6
6. ASSOCIATION GROUPS
From a Controller’s point of view, Heatit Z-Water will consists of a root device and 14 endpoint devices - if the Controller is
supporting Multichannel devices, otherwise is only the root device seen by the Controller (endpoint 0).
The devices are:
• Root device; an intersection of all the devices (endpoint 0).
• 10 switch devices to control each of the relay outputs (endpoint 1 – 10).
• 4 sensor devices representing the analogue inputs (endpoint 11 – 14).
Below is an overview of all the devices and the association groups for each device.
The first number in the association group number indicates the group number for actual device, and the second number
is the group number on the root device (endpoint 0).
DEVICE 1 (ENDPOINT 1) RELAY OUTPUT 1
Group 1 / 1 Lifeline.
Sends Device Reset notifications and Basic Report On / O when relay output 1 is activated.
Max. nodes in the group: 5
DEVICE 2 (ENDPOINT 2) RELAY OUTPUT 2
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 2 is activated.
Max. nodes in the group: 5
DEVICE 3 (ENDPOINT 3) RELAY OUTPUT 3
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 3 is activated.
Max. nodes in the group: 5
DEVICE 4 (ENDPOINT 4) RELAY OUTPUT 4
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 4 is activated.
Max. nodes in the group: 5
DEVICE 5 (ENDPOINT 5) RELAY OUTPUT 5
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 5 is activated.
Max. nodes in the group: 5
DEVICE 6 (ENDPOINT 6) RELAY OUTPUT 6
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 6 is activated.
Max. nodes in the group: 5
DEVICE 7 (ENDPOINT 7) RELAY OUTPUT 7
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 7 is activated.
Max. nodes in the group: 5
DEVICE 8 (ENDPOINT 8) RELAY OUTPUT 8
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 8 is activated.
Max. nodes in the group: 5
DEVICE 9 (ENDPOINT 9) RELAY OUTPUT 9
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 9 is activated.
Max. nodes in the group: 5
DEVICE 10 (ENDPOINT 10) RELAY OUTPUT 10
Group 1 / - Lifeline.
Sends Basic Report On / O when relay output 10 is activated.
Max. nodes in the group: 5