hadewe Argos2 Manuale utente

art. 0572
FB 04-278 Rev. 2
Date: 07.02.2019
Manual
Argos2

2
Contents
Foreword 3
Safety Instructions 4
Cleaning & Disinfection 10
Getting to Know the Unit 11
Before Use 12
Area of Application 12
Operation 12
Application 14
Operation Steps 14
Work Positioning 15
Fill Spray Liquid Tank 17
Filter Change 17
Insert Bur 18
Spray Function 18
Drying Function/Tool Change 18
Suction 18
Adjusting the Speed 19
Foot Switch 19
Maintenance & Care 20
Washer 20
Spray Liquid Filter 20
Chuck Cleaning 21
Cleaning Function 22
Maintenance Overview 22
Handling Instructions 23
Troubleshooting 24
Technical Data 26

3
Safety Instructions
The Argos2foot care unit was produced according to strict quality criteria and
uses the latest technology in its design. The images in this manual may vary
slightly from the product you have bought as we are constantly developing our
products.
This user manual includes a detailed description and explanation of how to
use the Argos2unit. If you have any questions or suggestions, you can contact
us by telephone or email.
This user manual belongs with the Argos2unit. Keep it somewhere safe. If you
give this product to someone else, please include this document as it includes
important information on how to correctly use the product.
Short description of functions
The Argos2is a device for the treatment of callus and nails. The handpiece is
compatible with rotating tools such as diamond polishers, steel cutters and
ceramic cutters. These can reach at speeds up to 40,000 rpm and therefore
provide an efficient way of removing tissue. The direction of rotation can be
changed by pressing a button. The integrated spray function emerges reliably
bundles emerging dusts and the integrated filtered suction function effectively
sucks up any dust particles. The speed of the bur, the amount of spray and the
suction function can be adjusted via knob.

4
Safety Instructions
The installation of the working area has to cor-
respond to the relevant regulations. Set up the
unit in such a way, that the louvers are not covered
and the extracted air can escape well.
To avoid the risk of an electric shock, this de-
vice might only be connected to a power sup-
ply with protective conductor.
If you pull the power plug, it will stop the con-
nection to the mains power supply. Set up the
unit so that the power plug is always accessible.
The power switch should also always be easily ac-
cessible.
Only switch on the unit if the handpiece rests
secured in the handpiece holder, or if you hold
it safely in your hand.
Prevent the permeation of liquids into the con-
trol unit. The electronic elements could be
damaged. Clean the outside of the box only with a
damped cloth. Be sure you unplug the unit before.
Only use distilled water plus a sterilizing addi-
tive (e.g. hadewe AquaHy, art. 8555). If you
use other brands, pay attention to their manuals if
you can use them for this purpose. Never use tap
water. In case you are working with an alcoholic fluid

5
Safety Instructions
or other burnable liquids, there is always the danger
of fire or explosion hazards. Never refill the tank di-
rectly over the unit to avoid in case you accidently
spill water, this will flow into the unit.
If spray liquid enters the suction hose, dry the
handpiece so that the suction hose is at the
bottom. Pull the suction hose off the control unit.
Now place the handpiece below the control unit so
that the liquid can drain away without getting into the
handpiece. If necessary, replace a wet dust filter.
The unit must be used again only when the liq-
uid has completely evaporated. If the error occurs
repeatedly, the unit must not be operated and must
be repaired by a specialist.
Change the spray liquid every day. Always add
disinfection additive to the distilled water.
Make certain to observe the instructions of the man-
ufacturer. Rinse the tank daily and fill it with fresh
spray liquid every day.
Empty the unit if it is not in use for a longer pe-
riod of time (e.g. before vacations). Clean out
the tank. Set the spray function on maximum. Now
start the spray function, and the spray liquid will
spray for approx. 3 min. The fluid will be blown out
of the complete spray system and handpiece.

6
Safety Instructions
Only when pulling the mains cable, you can
ensure that the device will be completely dis-
connected from mains check the mains cable regu-
larly for damages, and in case of such let it change
or repair from an authorized service center.
Prevent your hair from wrapping itself around
moving parts. If applicable, wear a hair net.
This appliance can be used by children aged
from 8 years and above and persons with re-
duced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been
given supervision or instruction concerning use of
the appliance in a safe way and understand the
hazards involved. Children should be supervised not
to play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
When working with materials which might cre-
ate dust or moisture use a drilling unit with
suction or spray technique. Wear a nose and mouth
protection. Always follow the safety instructions pro-
vided by the manufacturer of the materials being
formed.
For safety reasons you must always wear dis-
posable gloves and protective glasses when

7
Safety Instructions
operating this unit. In addition, a face mask conform-
ing to EN 14683 type IIR or EN 149 FFP 2 must also
be worn.
When changing the filter it is advisable to wear
a face mask conforming to EN 14683 type IIR
or EN 149 FFP 2.
Ensure that the patient’s foot and the hand-
piece are held firmly in place during the opera-
tion. To prevent injury, work with extreme caution on
the foot of the patient, and use only light pressure.
To ensure that the bur/tool sits firmly in the
chuck, do not work with tools which:
•have an oily shaft
•are worn
•are bent.
Before using the equipment, assure that
•the tool can be pushed far enough into the
chuck (test this with a dipstick and clean if
necessary),
•the tool will not cant/jam while clamping it,
•the inserted tool sits properly in the chuck
•the tool is approved for using it at the max
speed (see manufacturer’s instructions), or

8
Safety Instructions
•only use the speed required by the instru-
ment,
•the tool is absolutely dry.
For safety reasons do not change the tool
while the motor is running.
Switch off the unit immediately if
•the bur comes off during the treatment itself.
•the motor blocks during the treatment.
Only use the suction function if you have in-
stalled the suction filter. Check this filter every
10 operating hours. If it is full, please exchange it. A
filter should be exchanged at least after 50 operat-
ing hours.
If spray liquid leaks from the unit, then a dis-
turbance is present. The unit has to be sepa-
rated from the socket and cannot be used any long-
er.
When the device is brought out of standby
mode it will run with the rotation speed and
suction power used last. Take care to not start the
mill at an overly high rotation speed. Select the re-

9
Safety Instructions
quired rotation speed before changing the milling
tool.
Never use the suction to vacuum any liquids or
air/liquid fog which contains particles of liquids.
Always follow the operating instructions. Do
not carry out any repairs, modifications or
maintenance work yourself. This is only to be ac-
complished by an authorized specialist. The mains
cable may also only be changed by the manufactur-
er or an authorized specialist. Maintenance records
may be supplied to repair workshops and trained
technicians upon request. Never remove the hous-
ing, while the equipment is plugged in as some
components are live. A spare parts list may be sup-
plied to qualified persons (repair workshops). No re-
sponsibility can be accepted for unauthorized or im-
proper tampering with the unit, which nullifies the
guarantee and any other liabilities.

10
Cleaning & Disinfection
The device is designed to be compatible with rotating in-
struments which do not penetrate the skin or mucosal or
inadvertently may still cause injuries. For this application please
adhere to the cleaning and disinfection instructions provided be-
low. After every treatment please carry out these steps:
•Remove the rotating tool (e.g. bur) first. To do so, pay atten-
tion to the instructions of its manufacturer.
•Remove clothing remains through wiping off easily the unit
with a moistened paper cloth. Afterwards clean all surfaces
with a disinfection cloth (e.g. Mikrozid AF cloths of Schülke
and Mayr).
Indice
Altri manuali hadewe Pedicure Spa

hadewe
hadewe Veloria Chrome Manuale utente

hadewe
hadewe Medeas Manuale utente

hadewe
hadewe HELIUS-40 Manuale utente

hadewe
hadewe Xantos-BT Manuale utente

hadewe
hadewe Azuras CHROME Manuale utente

hadewe
hadewe Helius 22 Manuale utente

hadewe
hadewe SB2 Series Manuale utente

hadewe
hadewe Veloria MD Manuale utente

hadewe
hadewe Auroria MD Manuale utente

hadewe
hadewe Veloria Manuale utente