Habitat HTE-01 Istruzioni operative

Programming Guide
Smarter Control Solutions.

About This Manual
This manual uses special attention icons to alert the reader of important
safety concerns, information important to reliable operation of the controls
or helpful installation/setup information.
Safety: Indicates a condition which may cause severe personal
injury, death or major property damage.
Important Information: Indicates information which requires
special attention for correct operation of the control.
Your Benet: Indicates helpful installation or setup information.
For installation and instructions, refer to the
Installation & Pairing Manual.
For operating instructions, refer to the
Operation Manual.
Documentation
i

ii
Habitat Technologies
330 East 38th Street, Suite 530
New York, NY 10016
Customer Service
Toll Free: 1-800-717-1682
Web Site: www.habitattechnologies.com
Manual Table of Contents
About This Manual
HTE-01 Thermostat - Home Screen Display
HTE-01 Thermostat - Controls
HTM-01 Base Module - LED Status Indication
HTE-01 Thermostat - Parameter Setup
- Identify HTM-01 Base Module(s)
- Pairing Additional HTM-01 Base Module(s)
- Daylight Savings Time, Date & Time Settings
- Emergency Heat Setting
- HTE-01 Thermostat Schedule Setup
HTE-01 Thermostat Administrative Parameters
- Unpair Modules
- Enable Auto Changeover, Button Press Sound, Enable Compressor
O Delay
- Compressor O Delay Time, Heat/Cool Dierential, Span
- Temperature Oset, Freeze Protection
- Maximum/Minimum Set Point, Lock Set Point
- Base Module Alarm Check Period, Factory Reset
Designed and Engineered in New York
U.S. registered Trademark, Patents pending
Copyright 2020, All Rights Reserved.
Thermostat
HTE-01
Module
HTM-01
i
1-2
3-4
5
6
7-8
9-10
11
12
12-14
15
15
16
17
18
19
20

1
Home Screen Display
1
2
3
4
5
6
7
9
10
11
12
13
14
8

2
1
Pairing status indicator:
Connected
Not connected
8Time display1
2
WIFI status indicator (only shown
when WIFI module is used)
Connected
Not Connected
9
Override status indicator1:
Override – Temporary Override
Perm. Override – Permanent
Override
3
Thermostat Battery power indicator
status, only shown when on battery
power used.
Full Half Low Replace
10
Schedule running indicator:
Schedule – Schedule running1
(Blank) No Schedule
4System type 11 Set point
5Room temperature 12 Celsius or Fahrenheit units
6Mode status 13 Emergency heat indication
7Additional system type text 14 Fan speed indication
1 - Schedule must be activated for the time & schedule status to be displayed.
See the Habitat programming guide for information on setting up a schedule.

3
HTE-01 Thermostat Controls
1
2
3
4
5
Front
View
Bottom
Side View

4
LCD Display – See preceding pages for detailed descriptions of the
display icons.
– Increase or Decrease the target temperature set point.
Changing the target set point:
• Press the or button while in Auto, Heat or Cool Modes.
• If a schedule is programmed, “Override” is displayed below the
time indicating that the current target setpoint will be maintained
until the:
- Next schedule period
- Set point is changed to the scheduled value
- Mode button is held for 3 seconds, displaying “Schedule”,
“Perm. Override”
- To change the temperature units between °F and °C, simultaneously
press the and buttons briey.
Mode – Cycle through Operation modes:
Fan – Cycle through desired Fan Speeds.
Manual Reset – Reboots the thermostat system only.
To save energy, the display will turn o after a period of inactivity.
Before making changes, press any button to activate the display,
illuminating the screen.
5
1
2
3
4

5
The following table shows the base module state corresponding to the
LED Status Indication.
HTM-01 Base Module LED Status Indication
LED Status Indication State Description
Flashing
Green Pairing Base module is seeking to pair with
the thermostat.
Green Paired Base module is paired with the thermostat.
Red Not
Paired
Base module is not paired with a
thermostat.
2 Red
Flashes then
Pause
Alarm
Base module indicating an alarm (Water
Leak, Smoke or CO2) accompanied by
descriptive text on the thermostat display.
Flashing
Red
Identify
Mode
Base module is in identify mode initiated by
the thermostat or web application.
Alternating
Green/Red
Factory
Reset
Hold the PAIR button for 10 seconds and
it begins to ash. Release and press again
briey to reset.
x y
Flashing
xtimes
Green then
ytimes Red
Firmware
Version
Indicates version x.y (eg. 2 green then 7
green = version 2.7.) Press and release PAIR
button within 10 seconds of power up.
nFlash Red
ntimes
Base
Module
Number
Indicates base module number (1-8). Press
and release PAIR button more than 10 sec-
onds after power up.
2

6
Parameter Description Key Action
Base Module Identify or Pair
base modules
Identify existing base module(s)
Pair additional base module(s)
Daylight Savings
Time (DST) Enable/Disable DST
or
Toggle Daylight Savings Time
Mode ON/OFF
Month Set Month Set Month – 1 to 12
Date Set Date Set Date – 1 to 31
Year Set Year Set Year
Hour Set Hour Set Hour – 12 am to 12 pm
Minute Set Minute Set Minute – 1 to 59
Emergency Heat Enable/Disable Toggle Emergency Heat “y” or “n”
Schedule Enable/Disable
Schedule Toggle Schedule “y” or “n”
To access Parameters, press & hold “Mode”
& “Fan” until a sound is played (3 seconds),
then release. Use the “Fan” button to scroll
forward and the “Mode” button to scroll
backward through the available parameters.
Parameter Setup

7
Access parameters
using the procedure
described earlier.
Press to
identify base mod-
ules. “All” ashes
indicating all mod-
ules. Press
to scroll through the
list of connected
base modules.
If any module has
been paired but has
lost its link to the
Thermostat, the pair-
ing status indicator
will blink along with
the number of the
module that has lost
its link.
Identify HTM-01 Base Module(s):
Altri manuali per HTE-01
4
Questo manuale è adatto per i seguenti modelli
1
Indice