is m/S.
* The temperature unit is .℃
* The air flow unit is CMM.
* The air flow area is meter^2 ( meter square ).
* The sampling time of data logger function is
2 seconds.
4-1 Air velocity /Air Temp. measurement
1)Install the " Probe Plug " ( 3-19, Fig. 1 ) into the
" Probe Input Socket " ( 3-17, Fig. 1 ).
Attention :
After install the " Probe Plug ", should slide
Probe Lock Switch " ( 3-18, Fig. 1 ) to the On
position ( right position ).
2)Power on the meter by pressing the " Power Button "
( 3-2, Fig. 1 ).
3)Select measuring function by pressing " Function
Button " ( 3-6, Fig. 1 ) until the display show the
air velocity unit.
@ Air velocity measurement, the display unit
will show m/S ( or Ft/min, Km/h, Knots, Mile/h ).
@ The Air velocity unit adjustment, please refer
Chapter 5-7.
8