PHOENIXNRG STREAMLINER INSTALLATION GUIDE
9hanleyledsoluons.com | 800.542.9941
Cautions for installation and use:
• Disconnect the power before installaon to ensure safety.
• Disconnect or remove the exisng ballast before installaon to avoid short circuit.
• This product must be installed by a qualied electrician or electrical engineer.
• This product must be installed according to the requirements and instrucons in the specicaon sheet.
• A surge protector is recommended to be used with this product to prevent damage caused by power surges,
inrush current and other environmental causes of power spikes.
• This product is not intended for use with dimmers; not intended for emergency lighng.
• Suitable for dry and damp locaons; suitable for use in enclosed luminaries.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
CAUTIONS
TROUBLESHOOTING
Malfuncons Possible Causes Soluons
All LEDs do not work
No power from primary Double check primary connecons and turn power on
Poor contact between
socket and product
Remove and reinstall the product or adjust the lamp holders;
Replace damaged sockets
Driver inside the
product is damaged Replace damaged tube with new tube
Part of LEDs
do not work
No electricity to those
LEDs due to open circuit Maintain the circuit or replace with new tube
The diodes inside
the modules fail
Conrm voltage from primary is stable & safe;
replace with new tube.
Brightness of LEDs
is weak or uneven
LED diodes inside
modules malfuncon Replace with new modules or new product
Power input of
driver is insucient Replace with new product
LEDs are blinking
Driver inside the
product is damaged Replace with new product
Poor contact between
socket and product Adjust the contact between the tube and socket
WARNING – Risk of re or electric shock. LED Retrot Kit installaon requires knowledge of sign electrical systems. If not qualied, do not aempt
installaon. Contact a qualied electrician.
WARNING – Risk of re or electric shock. Install this kit only in host signs that have been idened in the installaon instrucons and where the input
rang of the retrot kit does not exceed the input rang of the sign
WARNING – Risk of re or electric shock. Installaon of this LED retrot kit may involve drilling or punching of holes into the structure of the sign.
Check for enclosed wiring and components to avoid damage to wiring and electrical parts.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installaon.
Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installaon.
Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7 mm (1/2 in.) diameter require a metal patch
secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-hardening caulk.