Graco ProCart 233449 Manuale operativo

309244
Rev. D
First choice when
quality counts.
TI0822
INSTRUCTIONS–PARTS LIST
INSTRUCTIONS
This manual contains important
warnings and information.
READ AND KEEP FOR REFERENCE.
HVLP Compressor/Carts
240V AC, 50/60 Hz
ProCart Model 233449, Series A
45 psi (3.1 bar, 310 kPa) Maximum Working Pressure
Cart with 21/2-gallon pressure pot,
material hose, and compressor air hose
ProCart Model 233452, Series A
15 psi (1.0 bar, 104 kPa) Maximum Working Pressure
Cart with 21/2-gallon pressure pot,
material hose, compressor air hose
Related Manuals
HVLP Turbine Sprayers 309243. . . . . . . . . . . . . . . . . . .
HVLP Turbine Gun 309205. . . . . . . . . . . . . . . . . . . . . . .
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
COPYRIGHT 2001, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001

2 309244
Table of Contents
Warnings 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component Identification 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General Information 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setup 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagram 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graco Phone Number 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

309244 3
Notes

4 309244
Warnings
Know all hazards before operating sprayer!
Equipment Misuse Hazard: Equipment misuse
can cause the equipment to rupture or malfunction
and result in serious injury.
Before operating equipment, read all instruction
manuals, tags, and labels.
Check equipment daily. Repair or replace worn
or damaged parts immediately.
Do not exceed maximum working pressure (WPM) of the lowest–rated
system component: 45 psi (3.1 bar, 310 kPa).
Use fluids and solvents that are compatible with the equipment wetted
parts. See Specifications on page 24 for this information.
Wear hearing protection when operating this equipment.
Do not “blow back” fluid; this is not an air spray system
Follow Pressure Relief before cleaning, checking or servicing the
equipment.
TOXIC FLUID HAZARD: Hazardous fluid or toxic
fumes can cause serious injury or death if splashed
in eyes eyes or on skin, inhaled, or swallowed.
Know specific hazards of fluid you are
using and take protective measures as
recommended by the fluid and solvent
manufacturer.
Fire and explosion hazard: Solvent and paint
fumes can ignite or explode.
Sprayers generate sparks. Keep sprayer at least
20 feet (6 m) from explosive vapors.
Use in an extremely well ventilated area.
Eliminate all ignition sources; such as pilot lights,
cigarettes and static arcs from plastic drop cloths.
Do not plug or unplug power cords or turn lights
on or off in spray area.
Ground Sprayer, object being sprayed, paint and
solvent pails.
Do not use 1,1,1-trichloroethane, methylene chlo-
ride, other halogenated hydrocarbon solvents or
fluids containing such solvents in pressurized alu-
minum equipment. Such use could result in a
chemical reaction, with the possibility of explosion.

309244 5
Component Identification
Handle/Hose holder
Air Outlet/Check Valve
Remote pressure pot Remote pressure pot holder Material hose
Turbine latch
Power switch
Filter

6 309244
General Information
You will need:
Cleaning fluids: a compatible solvent; water–based paint also requires soap and water.
Suggested proper clothing:
•Safety glasses •Sturdy boots or shoes
•Respirator •Gloves
Power Requirements:
•240V AC 50/60 Hz, 8A circuit with a grounded outlet
(models 233430, 233431 and 233433)
•Extension cord must be 3–wire, 1.5 mm2. no longer than 15 m.
NOTE: Maximum extension cord length used with model 233452 is 15 m.

309244 7
General Information
PRESSURE RELIEF –Follow this procedure when cleaning, repairing or shuting down sprayer
Turn off turbine. Unlatch cup
GROUNDING –Improper installation or alteration of grounding plug will increase risk of electrical shock,
fire or explosion.
8069A
02882A
1. Turn off air supply to the pot.
2. Open pressure relief (A) on
pot until pressure is completely
relieved. Close relief.
For Pressure Feed Guns
For Cup Guns
AA

8 309244
Setup
1. Place remote pressure pot in pressure pot
holder on cart.
2. Follow Connect Fluid and
Air Supply instructions. Page 10.
pressure pot
turbine sprayer
(manual 309243)
Remote 21/2-gallon pressure pot
7933A
Turbine Sprayer
1. Place turbine sprayer on cart.
2. Move latch on cart to right to lock turbine sprayer.
3. Plug compressor/cart power cord into auxiliary
electrical outlet on turbine sprayer or into a separate
grounded electrical outlet.
4. Plug turbine sprayer into grounded electrical outlet.
Power Requirements. Page 6.
7932A
turbine sprayer
latch
auxiliary electrical outlet
Model 233449 shown

309244 9
Setup
7931A
Storage Position for Cart Handle
1. Turn knob to free handle.
2. Fold handle down to store.
knob

10 309244
Setup
Connect Fluid and Air Supply
The HVLP compressor/cart provides the air supply
for remote pressure pots.
The circled letters (page 11) indicate hose line
connections.
1. Connect gun air supply hose (A) between turbine
air outlet (B) and gun air inlet (C). DO NOT use
wrench to tighten connections; hand tighten only.
NOTE: The 4900 turbine uses a quick connector
at the air outlet (B). A wrench is not required to
connect air hose (A).
2. If using spray gun cup (D):
Connect cup to gun fluid inlet (E).
If using accessory remote pressure pot (F):
Connect fluid supply hose (G) between remote
pressure pot fluid outlet (H) and gun fluid inlet (E).
Connect pressure pot air hose (J) between pres-
sure pot air regulator inlet (K) and cart compressor
air outlet (L).
Connect to Electric Supply
Turbine Sprayer. Page 8.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Graco compressore d'aria