H-L Data Storage HLT-SDBF1 Manuale utente

Confidential
MODEL : HLT-SDBF1
Customer P/N :
Thermal Sensing Board
SPECIFICATIONS
Development Department
APPROVED
2021.09.27

MODEL : HLT-SDBF1
Customer P/N :
TO :
APPLICATION
Traced by Checked by Approved by
APPLICANT
Confidential
IT.KIM
NH.KWAK
SH.BAE
KW.KIM
SS.KIM
JH. OH
BG.Ahn SP. KONG

HLT-SDBF1
Confidential
Revision
No. Date
of Rev. Contents of Revision Changed
page
0.1 2021.06.18 Initial Update
0.2 2021.06.24 Modify STANDARD PERFORMANCE 5
0.3 2021.09.24 Modify GENERAL SPECIFICATIONS
Modify RELIABILITY 3
6
0.4 2021.09.27 Modify STANDARD PERFORMANCE (Add
Software)
Modify RELIABILITY
5 ~ 8
9
Revision History

HLT-SDBF1
Confidential
1. SCOPE OF DOCUMENT
2. GENERAL SPECIFICATIONS
3. STANDARD CONDITION OF EVALUATION
4. STANDARD PERFORMANCE
5. RELIABILITY
6. LIFE TEST
7. PACKING SPECIFICATION
8. HANDLING
9. ATTACHMENT
Fig. 1 APPEARANCE DIAGRAM
CONTENTS
-1 -

HLT-SDBF1
Confidential
■This document describes the specification of Thermal Sensing Board
“HLT-SDBF1”.
■The provisions of this document maybe altered upon agreement between
both parties.
■If any disagreement should arise, these two parties shall meet in good
faith to resolve the problem.
■Within the range of these specifications, parts are subject to change
without notice for technical improvement.
■Please be sure to observe the following each time you deliver your
finished and/or semi-finished products containing the device(s).
Otherwise, HLDS may not be able to assume the responsibility for things to
happen.
• Always use the device(s) within conditions given in the specifications.
• Never given additional process to the device(s).
• Before use, be sure to read this instruction manual and use the product
safely and correctly.
• The illustrations in the user manual may differ from the actual product,
and the contents may be partially changed without notice to the user for
performance improvement.
• To use the product in connection with another device, first check that the
device is compatible with the product.
1. SCOPE OF DOCUMENT
-2 -

HLT-SDBF1
Confidential
Items Specifications
Display 29 Inch / 1920 x 540 (Support Touch Display)
CPU RK3288 (4 x A17)
RAM / eMMC 1GB / 8GB
RGB Camera HD (1280x720), SD(640 x480)
Thermal Sensor Heimann 32x32, HTPA32x32dR2L5.0/0.85F7.7eHiC
LED Lighting O
Speaker O
Wi-Fi / BT Wi-Fi 2.4G / BT 4.2(Profile : A2DP, HID)
Ethernet 10M/100M Adaptive Ethernet
USB Type-A 1ea, OTG 1ea / Format : FAT32, NTFS
Other I/O Relay
Power DC 12V / 4A (Power consumption 35W - Typical)
Dimensions 226 x 775 x 42mm (W x H x D)
Mass About 4.0 Kg
Operating temperature
and humidity 5℃to +35℃, below 65%RH (without dew, frost)
(Recommendation 25℃)
Storage temperature
and humidity (Transportation) -20℃to +60℃, below 90%RH (without dew, frost)
Appearance Fig.1
Operating System Android 7.1.2
Detection distance
(Face/Thermal/Mask) 0.3m ~ 0.8m (Recommendation : 0.5m)
Detection time
(Face/Thermal/Mask each.) Under 5sec
Thermal detection range 32 ~ 42℃(±0.3℃)
Thermal detection accuracy ≤±0.3˚C at 0.5m about 25˚C ambient temperature
Thermal detection precision ≤±0.3˚C at 0.5m about 25˚C ambient temperature
Face recognition probability ≥ 90% without mask (tentative)
Mask detection probability ≥ 95% (tentative)
Face registration count About 1.000 people
QR code read O
Support movie format Webm (VP9)
Languages Korean/Japanese/English
-3 -
2. GENERAL SPECIFICATIONS
*¹The detection distance or face recognition speed may vary depending on the usage
environment.

HLT-SDBF1
Confidential
-4 -
Note.
(1) The detection distance or face recognition speed may vary depending on
the usage environment.
3. STANDARD CONDITIONS OF EVALUATION
(1) Environment Temperature 25℃±2 ℃
Humidity 60%±5%[RH]
We can adopt temperature range 15 ℃~35 ℃,humidity range
45%~65%[RH] If it occurs no doubt about judgment.
(2) Environment of Operating Condition
5℃to +35℃, below 65%RH (without dew, frost)
(3) Evaluation
Use HLDS standard measuring equipment.

HLT-SDBF1
Confidential
-5 -
4. STANDARD PERFORMANCE
Detection Quality Validation Metrics
Item Spec. Remark
Detection distance
(Face/Thermal/Mask) 0.3m ~ 0.8m (Recommendation : 0.5m)
Thermal detection range 32 ~ 42℃(±0.3℃)
Face registration number About 1,000 people
Detection time
(Face/Thermal/Mask each.) Under 5sec
※For Mask & Thermal detection metric test methodology, refer to “HLDS SAFE PASS
PLUS User Manual".

HLT-SDBF1
Confidential
-6 -
4. STANDARD PERFORMANCE
Software Function Validation Metrics
Item Spec. Remark
Normal Performance Test
1. Change password
2. Log-In
3. Device setting
4. Device operating
5. Face recognition
6. ChangeAccount
On/Off by function, change of setting
value and confirmation of operation
※Environment Temperature 25℃±2 ℃
Humidity 60% ± 5 %[RH]
Temperature measurement
Repeat measurement during 2 hours (5
times / sets) every 30 minutes using
blackbody. (Under ±0.3℃)
※Environment Temperature 25℃±2 ℃
Humidity 60% ± 5 %[RH]
※Distance between TSB1 & blackbody
is 50cm.
Face registration
1. With Mask : Up to 80%
2. Without Mask : Up to 90%
※Environment Temperature 25℃±2 ℃
Humidity 60% ± 5 %[RH]
※When the face is aligned with the
indicator line.
QR Code
1. QR code + Face recognition
2. Check QR code only
: Save QR code only KR COVID QR
(Naver, Kakao, PASS)
※Environment Temperature 25℃±2 ℃
Humidity 60% ± 5 %[RH]
※When the QR is aligned with the
indicator line. (Check QR code only case)
※For Mask & Thermal detection metric test methodology, refer to “HLDS SAFE PASS
PLUS User Manual ".

HLT-SDBF1
Confidential
-7 -
4. STANDARD PERFORMANCE
Software Function Validation Metrics
Item Spec. Remark
Mask detection
Up to 95%
※Environment Temperature 25℃±2 ℃
Humidity 60% ± 5 %[RH]
※When the face is aligned with the
indicator line.
Information Display
1. Video play
- Format : WEBM(VP9)
- File size : Maximum 150MB
- Resolution : 540 x 1586 (pixel)
※Interruption may occur depending
on the state of the file.
2. Image display
- Format : JPG, PNG
- File size : Maximum 10MB
- Resolution : 540 x 1586 (pixel)
※Environment Temperature 5℃to
+35℃, below 65%RH (without dew, frost)
※For Mask & Thermal detection metric test methodology, refer to “HLDS SAFE PASS
PLUS User Manual ".
Indice