HBM CFT+ Series Manuale utente

Operating Manual | Bedienungsanleitung |
Manuel d'emploi | Istruzioni per l'uso | 操说明
English Deutsch Français Italiano 文
CFT+

Hottinger Baldwin Messtechnik GmbH
Im Tiefen See 45
D-64293 Darmstadt
Tel. +49 6151 803-0
Fax +49 6151 803-9100
www.hbm.com
Mat.: 7-0111.0002
DVS: A05101_01_YCI_02 HBM: public
03.2019
EHottinger Baldwin Messtechnik GmbH.
Subject to modifications.
All product descriptions are for general information only.
They are not to be understood as a guarantee of quality or
durability.
Änderungen vorbehalten.
Alle Angaben beschreiben unsere Produkte in allgemeiner
Form. Sie stellen keine Beschaffenheits- oder Haltbarkeits
garantie dar.
Sous réserve de modifications.
Les caractéristiques indiquées ne décrivent nos produits
que sous une forme générale. Elles n'impliquent aucune
garantie de qualité ou de durabilité.
Con riserva di modifica.
Tutti i dati descrivono i nostri prodotti in forma generica e non
implicano alcuna garanzia di qualità o di durata dei prodotti
stessi.
变更权利。
所有息是对我品性描。在性或性方
它并提。

Operating Manual | Bedienungsanleitung |
Manuel d'emploi | Istruzioni per l'uso | 操说明
English Deutsch Français Italiano 文
CFT+

2A05101_01_YCI_02 HBM: public CFT+
English
1 Safety instructions 3........................................
2 Markings used 7............................................
2.1 The markings used in this document 7..........................
3 Scope of supply and equipment variants 8...................
3.1 Accessories 8...............................................
4 General application instructions 9...........................
5 Structure and mode of operation 10...........................
5.1 Force transducer operation 10..................................
6 Conditions on site 12........................................
6.1 Ambient temperature 12.......................................
6.2 Moisture and corrosion protection 12............................
7 Mechanical installation 13....................................
7.1 Important precautions during installation 13......................
7.2 General installation guidelines 14...............................
7.3 Force transducer installation 16.................................
7.3.1 Mounting with flange connection 16.............................
7.3.2 Mounting via the central fine thread 18...........................
7.3.3 Mounting with threaded bushing 19..............................
8 Electrical connection 21......................................
9 Specifications 22............................................
10 Dimensions 24..............................................

Safety instructions
CFT+ A05101_01_YCI_02 HBM: public 3
1 Safety instructions
Intended use
Piezoelectric force transducer in the CFT+ type series are designed solely for
measuring static and dynamic compressive forces within the load limits stated
in the specifications. Any other use is not the intended use.
To ensure safe operation, it is essential to comply with the regulations in the
mounting instructions, the safety requirements listed below, and the data
specified in the technical data sheets. It is also essential to observe the appli
cable legal and safety regulations for the relevant application.
Force transducers are not intended for use as safety components. Please also
refer to the "Additional safety precautions" section. Proper and safe operation
of force transducers requires proper transportation, correct storage, setup and
mounting, and careful operation.
Load carrying capacity limits
Comply with the information in the technical data sheets when using force
transducers. The respective specified maximum loads in particular must never
be exceeded. The following limits set out in the technical data sheets must not
be exceeded:
SForce limits
SLateral force limits
SBreaking forces
SMaximum eccentricity
SPermissible dynamic loads
STemperature limits
Please note that when several force transducers are interconnected, the load/
force distribution is not always uniform. This means that one particular force
transducer may be overloaded even if the total of all the nominal (rated) force
for all sensors has not been reached.

Safety instructions
4A05101_01_YCI_02 HBM: public CFT+
Use as machine elements
Force transducers can be used as machine elements. Note also the "Load-
carrying capacity limits" section and the specifications to ensure the required
overload limit of your application.
Accident prevention
The prevailing accident prevention regulations must be taken into account,
even though the breaking force is well in excess of the full scale value.
Additional safety precautions
Force transducers cannot (as passive transducers) implement any (safety-
relevant) cutoffs. This requires additional components and constructive
measures, for which the installer and operator of the plant is responsible.
In cases where a breakage or malfunction of the force transducer would cause
injury to persons or damage to equipment, the user must take appropriate
additional safety precautions that meet at least the applicable safety and ac
cident prevention regulations (e.g. automatic emergency shutdown, overload
protection, catch straps or chains, or other fall protection).
The electronics conditioning the measurement signal should be designed so
that measurement signal failure cannot subsequently cause damage.
General dangers of failing to follow the safety instructions
Force transducers are state-of-the-art and failsafe. Transducers can give rise
to residual dangers if they are mounted, installed, used and operated inap
propriately or by untrained personnel. Every person involved with setting up,
starting up, operating or repairing a force transducer must have read and un
derstood the mounting instructions and in particular the technical safety in
structions. Force transducers can be damaged or destroyed by non-designated
use of the force transducer or by non-compliance with the mounting and
operating manual, these safety instructions or other applicable safety
regulations when using the force transducers. A force transducer can break,
particularly in the case of overload. The breakage of a force transducer can
cause damage to property or injury to persons in the vicinity of the force trans
ducer.

Safety instructions
CFT+ A05101_01_YCI_02 HBM: public 5
If force transducers are not used as intended, or if the safety instructions or
specifications in the mounting and operating instructions are ignored, it is also
possible that a force transducer may fail or malfunction, with the result that
persons may be injured or property damaged (due to the loads acting on or
being monitored by the force transducer).
The scope of supply and performance of the transducer covers only a small
area of force measurement technology, as measurements with piezoelectric
force transducers presuppose the use of electronic signal processing.
Equipment planners, installers and operators should always plan, implement
and respond to the safety engineering considerations of force measurement
technology in such a way as to minimize residual dangers. Comply with
pertinent national and local regulations.
Conversions and modifications
The design or safety engineering of the transducer must not be modified with
out our express permission. Any modification shall exclude all liability on our
part for any damage resulting therefrom.
Maintenance
The force transducers of the CFT+ series are maintenance free.
Disposal
In accordance with national and local environmental protection and material
recovery and recycling regulations, old transducers that can no longer be used
must be disposed of separately and not with normal household garbage.
If you need more information about disposal, please contact your local
authorities or the dealer from whom you purchased the product.
Qualified personnel
Qualified personnel means persons entrusted with siting, mounting, starting up
and operating the product who possess the appropriate qualifications for their
function.
This includes people who meet at least one of these three requirements:

Safety instructions
6A05101_01_YCI_02 HBM: public CFT+
SYou know about the safety concepts of automation and as project person
nel, are familiar with these concepts.
SAs automation plant operating personnel, you have been instructed how to
handle the machinery. You are familiar with the operation of the equipment
and technologies described in this documentation.
SAs system startup engineers or service engineers, you have successfully
completed the training to qualify you to repair the automation systems.
Moreover, you are authorized to start up, ground and label circuits and
equipment in accordance with safety engineering standards.
It is also essential to comply with the legal and safety requirements for the rele
vant application during use. The same applies to the use of accessories.
The force transducer may only be installed by qualified personnel, strictly in
accordance with the specifications and with the safety requirements and regu
lations.

Markings used
CFT+ A05101_01_YCI_02 HBM: public 7
2 Markings used
2.1 The markings used in this document
Important instructions for your safety are specifically identified. It is essential to
follow these instructions in order to prevent accidents and damage to property.
Symbol Meaning
WARNING This marking warns of a potentially dangerous situa
tion in which failure to comply with safety require
ments may result in death or serious physical injury.
CAUTION This marking warns of a potentially dangerous situa
tion in which failure to comply with safety require
ments may result in slight or moderate physical injury.
Notice This marking draws your attention to a situation in
which failure to comply with safety requirements may
result in damage to property.
Important
This marking draws your attention to important infor
mation about the product or about handling the prod
uct.
Tip
This marking indicates tips for use or other informa
tion that is useful to you.
Information
This marking draws your attention to information
about the product or about handling the product.
Emphasis
See …
Italics are used to emphasize and highlight text and
identify references to sections, diagrams, or external
documents and files.

Scope of supply and equipment variants
8A05101_01_YCI_02 HBM: public CFT+
3 Scope of supply and equipment variants
SCFT+ piezoelectric force transducer
SMounting instructions
STest record
SPlug protection
STwo centering rings
SThreaded bushing
3.1 Accessories
The accessories are not included among the items supplied.
Accessories Ordering number
Connection cable for piezoelectric sensors with a 10-32UNF
plug on both sides. Available in different lengths up to 7 m 1-KAB143-x
Connection cable for piezoelectric sensors with a 10-32UNF
plug on both sides. Rugged design, mechanically protected with
a steel spiral on the sensor side. Available in different lengths up
to 7 m
1-KAB145-x
Connection cable for piezoelectric sensors with a 10-32UNF
plug on one side and a BNC plug on the other cable end.
Available in different lengths up to 3 m
1-KAB176-x
Cable coupling to extend piezoelectric connection cables. 10-32
UNF at both ends 1-CCO
Summing box for parallel connection of up to four piezoelectric
sensors to one charge amplifier. Connection sockets: 10-32UNF 1-CSB4/1