Giltron 9851 Manuale utente

사 용 설 명 서- 영문
MULTI-FUNCTION DATALOGGER
WITH PRINTER
9851, Temp./RH logging printer

INDEX
Introduction
Material Supplied
Features
Comparison table
Meter setting
Single measurement
Multiple measurement
Automatic logging
Diagram
9851 Temp./RH logging printer
Software
File
Mode
Port
Commad
Print
1
1
9
13
14
15
15
16
17
18
...............................
...................................
.........................
.........................
..........................
........................
...............................
.......................
........................................
.......................................
.......................................
...................................
...................................
.......................
..........................
Specification sheet
Trouble shooting
7
8
1
2
.........
3
4
5
6
.........................
.....................
Top cover of meter & Accessory
Meter keypad

This meter designed with three measurement modes:
1)Single point measurement
2)Multiple points measurement ( Manually record)
3)Automatically Logging
INTRODUCTION
MATERIAL SUPPLIED
Features
Check for damaged or missing parts in your meter before starting.
Thank you for purchasing this multiple function printer! This unit
has been developed to meet your max.satisfaction by its user-
friendly design. Please review the entire manual for a complete
overview of how to operate this meter.
The complete meter set should contain
User friendly interface
RS232 cable and software enable to link with PC to download
Backlight function
Tripod mountable for long time use
Power off time selectable
Big Dot matrix LCD
Powered by 4pcs AA batteries or 9V adaptor
Measuring/Programming ....Anywhere, anytime
1
& upload
1. Meter
2. 4pcs AAbatteries
3. Printing Thermo-paper
4. Operation manual
5. Carry Case
6. RH probe (Acalibration data small note enclosed)
7. RS232 cable
8. Software CD
Printing anywhere, anytime

COMPARISON TABLE
Measured parameters of each meter:
MODEL FUNCTION PARAMETERS
2
Temperature,DP
Humidity, Wet Bulb
9851 Hygro-thermometer
Please refer to below for the difference of each measurement mode.
MEASUREMENT DESCRIPTION MEMORY POINT
Single Point
Measurement
Single point
measurement No Memory
Multiple Point
Measurement
File name editable
multiple point
measurement 99 points
Automatic
Logging Programmable
datalogging function 3000 points
Comparison table of multiple points and datalogging measurements
Editable or
Default with date
and time (Note 1)
Default (Note 2)
Press "ON/OFF" key to
measure and store
by pressing specified
keys
MEASURING /
SAMPLING
Automatically measure
and store according to
pre-set parameters
(Note 3)
MULTIPLE POINT
MEASUREMENT DATALOGGING
RECORD 99 points
FILE
NAME
3000 points

Note 1: Eachrecord is designed to show withcurrent date and
time if userdoesn't edit any.
For example if the filename is "05-06 09:21:51" means thedate
is 6th May(or 5th June, based on yourdate mode
setting )and thetime is 09:21:51.
Note 2: Eachrecord is designed to show withthe current date
and time.
Note 3: a)To set upBegin-Date,Start-Time,End-Date,Suspend-
time and samplerate from the meter.
b)Each meter startsto record from Begin-Date & timewith
specified sample rateuntil Suspend-time.
c)Automatically start againnext day from Start-Time until
End-Date.
d)Logging stops recordingwhen End-Date or max.
memory points isachieved.
e)Logging can bestopped and start again with thesame
setting.
3
ACCESSORY The temperature and humidity
sensors are built in theprobe.
Please keep the small piece
of noted enclosed with each
probe for calibration purpose.
The following illustrationis the connectors for 9851.
TOP COVER -CONNECTOR

METER KEYPAD-WITH PRINTER
4
ON/OFF
12
5
8
0
3
6
9
4
7
F2 F3 F4F1
SYM.
GHI
PQRS
DEF
MNO
WXYZ
ABC
JKL
TUV
LINE
FEED
Based on different functions, the
top cover connectorand color are
different. It is dark greenfor 9851.
TopCover
LCD
Keypad
Backlight
Up and Downkeys
Paper Roll cover
Welcome
MEAS MEM LOG SET
Function keys
Corresponding
1SYM stands for"1,*,.,:,$,+,-,="
2ABC stands for"2,a,b,c,A,B,C"
3DEF stands for"3,d,e,f,D,E,F"
4GHI stands for"4,g,h,i,G,H,I"
5JKL stands for"5,j,k,l,J,K,L"
6MNO stands for"6,m,n,o,M,N,O"
7PQRS stands for"7,p,q,r,s,P,Q,R,S"
8TUV stands for"8,t,u,v,T,U,V"
9WXYZ stands for"9,w,x,y,z,W,X,
Y,Z"
0 stands for"0 and space"
DC adaptor port
RS232 Port

LCD Cont.(1-5): LCD brightness. From darkest 1 to brightest 5
Prn Cont. (1-9): Printing darkness. From lightest 1 to heaviest 9
Unit: The unit could be metric or imperial / or
Auto Off: The selectable time frame is 1 to 20 min.
CF
Set Clock: To choose the date mode and set your local time.
Date mode:MM-DD-YY or DD-MM-YY or YY-MM-DD
Set ID: If choose "Disable", the ID will not be printed out.
ID: To edit an ID of this printer , the ID will be printed out at
printing mode.
Descriptions :
Select item: To select which measured parameters need to be
showed on the LCD. The unit of each parameter
could be selected from here as well.
Pressing or key to shift the cursor.
Pressing EDIT to enter modification mode.
Pressing PRN to enter printing mode.
Pressing NEXT/BACK to enter next or previous page.
Pressing EXIT to return to main menu
METER SETTING
Before measuring, pleasecheck the meter setting first toconfirm
the basic settingsof the meter are what youneed.
Toenter each command, just press thecorresponding F1 to F4
key.
F2 F3 F4F1
Welcome
MEAS MEM LOG SET
SET
F4 :Meter Setting
5

There are threemeasurement modes :
1. Single measurement(MEAS)
2. Multiple measurement(MEM)and
3. Autologging (LOG).
Press F1 (MEAS) to proceed single measurement
After entering measurement mode , press F4 (PRN) to enter
printing mode. The printing can be stopped any time by press
F1(STOP or EXIT) key while it is printing .
External temp. & RH probe calibration introduction is in the
Single measurement mode .
Definition
SINGLE MEASUREMENT
MEAS
F1 :Single Measurement
F2 F3 F4F1
Welcome
MEAS MEM LOG SET
6
Operating the singlemeasurement as a general meter.
The printing contrastcan be changed by pressing HIGHor
LOW key .

MULTIPLE MEASUREMENT
This is tomanually record what you measured withreal time
, and filename (a note or identification forthe record ) is edit-
able to memorizeor recognize .
There are total99 memorize capacities in this measurement.
Press MEAS to measure the parameters.
Select F1(ABORT) or F4(SAVE) to exit the measurement
or memory the record .
Press F3 ( Edit ) to edit the file name of recorded value .
While editing the file name, select from the keys 1SYM, 2ABC,
3DEF, 4GHI...., Press and hold one of the key to select from
the displayed letters by releasing the key .
Press CLR shortly to delete one data or press for over 2 seconds
to delete the whole memory.
Before printing, select the printing range by pressing EDIT
key,then press START to print.
Definition
7
F2 :Multiple measurement
MEM
F2 F3 F4F1
Welcome
MEAS MEM LOG SET

AUTOMATIC LOGGING
Press SET to set needed setting first. The Date mode is
based on the mode you set under SET (see page 5). The
sampling rate is from 1 to 7200 seconds. "Expect" means
total memory of this meter, "Remain" means how many
memory left in meter.
Press START to begin the logging function. While logging:
Press VIEW to see the data ( more than one ) in the screen,
or press MEAS to see a real-time data,
or press STOP to quit logging.
Press P-PG or N-PG to review previous or next 100 points.
After stopping, press START to begin again. The sampling rate
and previous record are remained if the previous setting
has not been changed.
"Suspend" is the stop time of each day during setting date.
If you want to record 24 hours a day, you have to set :
00:00:00 as "Start" , and 23:59:59 as "Suspend" .
Definition
F2 F3 F4F1
Welcome
MEAS MEM LOG SET
F3 :Datalogging
LOG
This is toautomatically record what you set upbefore
measurement with realtime, first to set records start/stop
date and time,sample rate , memory points. The screen
content shows Expectmemory points and Remain memory
points while insetting.
8
Indice