GF Intelek-Pro SIGNET 9010 Manuale utente

+GF+SIGNET 9010 Intelek-Pro
Flow Controller
Instruction Manual
GEORGE FISCHER +GF+
FLOW CONTROLLER
+GF+SIGNET

Danger: Avoid electric shock. Do not connect
power when the instrument cover is partially or
completely removed.
Important safety information

Table of
Contents
Chapter Page
1 Introduction 1
1.1 Introduction 1
1.2 Front Panel Description 2
1.3 Rear Panel Description 3
2 Installation and Operation 4
2.1 Mounting Instructions 4
2.2 Power Connections 5
2.3 Input Connections 6
2.4 Standard Output Connections 7
2.5 Relay Output Connections 8
2.6 Verifying Analog Outputs 9
2.7 Analog Output Connections 10
3 System Configuration 10
3.1 Introduction 10
3.2 Calibration Menu, Frequency Inputs 12
3.3 Calibration Menu, Analog Inputs 12
3.4 2-Relay Operations 15
3.5 Calibration Menu, 2-Relay 16
3.6 Calibration Menu, Analog Outputs 17
3.7 View-Only Menus 18
4 Technical Support 19
4.1 Accessing Internal Options 19
4.2 AC Power Configurations 19
4.3 Installing Input/Output Options 20
4.4 Option Cards and Accessories 21
4.5 Input Card Configuration 22
4.6 Output Card Configuration 23
4.7 Troubleshooting 23
Specifications 24
Warranty Information 26

Unpacking and Inspection
Your flow controller package includes the
following items:
•+GF+SIGNET 9010 Intelek-Pro Flow
Controller
• Two stainless steel mounting brackets
• Mounting Instructions w/self-adhesive
template
• Panel gasket
• Instruction manual w/assorted engineering
labels
Warranty Record
For your protection, record your unit's purchase
information for future reference. The serial
number decal is located on the instrument's rear
panel.
Model: +GF+SIGNET 9010 Intelek-Pro Flow
Controller
Purchase Date: ________________________
Serial Number: _________________________
Purchased From: ________________________
Purchase Order Number: ________________

Chapter 1
Introduction
1.1 Introduction
Your new +GF+SIGNET 9010 Intelek-Pro Flow
Controller has been specifically designed for liquid
flow rate measurement in process pipes. The
controller's compact 1/4 DIN enclosure (front) is
NEMA 4X/IP65 rated and ideal for installing into
instrumentation panels with limited space.
Modular "plug-in" input/output option cards allow
you to customize your flow controller to your flow
system's requirements. The controller's unique
"slide-out" chassis design makes option installation
fast and simple. Smart self-configuring
microprocessor based circuitry automatically
inventories installed options during power-up,
allowing you to upgrade your system in seconds
without the need for additional equipment.
The unit's front panel features a highly visible
4.5- digit (seven segment) and 8-digit (alpha-
numeric) liquid crystal display with adjustable
contrast. Active flow rate, accumulation, and
alarm relay information is quickly accessed at a
glance. During calibration the user is prompted
with clear step-by-step instructions on the unit's front
panel display.
The +GF+SIGNET 9010 Intelek-Pro Flow
Controller is fully compatible with all +GF+Signet
flow sensor products, yet also accepts other
analog inputs, such as 4 to 20 mA or
0 to 5 VDC etc.
The technical data given in
this publication is for general
information purposes only. It
implies no warranty of
whatever kind.
1

5.
Item Function
Indicate activation status of optional output "alarm" relays 1 & 2
8.
Most engineering units and blanks available for custom applications (included).
User selected and installed for specific applications.
1. Relay An-
nunciators:
2. LCD
Display: Shows flow, calibration, accumulation, and relay activation status information
3. A) Accesses one of three calibration menus: CAL, RELAY, OUT B) Enables a
calibration parameter for modification C) Restores a calibration parameter to
it's original value during calibration
A) Stores a calibration value into memory after modification B) Used to display
available input/output options during normal operation.
4.
6. A) Accesses the RELAY "view-only" menu B) Used in conjunction with MOD key
to access the RELAY calibration menu
A) Accesses the OUTPUT "view-only" menu B) Used in conjunction with MOD
key to access the OUTPUT calibration menu
7.
Decreases the value of a selected calibration digit
Increases the value of a selected calibration digit
9.
10. A) Returns the unit to normal operation mode B) Selects a digit for modification
during calibration
11. Unit Tags
A) Accesses the CAL "view-only" menu B) Used in conjunction with MOD key
to access the main CAL menu
MOD
CAL
ENTER
RELAY
OUTPUT
FLOW
FLOW CONTROLLER
ENTER MOD FLOW
CAL RELAY OUTPUT
RLY 1
RLY 2
GPM
2
3
4
5
6
1
7
8
9
10
11
+GF+SIGNET
Item 11:
Remove front bezel
to change unit tags
under clear overlay
window. The unit
tags are attached
to the rear cover
of the manual.
2
1.2 Front Panel Description

Item
17 to 30 VDC system power connection 2. DC IN
1. AC IN
Alarm relay #1 (COM, NO, NC) contact set for external
device control (optional) 3. RLY 1
4. RLY 2
Alarm relay #2 (COM, NO, NC) contact set for external
device control (optional)
6. Sensor
Analog output #1 from option socket #1 (optional) 5. ANL1
Analog signal input connection (optional)
Serial outputs (future availability)
Analog output #2 from option socket #2 (optional) 9. ANL2
8. Serial
7. A in
CNT emits an open collector pulse output for each increment
of totalizer. PLS emits a TTL frequency output in phase with the
sensor input
10. Output
11. SSUnused Terminal
Note:
Rear terminals
accept 18 to 22 AWG
wire
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15 16 17 18 19 20 21 22 23 24 25 26 27 28
SS CNT GND PLS
OUTPUT ANL2
R+ R-
SERIAL
Tx GND Rx
A in
A+ A- BLK RED SHLD
SENSOR
L
1
N
AC IN + GND NO C NC
RLY1DC IN NO C NC
RLY2 R+ R-
ANL1
10 9876
12
345
11
Flow sensor input connection (frequency)
90 to 132 VAC or 180 to 264 VAC system power
connection
Function
3
1.3 Rear Panel Description

2.1 Mounting Instructions
The +GF+SIGNET Intelek-Pro Flow Controller's
1/4 DIN enclosure is specifically designed for
panel mounting. Adjustable mounting brackets
allow mounting in panels up to 1 in./25 mm thick.
An adhesive template and instructions are included
to insure proper installation.
For outdoor and/or stand alone installations the
splash-proof NEMA 4X/IP65 back cover kit is
recommended (ordered separately).
Figure 1
External dimensions
5.7 in./145 mm 6 in./152 mm
7.2 in./183 mm
Mounting Clamp (included, 2 ea.)
*Optional NEMA 4X/IP65 Rear Cover
3.8 in. sq.
96 mm 3.5 in.
88 mm
Mounting Panel
Max. panel thickness = 1 in./25 mm
Panel
Gasket
SIDE VIEW
6.5 in./165 mm
Panel Cutout Instructions
Recommended panel cutout 3.54 in./90 mm square. Maximum panel cutout 3.62 in./
92 mm square, DO NOT exceed. Use adhesive backed template (included)
4
Chapter 2
Installation
and
Operation

2.2 Power Connections
AC Power Connections
Instructions
1. Jumper selectable for 90 to 132 OR 180 to
264 VAC operation. Confirm AC power configuration
before applying power. See section 4.2 pg# 19
2. *A direct or low impedance AC ground (earth
ground) MUST be used for proper operation.
3. To reduce the possibility of noise interference, AC
power lines must be isolated from signal lines.
DC Power Connections
Note: AC/DC power can be connected simultaneously,
using DC power as an uninterrupted power source.
*A direct or low impedance earth ground MUST be used
for optimum performance.
15 16 17 18 19 20 21 22 23 24 25 26 27 28
L
1
N
AC IN
+ GND NO C NC
RLY1DC IN NO C NC
RLY2
R+ R-
ANL1
90 to 132 VAC
OR
180 to 264 VAC
AC Hot
AC Ground*
AC Neutral
5
Figure 2
AC power wiring
Figure 3
DC power wiring
Danger:
Avoid electric
shock. Do not connect power
when the instrument cover is
partially or completely
removed.
DC power is recommended
when ground fault interrupt
devices (GFI's) are used.
L
1
N
AC IN
+ GND NO C NC
RLY1DC IN NO C NC
RLY2
R+ R-
ANL1
17 to 30 VDC @ 0.5 A
GND
15 16 17 18 19 20 21 22 23 24 25 26 27 28
*

SS CNT GND PLS
OUTPUT ANL2
R+ R-
SERIAL
Tx GND Rx
A in
A+ A- BLK RED SHLD
SENSOR
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Analog Input:
Current or Voltage
R+
R-
C
SHIELD
RED
BLACK
A
&
B
External DC
Power Supply -
+
OR
Frequency Input:
for Signet sensors
and others
+GF+
SIGNET
8512
+-
2.3 Input Connections
Four input sources are accepted:
A. Non-isolated Frequency Inputs
Frequency (non-iso) card: Accepts non-isolated,
0 to 10 kHz @ 0.2 Vp-p minimum sine or square
wave signal inputs. This card requires dip switch
configuration prior to operation.
B. Isolated Frequency Inputs
Frequency (iso) card: Accepts isolated, 0 to
10 kHz @ 0.5 Vp-p minimum sine or square wave
signal inputs. No configuration required.
C. Analog Inputs
Two analog input cards are offered:
• Analog (iso) current, 4 to 20/0 to 20 mA
• Analog (iso) voltage, 0 to 5/0 to 10 VDC
Input ranges are software selectable, requiring no
internal configuration.
Note:
See section 4.4
for a listing of available input
cards.
Figure 4
Input Wiring
6
To reduce the possibility of
noise interference, separate
input lines from AC power
lines.