Haws 8320 Guida

01/20 Model 8320-8325/8320CRP Page 1 of 5
1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424
No. 0002080170 (22)
Model 8320-8325/8320CRP
Shower and Eye/Face Wash
INSTALLATION, OPERATION
&
MAINTENANCE INSTRUCTIONS
LIMITED WARRANTY
HAWS warrants that this specific product is guaranteed against defective material or poor
workmanship for a period of one year from date of shipment. HAWS liability under this
warranty shall be discharged by furnishing without charge F.O.B. HAWS Factory any
goods, or part thereof, which shall appear to the Company upon inspection to be of
defective material or not of first class workmanship, provided that claim is made in writing
to Haws within a reasonable period after receipt of the product. Where claims for defects
are made, the defective part or parts shall be delivered to the Company, prepaid, for
inspection. HAWS will not be liable for the cost of repairs, alterations or replacements, or
for any expense connected therewith made by the owner or his agents, except upon
written authority from HAWS, Sparks, Nevada. HAWS will not be liable for any damages
caused by defective materials or poor workmanship, except for replacements, as provided
above. Buyer agrees that Haws has made no other warranties either expressed or implied
in addition to those above stated, except that of title with respect to any of the products or
equipment sold hereunder and that HAWS shall not be liable for general, special, or
consequential damages claimed to arise under the contract of sale.
The emergency equipment manufactured by HAWS is warranted to function if installation
and maintenance instructions provided are adhered to. The units also must be used for the
purpose for which they were intended. This product is intended to supplement first-aid
treatment. Due to widely varying conditions, Haws cannot guarantee that the use of this
emergency equipment will prevent serious injury or the aggravation of existing or prior
injuries.
NO OTHER WARRANTIES EXPRESSED OR IMPLIED ARE AUTHORIZED, PROVIDED OR
GIVEN BY HAWS.
NOTE TO INSTALLER: Please leave this information with the Maintenance Department.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL, PLEASE CALL: 1-800-766-5612
FOR PARTS CALL: 1-888-640-4297

01/20 Model 8320-8325/8320CRP Page 2 of 5
LOCATION OF UNIT: The Model 8320/8320CRP/8325 Emergency Shower should
be installed in close proximity to potential accident areas. It should be clearly
identified, free from obstructions and easy to access.
SUPPLY LINE: The minimum recommended line size is 1-1/4” IPS with 30-90 psi
(2-6 ATM) flowing pressure. Where sediment or mineral content is a problem, an
inlet filter is recommended.
PLUMBING CONNECTIONS: Inlet supply is female 1-1/4” IPS. Waste outlet is
female
1-1/4” IPS.
INSTALLATION PROCEDURE
Refer to Installation Drawing for clarification. Use pipe joint sealant PST #565 (Loctite)
on all connections.
STEP 1: Prepare the emergency shower foundation by using the floor flange
assembly as a template.
STEP 2: Once the foundation is ready, fasten the floor flange to the foundation.
Use minimum 3/8” fasteners (not supplied).
STEP 3: Assemble lower tee (1-1/4”) to the floor flange.
STEP 4: Attach nipple (1-1/4” x 21-1/2”) and eyewash loop assembly to lower tee
and tighten, grabbing the waste bend of loop assembly for leverage.
STEP 5: Attach nipple (1-1/4” x 24”) and tee (1-1/4”) to loop assembly and tighten.
STEP 6: Attach nipple (1-1/4” x 24”) and tee (1-1/4” x 1-1/4” x 1”) and tighten.
STEP 7: Attach valve assembly with nipple (1” x 9”) to tee and tighten with a spud
wrench.
STEP 8: Assemble the street elbow (1”) onto nipple (1” x 12-1/2”).
Attach nipple onto valve.
STEP 9: Attach showerhead onto street elbow (1”).
STEP 10: Assemble the sign onto the unit. Use the strap, screws, washers and nuts
provided to mount the sign onto the upright. The sign should be positioned
for maximum visibility.
STEP 11: Insert the plug into the optional supply line tee that is not used. Before
connecting the supply water line to the emergency shower, FLUSH THE
LINE THOROUGHLY.

01/20 Model 8320-8325/8320CRP Page 3 of 5
TROUBLESHOOTING
PROBLEM REPAIR CHECKLIST
1. No flow. 1. Check the main shut-off valve.
2. Insufficient water flow. 2. Verify minimum 30 psi (2 ATM) flowing
supply line pressure.
3. Insufficient water flow on
eyewash, however, shower is
sufficient.
3. a. Verify minimum 30 psi (2 ATM) flowing
supply line pressure.
b. Probable clogging of flow control due to
inadequate line flushing. Unscrew
eye/face wash head and remove the
four screws to disassemble the head.
Clean flow control and reassemble
head. See SP65 Installation Drawing for
details.
c. Remove cap located on L – Strainer
using a 3/8” allen wrench to access and
clean filter screen.
4. Eyewash or face wash
streams do not meet desired
eye level or are not balanced.
4. Possible blocked flow control see above
solution. (Possible non-leveled eyewash
assembly.)
5. Insufficient water flow at the
showerhead, however,
eyewash is sufficient.
5. Probable clogging of flow control inside
shower head. Unscrew shower head off
of elbow and clean rubber flow control.
6. Water does not drain properly. 6. Check your drain system for debris.
Check the main waste line of your
building to see if it does handle the
capacity required for the entire drainage
system.
7. Water leak between joints or
fittings. 7. Tighten loose connections. If leak
persists, the application of hot water will
sometimes reseat improperly applied
joint compound. After 30 minutes wait
and retest. A persistent leak will
necessitate reassembly and additional
sealant.
For more information on Haws Products, please see our website: www.hawsco.com
© 2020 Haws®Corporation – All Rights Reserved
HAWS® and other trademarks usedin these materials are the exclusive property of Haws Corporation.

1 EYE/FACE WASH ASSY
PARTS BREAKDOWN
11
2
3BOWL
4VALVE ASSEMBLY
5SHOWER HEAD
6SHOWER VALVE ASSY
7SHOWER SIGN
8FLOOR FLANGE
9PULL ROD
10 STRIPE TAPE
11 TEST TAG
12 BOWL HOLDER
L-STRAINER
9
5
6
7
10
3
2
12
4
8
13 STRAINER REPAIR KIT
SP65 EYE/FACE WASH ASSEMBLY
1
APPROVED
DRAWN
PART NUMBER
DRAWING NO.
SCALE: SHEET OF
REV
DRAWING TYPE: SIZE: A
BYECN NO.
PAGE
DATE
DATE
ECN:
REVISED PER
CHKD
Haws Corporation - All Rights Reserved
HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
ITEM DESCRIPTION
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
WHEN ORDERING PARTS PLEASE SPECIFY MODEL NUMBER.
PART NO.
CLF
03/12/93
A22
0002080170
8320-8325/8320CRP
1:1
11
NE
01/14/20
DP
4 of 5
PARTS BREAKDOWN
5497
2020
13
SP65
SP509
SP93
SP225
SP829
SP260
SP178
SP75
SP200
SP185
SP170
0003049570
VRKEWSTR

TOP VIEW
FLOOR LINE WASTE
1-1/4"
IPS
SUPPLY
1-1/4"
IPS
3
25"
635mm
MIN 83" (2083mm)
MAX 96" (2438mm)
SP829
653
8"
1661mm
111
4"
286mm
MOUNTING DETAIL
30°
3/8"
9.5mm
8"
203mm
ØB.C.
9"
229mm
Ø
3X Ø
9 3
8"
235mm
413
4"
1061mm 6 5
8"
167mm
89 1
4"
2266mm
271
2"
699mm
62"
1575mm
33"- 53"
838mm-1346mm
FLOW PATTERN
APPROVED:
DRAWN:
PART NUMBER
SCALE: SHEET OF
REVISION
DRAWING TYPE: SIZE: A
BY:ECN NO.
PAGE
DATE:
DATE:
ECN:
REVISED PER
CHK'D.:
Haws Corporation - All Rights Reserved. HAWS and other trademarks used in these materials are the exclusive property of Haws Corporation.
CR
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS
MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
SLS
5/1/08
22
0002080170.D
8320-8325/8320CRP
.
NA
11
NE
01/14/20
.
DP
5 OF 5
INSTALLATION
5497
2020
FV
NOTES:
1. WHEN INSTALLING THIS UNIT, LOCAL , STATE, OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION DIMENSIONS
(LOCATIONS), WASTE AND SUPPLY REQUIREMENTS OTHER THAN SHOWN.
2. TO COMPLY WITH ANSI Z358.1-2014 FOR EMERGENCY EYEWASH OR EYE/FACE WASH:
- EYEWASH OR EYE/FACE WASH SHALL BE POSITIONED SUCH THAT FLUSHING FLUID PATTERN IS NOT LESS THAN 33" (838mm)
AND NO GREATER THAN 53" (1346mm) FROM SURFACE ON WHICH USER STANDS; AND 6.0" (153mm) MINIMUM FROM WALL
OR NEAREST OBSTRUCTION.
- SHOWER SHALL BE POSITIONED SUCH THAT SHOWER HEAD IS NOT LESS THAN 82" (2083mm) AND NO GREATER THAN
96" (2438mm) FROM SURFACE ON WHICH USER STANDS.
- SHOWER SPRAY PATTERN SHALL HAVE A MINIMUM DIAMETER OF 20" (508mm) AT 60" (1524mm) ABOVE SURFACE ON WHICH
USER STANDS, AND CENTER OF SPRAY PATTERN SHALL BE LOCATED AT LEAST 16" (406mm) FROM NEAREST OBSTRUCTION.
3 DO NOT USE REGULAR PIPE SEALANT. IF NECESSARY USE DOW CORNING 832 SEALANT PLACING FIVE SMALL BEADS ON THE
MALE THREADS, JUST ABOVE THE FIRST THREAD.
4. DIMENSIONS MAY VARY BY ±1/2" (13 mm).
L-STRAINER
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Haws Prodotto idraulico