1. Integral Installation
The installation of the collectors is integrated with that of the water storage tank
both are well incorporated with the building, which can save indoor space as far as possible.
and they
2. Selective Coating Absorber
The high-efficient flat collector absorber uses the state-of-the-art selective
coating, which features high absorptivity, low reflectivity, beautiful appearance and long
duration.
absorbing
3. Pressure-Bearing-Type System Water Heating Center
The pressure-bearing-type water heating system is multi-purposed with
water supply, which ensures strong and comfortable water flow with the easy
thermo-regulator. In addition, the water heater uses the enamel tank with good corrosion
resistance and long duration.
multi-channel
4. User-friendly Design
The system is furnished with the alternative electric heater, which can be used
and convenience to meet the need for hot water in various climates of different seasons.
with safety
1. The roof of the water tank and collectors shall be solid and firm enough to sustain
weight two times that of the tank filled with water. In the case of a non-load-bearing roof,
protective measures shall be taken such as installing additional mounts, using screws
penetrating the wall and installing rear panels. If the roof angle is above 20°, fixation
equipment shall be added to fasten the water tank, such as the steel wire rope.
the
2. Collectors shall be installed facing the south as far as possible.
completed and before the system is full of water, it is IMPORTANT to check the following:
depending upon the positioning of the frame on the roof and any minor fall the roof may
have, ensure the collector rail is either horizontal or is higher on the hot outlet side of the
solar collector(s).If in doubt use a spirit level.
Once the installation is
3. In the installation of the collector(s),
with a continuous fall of not less than 10° from the storage tank to the solar collector(s). If in
doubt use a spirit level, and counter-slope is prohibited.
The solar hot and solar cold pipes grade downwards
4. The power cable terminals shall be embedded in the indoor wall. The company
held liable for any accident caused by any cable terminal installed outdoors. The installation
technician shall explain to the user to that effect before installation.
shall not be
5. The pressure of inflow water may be above 0.85MPa so that a pressure limiting
be installed on the way of tap water to the heater.
valve shall
6. does not have freeze protection. The system is not suitable for in
stallation in areas subject to frost or freeze conditions. Freeze conditions occur below 6℃.
The system has NO WARRANTY for freeze damage.
The direct system
Installation Consideration
4