Greenleaf 250 Manuale utente

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
!
Greenleaf!250!Shower!Waste!
Pump!Instruction!Manual!
!
!
!
!!
!
Website:!!!!!www.!greenleaftrade.co.nz!
Contact:!!!!!![email protected]!

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
!
!"##$%#&'()*+(,-./#"(0&12#(3456((
!"#7(0&2#"(0&12#(3456(
!
8$2".94:2;.$(
The!Greenleaf!250!shower!waste!pump!comprises!the!tank!housing,!the!motor!
and!pump!assembly.!The!pump!is!only!suitable!for!use!in!domestic!wastewater!
installations.!
The!unit!activates!and!deactivates!automatically!depending!on!fluid!levels!in!the!
unit.!
!
<."5&%(=6#"&2;.$(
To!ensure!continued!reliability!of!the!pump!unit,!only!wastewater!from!showers!
and!hand!basins!should!be!connected!to!this!pump.!
!Do#not#connect#toilets#or#waste#disposal#units#to#this#pump.##
No!other!liquids!or!solids!should!be!allowed!to!enter!the!pump!as!they!can!cause!
items!the!pump!to!clog,!malfunction!or!to!burnout!the!motor.!!
The!maximum!temperature!of!the!fluid!entering!the!pump!must!not!exceed!50*c!
in!normal!permanent!operation.!
The!pump!5412($.2(>#(41#9!for!flammable!liquids,!gas!emitting!liquids,!
explosive!liquids,!fuel,!cleaning!agents!or!any!other!chemical!products.!
#
=6#"&2;$?(3";$:;6&%(
The!unit!comprises!a!tank!that!holds!the!wastewater!and!an!electric!powered!
pump,!which!pumps!the!wastewater!away.!
The!unit!is!automatically!controlled!and!operated!via!a!pressure!switch!inside!
the!tank!unit!
The!pump!will!start!operating!when!wastewater!flows!into!the!storage!tank!from!
a!shower!or!basin!unit.!!
#
@#:-$;:&%(A&2&(
Power!Supply!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!230V!/!50!Hz!
Power!Consumption!!!!!!!!!!!!!!!!!!!!!!!!!!!250!watts!
Water!Temp!Range!!!!!!!!!!!!!!!!!!!!!!!!!!!!!Minimum!1*C!to!max!60*C!
Normal!Operating!Temperature!!!!!Max!50*C!
Max!Lift!Height!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!4!metres!
Horizontal!Distance!!!!!!!!!!!!!!!!!!!!!!!!!!!!Maximum!pump!distance!40m!
Waste!Water!Connection!!!!!!!!!!!!!!!!!!2!x!40!mil!
Waste!Discharge!Line!!!!!!!!!!!!!!!!!!!!!!!!1!x!23!/!28mil!adaptor!to!suit!
#
B#"2;:&%(%;'2(;$(C#2"#1(((((((((D.";E.$2&%(2"&$16."2(9;12&$:#(;$(5#2"#1!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!(
4.0!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!10!
3.0!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!20!
2.0!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!30!
1.0!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!40!
!
(

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
(
,&'#27((
The!unit!is!to!be!used!only!in!the!manner!described!in!this!instruction!sheet.!
This!unit!is!not!suitable!for!use!in!swimming!pools,!paddling!pools,!or!any!form!
of!standing!water.!!
The!unit!must!not!be!situated!where!it!is!exposed!to!direct!water!or!rain.!
The!operation!of!this!unit!in!any!situation!other!than!for!its!recommended!use!is!
prohibited.!
Children!should!be!supervised!to!ensure!they!do!not!interfere!with!this!unit.!
Carry!out!a!visual!inspection!of!the!unit!prior!to!use!and!on!a!regular!bases.!
Do!not!use!the!device!if!it!is!damaged!or!defective.!!
Do!not!override!the!unit.!
Prior!to!carrying!out!any!maintenance!on!the!unit!the!power!cord!must!be!
disconnected!from!the!mains!supply.!
If!the!power!cable!is!damaged!it!must!be!serviced!and!replaced!by!a!qualified!
electrician.!
The!power!requirements!for!this!unit!are!230V!50Hz.!The!supply!to!this!unit!
must!be!230V!50Hz.!
Never!lift!or!carry!the!unit!by!the!power!cable.!
Ensure!the!power!plug!is!connected!in!an!area!that!is!dry!and!in!a!flood!proof!
zone.!!
(
0&"$;$?(
Please!read!all!the!safety!guidelines!and!instructions.!
NonYcompliance!with!the!safety!rules!and!regulations!can!lead!to!electric!shock,!
fire!or!serious!injury.!
#
(
8$12&%%&2;.$(!#$#"&%(
The!user!is!responsible!for!ensuring!that!the!unit!is!installed!in!compliance!with!
any!regulations!that!may!pertain!to!the!use!of!this!device.!
The!user!/!installer!will!ensure!that!adequate!precautions!are!taken!in!regard!to!
protecting!the!area!from!flooding!/!overflow!by!way!of!an!alarm!system!or!
standby!pump.!The!user!/!installer!is!responsible!for!any!consequential!damage!
that!may!arise!from!installation!that!may!cause!flooding,!water!overflow!or!any!
other!such!event!that!may!occur!form!the!operation!of!this!unit.!
The!supplier!accepts!no!responsibility!for!any!damage!caused!by!nonYoperation!
of!the!unit!at!any!time.!It!is!the!user!/!installer’s!responsibility!to!ensure!that!
back!up!devices!and!alarms!are!installed!to!protect!their!property!at!all!times.!
!
A"7(F4$$;$?(
The!unit!must!not!be!allowed!to!run!dry!at!any!time.!The!manufacturers!
warranty!is!invalid!if!it!is!determined!that!the!unit!has!been!run!dry.!
!
!
!
!
!

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
!
!
!
8$12&%%&2;.$(!4;9#('."(!"##$%#&'()*+(,-./#"(0&12#(3456(
When!installing!this!unit!please!ensure!that!the!vertical!lift!of!the!discharge!line!
precedes!any!horizontal!lift!in!the!discharge!line!and!should!be!as!close!as!
possible!to!the!outlet!elbow!on!the!unit.!
Once!you!have!started!the!horizontal!run!of!the!discharge!line!you!should!not!
add!any!further!vertical!lift!into!the!discharge!line.!
Note:!each!bend!or!change!of!direction!in!the!discharge!line!will!cause!minor!
losses!from!the!published!discharge!figures!for!this!unit.!
!
!
!
<.$GF#24"$(B&%H#(
Where!possible,!the!nonYreturn!valve!on!the!discharge!line!should!be!installed!
vertically.!If!the!nonYreturn!valve!is!installed!in!a!horizontal!position!ensure!that!
the!arrow!on!the!valve!is!at!the!top.!This!will!allow!the!nonYreturn!flapper!to!
hang!vertical!and!operate!in!a!correct!manner.!
The!nonYreturn!valve!has!a!sealed!fit!into!the!outlet!connection!of!the!unit!and!is!
secured!by!a!steel!clamp.!
The!nonYreturn!valve!has!a!flexible!connector!on!the!discharge!end!to!allow!
either!a!23!mil!or!28!mil!pipe!to!be!connected.!Steel!clamps!are!supplied!with!the!
unit!to!connect!the!valve!to!the!discharge!line.!
!
!
0&12#(0&2#"(8$642(I.$$#:2;.$1(
The!unit!has!two!40!mil!wastewater!input!connections!on!either!side!of!the!tank!
to!allow!a!shower!connection!from!either!the!left!or!right!side.!A!blanking!plug!is!
supplied!to!seal!the!side!that!is!not!in!use.!!
These!two!40!mil!inlet!connections!are!at!32!mil!centres!from!floor!level.!
!
(
3./#"(I.$$#:2;.$(
This!unit!is!220!Y!240!V/!50!Hz!and!power!consumption!is!250!watts.!The!unit!
can!be!connected!to!a!standard!power!outlet.!!
!
(
!
!
!
!
#
!
!
!
(
(

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
(
(
(
(
(
(
(
(
300mm
290mm
160mm
10mm
80mm
150mm
170mm
160mm
32mm
40mm Inlet
80mm
160mm
80mm
10mm
40mm Inlet
25mm Outlet
40mm
32mm
Power Lead
Greenleaf 250 Shower Waste Pump

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
(
(
((
(
(
(
(
(
(
(

!
www.greenleaftrade.co.nz!!!!!!!!!!!!!!!!!!!!!greenleaftraders@gmail.com!
(
(
(
@".4>%#(,-..2;$?(!4;9#(
(
(
!
PROBLEM!
CAUSE!
SOLUTION!
Motor!runs!but!pump!does!not!
drain!water!
Clogged!discharge!pipe!or!
outlet!valve!
Outlet!valve!is!half!closed!
Clean!discharge!line!and!outlet!
valve.!
Check!outlet!valve!
Pump!does!not!start,!water!
does!not!drain!
No!power!to!pump.!
Thermal!limit!switch!has!
tripped!
Check!power!source!
Wait!for!thermal!limit!switch!
to!reset,!approx.!20!mins!
Motor!hums!but!does!not!run!
Solid!object!stuck!in!pump!
Starting!condenser!defective!
Check!for!object!
Replace!condenser!
Water!drains!but!pump!
continues!to!run!and!cuts!out!
on!thermal!switch!
Foreign!object!lodged!under!
pressure!switch!
Faulty!pressure!switch!
Clear!object!from!pressure!
switch!
Replace!pressure!switch!
After!draining!pump!
continues!to!cycle!several!
times!
Water!flowing!back!in!to!
pump,!back!flow!valve!
installed!incorrectly!or!
defective!
Check!back!flow!valve!for!
installation.!Clean!valve!as!
necessary!
Motor!is!noisy!when!running!
Check!for!foreign!object!in!
pump!
Remove!foreign!object!from!
pump!!
Water!flows!back!to!shower!
Insufficient!fall!in!line!
!
Inlet!valve!defective!
Shower!needs!to!be!raised!or!
pump!lowered.!
Clean!inlet!valve!
!
Indice
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente