6 KEY: No. 6 address number on/off, press No. 6 key, the machine
starts, press No. 6 key again, the machine stops; after pressing
No. 6 key, the machine runs for 8 seconds by default.。
7 KEY: Spark 1.5 seconds from 1-6 address once, time
interval is 0.5 seconds, cycle is 3 times, 1.5 seconds for
extension 1, 0.5 seconds for extension 2, 1.5 seconds for
extension 2, and 0.5 seconds for extension 2. Until
extension 6 sparks 1.5 seconds, waits 0.5 seconds;Then
start on the 1st and cycle three times.
8KEY: Spark 1.5 seconds from 6-1 address once, time
interval is 0.5 seconds, cycle is 3 times, spark 1.5 seconds
from extension 6, wait 0.5 seconds, spark 1.5 seconds from
extension 5, wait 0.5 seconds. Spark 1.5 seconds until
Extension 1, wait 0.5 seconds;Then start from No. 6 and cycle
three times (notice the commands here, for example, start
sparking No. 1, start sparking No. 2 0.5 seconds after No. 1 start,
then start No. 3 0.5 seconds, then start No. 4 0, 5 seconds, then
No. 1 has sparked 1.5 seconds, closed, and so on).Not required
for No. 1 to be sparked until No. 1 runs for 1.5 seconds and then
starts No. 2 in 0.5 seconds.
9 KEY: Spark 1.5 seconds, 1 second interval, 3 cycles, 1-6 spark 1.5 seconds, 1
second interval, 3 cycles, 1-6 spark 1.5 seconds, 1 second interval, 3 cycles.
10 KEY: Overall spark 30 seconds, 1-6 spark 30 seconds (no
matter which address, can receive sparking).
11KEY: The emergency stop command, all the machines receive
the command for stopping the sparking action and return to the
standby preheating state.
12 KEY: Cleaning, soft shutdown, press soft shutdown, stop all actions,
extinguish all indicators, only the cooling fan in work, the fastest reversal of the
first feeding, the fastest speed of the second feeding motor, the fastest speed of
the fan, heating stop, start timing, timing time to the extension execution
mechanism all stop, No. 1-6 shutdown, stop all actions, extinguish all indicators.
Only the cooling fan is working. Please press No. 12 key before cutting off the
power supply. Soft shutdown is needed for cooling. The temperature of the
display frequency will drop to about 250 degrees for about 6-8 minutes. It is
strictly prohibited to pull out the point source without starting No. 12 key. This will
damage the machine.