Installing Your T-POD Timer Kit
Hard-wired Pump Timer/ PumpJump™ on Your D/DX Series Digital HEAT SIPHON®
PART A - Mounting your T-POD
Tools Required:
Cordless Drill
Phillips Head Screw Driver
1
Chose a wall mounting location between your breaker box and pool pump and within 8-10 feet of your
Heat Siphon if possible (the 24 volt control wire can be extended as necessary). You will need free wall
space approximately 12 inches wide by 24 inches high to mount the T-POD and it
should be directly over or in line with the power wires going from your pool pump to
your AC power supply. T-POD comes with two 1/2” conduit nipples installed to permit
the use of conduit between the breaker and the pump.
2
Remove the T-POD cover from the base and fasten the base to the wall using the
TWO (2) mounting holes in the center sides of the base. Use appropriate fasten-
ers for the wall material - deck screws if wood or concrete anchor screws etc.
PART B - Power/ Pump Wiring
NOTE: It is strongly recommended that a Licensed
Electrician perform all Power Wiring
1
TURN OFF ALL POWER to your Pool Pump (circuit breaker) and prepare the wir-
ing to be cut and spliced or run new wire from your pump breaker/disconnect switch
to the T-POD and from the T-POD to the pump as shown.
2
Connect the two wires from the breaker to the two screw down terminals ON THE
RIGHT SIDE of the T-POD marked “FROM POWER LINE BREAKER”. This en-
sures that the T-POD’s 24 volt transformer will be powered all the time so the “ON OFF
AUTO” toggle switch will work properly and to enable the POD terminals on the Player
to complete the control circuit.
3
Connect the two POWER wires from your pool pump to the two screw down terminals ON THE LEFT
SIDE of the T-POD marked “FROM PUMP”.
NOTE: If the wrong terminals are used your T-POD will not turn on or function properly
PART C - Heat Siphon Control Wiring
Tools Required:
Small Flat Blade Screw Driver
Phillips Head Screw Driver
1
TURN OFF ALL POWER to your Heat Siphon (circuit breaker) and remove the
5 digital door screws. Tilt the door forward until you can access the back of the
Player board.
Remove Screws and tilt door forward
ACCESS HOLE FOR CONTROL WIRE