GIT GBS-101 Manuale utente

Borescope
GBS-101
User Manual

Patents, trademarks, copyrights, copyrights, and intellectual property rights of this user manual are owned by GIT.
No part or all of this manual may be reproduced or used in any form without written permission of GIT.
Purchase of this user manual does not imply a transfer of patent, trademark, copyright, copyright, or intellectual property rights.
GBS-101 (Wireless Car Endoscope) is a registered trademark of GIT.
All contents and images used in this user's manual may be modified, attached or deleted without notice due to improvement
or improvement of product function and specification.
For products not manufactured by G.I.T CO., LTD, such as tablet PCs, comply with the manufacturer's A / S standards.
In addition to the programs recommended by G.I.T CO., LTD, customers are not entitled to free warranty for problems
caused by installing or modifying other programs or changing or deleting diagnostic programs.
This product is a device to check the internal condition of the car through the car endoscope. The diagnosis and repair method
should be finally decided by the user. The manufacturer and the seller are not responsible for the result of the defect diagnosis
and repair method.
ⓒ All rights reserved, GIT Co., Ltd.
Limitation of Liability
Warning and cautions for safety before Use
Basic components
Ready to use the product
C1. Name of each part
C2. Product assembly
C3. Product charge
Device connection
D1. USB connection
D2. Wi-Fi connection
Screen layout
E1. Main screen
E2. Taken image
E3. Video recording
Function
F1. Note Mode
F2. Image editing
F3. Screen rotation
F4. LED brightness adjustment
Setting
G1. Resolution setting
G2. Sleep mode setting
Internal Battery Replacement
Product specification
Certification
J1. Certification
J2. Product warranty
4
5
6
7
8
9
11
12
13
13
14
15
15
15
16
16
17
18
18
19
Contents
Notice on patent, trademark, copyright, copyright and intellectual property rights in user manual
J
I
H
G
F
E
D
C
B
A
3

When connecting with a DC charger, do not use any charger other than the specified DC charger.
Make sure all cables are connected properly during operation. Do not disconnect the data cable or power cable
without completing the operation.
Please note that if the product is arbitrarily disassembled, modified or altered, normal service cannot be provided.
Use only genuine cables manufactured by GIT for cables, chargers, and all other parts and accessories used together.
Use the specified device and program.
Handle the product within the operating temperature and humidity.
Using this product in an excessively blocked space may cause radio interference. Wireless communication may be
interrupted temporarily or continuously, depending on the wireless communication environment.
This product is a short-range wireless device that can be limited in long-range connection.
[WARNING] The user is responsible for any damages incurred due to
insufficient knowledge of the contents of this endoscope user manual or
the operation used differently from the contents of this manual.
!
A. Warning and cautions for safety before use
[CAUTION] Inadequate handling can result in personal injury or property damage, with
more serious consequences under certain conditions. Follow all safety instructions and
instructions.
Do not store in locations where flammable materials and strong static electricity can be generated.
Chemicals or acids can corrode products and accessories.
Do not impact the product.
Cool the engine sufficiently(Less than 50 degrees) and use it at low temperatures.
Do not touch the camera while the LED is on. There is a risk of burns.
Be aware of the damage caused by high temperatures and moving parts when using the engine compartment.
Do not let the main unit containing the rechargeable battery and cable get wet.
Do not disassemble the rechargeable battery.
Be careful not to touch your eyes or skin with a leak caused by improper use of rechargeable batteries.
Only use the specified rechargeable batteries with the products.
Keep the camera and data cable out of contact with water.
Be careful to store all components when not in use.
Do not pull on the cable when moving or using the product.
GIT is not responsible for any damages caused by PCs that are not recommended to use with.
Do not expose the product to an X-ray or microwave; it may cause serious damage to the product.
Do not keep it in the following location:
- In places where the temperature and humidity are too high or too low (check the product specifications).
- Places exposed to direct sunlight for a long time
- Inside the vehicle in Summer season
- Place with moisture and watery
4

B. Basic components
Main body The main body connects the camera and the
flexible tube Perform the endoscope function.
0 degree camera used for frontal shooting.
90 degree camera used for side shooting.
The probe connects to the body and the camera.
It can be mounted in the camera lens groove to
lift a small bolt or screw.
It can be mounted in the camera lens groove to
lift a small bolt or screw.
The cable used to connect wireless
endoscopes and tablets by wire.
Cable length: 150cm
This manual contains information on how to
use the product safely and normally, and
related specifications. (Specifications may
change depending on the situation.)
C type gender that can replace 5Pin cable.
Cleaning fabric for wiping camera lenses.
A bag for carrying and storing the wireless
endoscope.
This cable is used to supply power to the
VCI using a DC power adapter.
Used to charge by connecting the DC cable.
Plug: Provides one of three types.
0˚ Camera
0˚ Magnetic holder
90˚ Magnetic holder
90˚ Camera
품 목 외 형 설 명
Flexible tube
Bag
Cleaning fabric
USB C-Type gender
Manual
DC cable
Micro USB cable
Charger & plug
GBS-101
MANUAL
5

Indicator LED
Connection method
Wi-Fi
USB
Charge
LED
Blinking blue
Blue/green flashing
Blinking green
Green light
Red/blue flashing
Blinking red
Red light
Red off
Blue light
Status
At boot
When booting up /
Waiting for Wi-Fi connection
Connecting to Wi-Fi
Upon Wi-Fi connection
Low battery
At power off
Charging
Fully charged
When the program is connected
Wi-Fi mode power button
UP button: LED Brightness button (0~3step)
DOWN button: Preview Rotation Button(90degrees)
Capture button
Long press: Start / stop movie recording
Short press: Take a picture
+DC 5V Input terminal
USB Input terminal
C1. Name of each part
6

C2. Product assembly
Check the direction of
the arrow and groove
Insert the flexible tube into the body and screw it to fix it.
Make sure the groove or arrow is pointing up when inserting the tube.
Make sure the red circle is aligned when inserting the camera.
Insert the camera on the other side of the flexible tube and turn it to fix it.
Camera
1
2
7

This product requires charging because it consumes its own battery when wirelessly used. USB connection is available without
charging.
C3. Product charge
1Connect the DC cable to the 5V 2A charger.
Remove the waterproof cover on the back of the main unit and connect the DC cable
to the DC input terminal.
2
Power supply method
Wi-Fi mode: Battery and charger
USB mode: Tablet
(Charging time: about 3 hours)
※
DC cable
8

Connect the micro USB cable.
Connect the other end of the cable to your tablet.
D1. USB connection
Wi-Fi power must be off to enter USB mode.
If the Wi-Fi power is on, press the power button to turn it off.
1
2
3
Wi-Fi mode power LED
Wi-Fi mode power button
Micro USB cable
9

KA981121312449231
12/08/2019
상단에 USB 접속 중임을 표시하고 있습니다.
LED brightness
adjustment
Preview screen
rotation
Run the GDSM / KDS app on your tablet.
4
Automatically try to connect to USB.
5When USB is connected, it moves to the
shooting screen.
6
If the USB connection fails, reconnect
the USB cable.
8
Capture button
Long press: Start / stop video recording
Short press: Take a picture
Start shooting with the button.
7
The LED lights up blue( ).
USB connection status
10

The green( ) LED lights up.
Wi-Fi connection
D2. Wi-Fi connection
Stand by until the boot is complete.
2
Look for the four-digit code on the label
on the bottom of the device.
3Run the app, enter the 4 digit code and
press the device search button.
4
Wi-Fi mode power LED
SSID: Borescope_XXXX
CODE: XXXX
Wi-Fi mode power button
Press the button for 3 seconds.
1
If you check Auto setup after remembering your password,
the code is saved to simplify the connection process.
When booting is complete, the LED blinks blue
and green( ).
Once the device is detected, press the
Connect button to connect.
5
It shows that you are connected to Wi-Fi at the top.
(Displays battery information and SSID of the device
together.)
6hen the Wi-Fi is connected, it moves to
the shooting screen.
KA981121312449231
12/08/2019
11
Indice
Altri manuali GIT Apparecchiature diagnostiche