Herz clever&smart Room Controller Guida utente

CONTENT
Safety Instructions 3
EG-Conformity 3
General Instructions 3
Changes to the Unit 3
Warranty and Liability 4
Disposal and Pollutants 4
Description HERZ clever&smart Room Controller 5
Technical Data 5
Scope of Supply 5
Installation 6
HERZ clever&smart Room Controller installation 6
Operation 8
Room Overview 8
Operating Mode 9
Menu 9
Set Operation Hours 10
Set Operation Hours Example 10
Expert Menu 11
Settings 12
Devices 13
Rooms 14
Sensors 15
Service Values 16
Support 17
Notes 17
2
HERZ clever&smart Room Controller

Safety Instructions
EG-Conformity
By affixing the CE mark to the unit the manufacturer declares that the HERZ clever&smart Room Controller conforms to the following
relevant safety regulations:
lEU low voltage directive 2014/35/EU
lEU electromagnetic compatibility directive 2014/30/EU
lEU RoHS Directive 2011/65/EU
lEU WEEE Directive 2012/19/EU (Reg.nr. DE 23479719)
Conformity has been verified and the corresponding documentation and the EU declaration of conformity are kept on file by the
manufacturer.
General Instructions
Please read carefully!
These installation and operating instructions contain basic instructions and important information regarding safety, installation,
commissioning, maintenance and the optimal use of the unit. Therefore these instructions must be read and understood completely by the
installation technician/specialist and by the system user before installation, commissioning and operation of the unit.
This unit is an automatic, electrical Room Controller. Install the unit only in dry areas and under the ambient conditions described in
“Specifications”.
In addition, observe the applicable accident prevention regulations, the regulations of the Association of Electrical Engineering, the local
power supply utility, the applicable DIN-EN standards and the installation and operating instructions for the additional system components.
Installation, electrical connection, commissioning and maintenance of the device may only be carried out by an appropriately trained
specialist.
Users: Make sure that the specialist gives you detailed information on the function and operation of the unit. Always keep
these instructions in the vicinity of the unit.
The manufacturer does not take over any liability for damage caused through improper usage or non-compliance of this manual!
Before working on the unit, switch off the power supply and secure it against being switched on again! Check that there is no
power flowing! Electrical connections may only be made by a specialist and in compliance with the applicable regulations. The
unit may not be put into operation if there is visible damage to the housing, e.g. cracks.
Changes to the Unit
lChanges, additions to or conversion of the unit are not permitted without written permission from the manufacturer.
lIt is likewise forbidden to install additional components that have not been tested together with the unit.
lIf it becomes clear that safe operation of the unit is no longer possible, for example because of damage to the housing, turn
the Unit off immediately.
lAny parts of the unit or accessories that are not in perfect condition must be exchanged immediately.
lUse only original spare parts and accessories from the manufacturer.
lMarkings made on the unit at the factory must not be altered, removed or made illegible.
lOnly the settings described in these instructions may be set using the Unit.
Changes to the unit can compromise the safety and function of the unit or the entire system.
HERZ clever&smart Room Controller
3

Warranty and Liability
The Unit has been manufactured and tested with regard to high quality and safety requirements. The warranty and liability shall not
include, however, any injury to persons or material damage that is attributable to one or more of the following causes:
lFailure to observe these installation and operating instructions
lImproper installation, commissioning, maintenance and operation
lImproperly executed repairs
lUnauthorised structural changes to the unit
lUse of the device for other than its intended purpose
lOperation above or below the limit values listed in the ‚Specifications‘ section
lForce majeure
Disposal and Pollutants
The unit conforms to the European RoHS 2011/65/EU for the restriction of the use of certain hazardous substances in electrical and
electronic equipment.
For disposal, according to the WEEE Directive 2012/19/EU, the device does not belong in household waste under any
circumstances. Dispose of the unit only at appropriate collection points or ship it back to the seller or manufacturer.
4
HERZ clever&smart Room Controller

Description HERZ clever&smart Room Controller
Technical Data
Housing
2-part, ABS plastic
75 mm x 95 mm x 19 mm
Glass front
Display
Capacitive touch panel
Color display with 240x320 dots
2.8 inches (7 cm) diagonal
Operation Intuitive user guidance
Language 20 menu languages selectable
Electrical specifications:
Power Supply 24 VDC +/- 10 %
Power consumption max. 2,5 W
Protection Class IP 20
Protection class / overvoltage category III / I
Permissible Ambient Conditions
during operation 0 °C - 50 °C, no moisture condensation permitted
for transport/storage 0 °C - 60 °C, no moisture condensation permitted
Measurement Range Outside the measuring ranges there are larger deviations
Internal temperature sensor 0 °C - 60 °C Accuracy +/- 1 °C
Resolution 0,1 °C
After switching on or disconnecting from the mains, it takes up to 60 minutes until the temperature is displayed precisely.
Other Specifications
Installation Methods Wall installation, with/without wall socket
Real Time Clock RTC with 24 hour power reserve
Scope of Supply
lHERZ clever&smart Room Controller
l2 screws 3,5 x 35 mm and 2 plugs 6 mm for wall installation.
lTerminating resistor (120 Ohm) pre-installed on one of the two CAN High/CAN Low connections, operating tool, switch
box
lHERZ clever&smart Room Controller installation guide
HERZ clever&smart Room Controller
5

Installation
HERZ clever&smart Room Controller installation
Mount the unit at a suitable location.
Pay attention to suitable environmental conditions. Direct sunlight, sources of
heat and cold, e.g. radiators and windows must be avoided.
Recommended connection cable: twisted pair cable with shield, e.g. bus cable
3 × 2 × 0,22 mm². Strip cables, slip protective conductor over, and remove fill material as
needed.
When wall mounting, make sure that the cables are kept as short as possible (max. 40 mm
for direct wall mounting), as unnecessary vein loops in the HERZ clever&smart Room
Controller housing can lead to problems.
When mounting on a switch box, make sure that the cables are kept as short as possible
(strip cables max. 55 mm) and that any vein loops are fed back into the switch box, as
unnecessary vein loops in the HERZ clever&smart Room Controller housing can lead to
problems.
Strip the last 8 - 9 mm of the wires. Isolate shielding and connect it at a suitable location
(controller or CAN-box) to the protective conductor.
Any contact between protective conductor and circuit board can cause serious
damage.
Mounting on plastic wall socket
Fasten the base to the switch box with the enclosed screws (3.0 x 16 mm).
Direct wall mounting
Hold the lower part of the housing up to the selected position and mark the three mounting
holes. Make sure that the wall surface is as even as possible so that the housing does not
become distorted when it is screwed on. Using a drill and drill holes at the points marked on
the wall and push in the plugs. Insert screws and screw it in slightly. Align the base and
tighten the screws.
6
HERZ clever&smart Room Controller

* Only available on Clima version!
Open the connection terminals with the accompanying operating tool and make the
electrical connection (24 VDC, GND, CAN-High and CAN-Low) as described in the
operating manual of the Control Box.
Power supply 24 VDC, ensure correct polarity or it may cause damage to the
unit!
For the pin assignment of the CAN bus line on the HERZ clever&smart Control Box, please
refer to the corresponding instructions for use or operating manual.
Place the control panel on the lower part of the housing as illustrated in the picture and fix it
in place with the screw supplied.
Switch on the mains voltage of the Control Box and put the HERZ clever&smart Room
Controller into operation.
The setup wizard can be accessed at any time in HERZ clever&smart Room
Controller under the menu item 'Expert'.
HERZ clever&smart Room Controller
7

Operation
Room Overview
Displays the room temperature and outdoor temperature after activating the start screen.
Room icon
Selecting a room icon
takes you to the room temperature
settings.
Outdoor temperature
Displayed as soon as an outdoor
sensor is used or an outdoor sensor is
activated on a HERZ clever&smart
Control Box menu "Expert > Control
Box > Heating circuit > Sensor
outdoor".
Multiroom selection
By dragging your finger vertically
across several rooms, you can change
the operating mode in all rooms at the
same time.
°C
Room temperature
Current room temperature.
8
HERZ clever&smart Room Controller

Operating Mode
Overview > Operating Mode
Back/ Forward
Navigate back to the overview.
Room
Displays the selected space.
Reference temperature
Setting the reference temperature for
the active operating mode in the
displayed room.
Menu
Navigate to the main menu
Operating Modes
The operating mode shown in colour
is currently active and can be changed
by selecting another mode. Manually
selected modes remain active until the
next change of mode by the timer
program. A background frost
protection function remains active in
the "off" mode.
Menu
Overview > Operating Mode > Menu
Holiday
Set the period and temperature for a
longer absence.
Timer
Setting of individual heating or cooling
times for each day of the week with
copy function for subsequent days.
Expert
Advanced settings for the technician.
HERZ clever&smart Room Controller
9

Set Operation Hours
Overview > Operating Mode > Menu > Timer
Setting of individual heating and cooling times for the selected room.
Operating Modes
Selection of the operating mode to
select individual heating or cooling
sections.
Clock
Time table of the selection in periods
of 30 minutes increments.
Touch individual segments, or drag
your finger over complete time
intervals to colour them according to
the selected operation mode.
Menu
Opens the copy function. The function
allows you to copy the heating and
cooling times to the following day, to
Monday - Friday or to Monday -
Sunday.
Back / Next Weekday
Selects the set day.
Set Operation Hours Example
Step 1
Use the arrow keys to select the
desired day.
Step 2
Select the desired mode (Normal,
Comfort, Eco or Off) and then
move your index finger over the
desired time period. The selected
period changes colour to the
colour of the selected operating
mode after selection. Set the
times of the other operating
modes in the same way.
Step 3
After completing the setting of the
individual heating times, you have
the option of copying the times via
the main menu to the following
day, to Monday - Friday or to
Monday - Sunday or to set them
individually for each day of the
week.
In the interests of efficient and energy-saving single room control, the operating times should be set specifically for each room.
10
HERZ clever&smart Room Controller
Altri manuali per clever&smart Room Controller
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Herz Controllori

Herz
Herz clever&smart Control Box Heating Manuale utente

Herz
Herz F 7713 01 Manuale utente

Herz
Herz clever&smart Control Box Clima Guida utente

Herz
Herz 7708 Series Manuale utente

Herz
Herz clever&smart Room Controller WiFi Guida utente

Herz
Herz clever&smart Control Box Clima Manuale utente

Herz
Herz clever&smart Control Box Heating Guida utente

Herz
Herz clever&smart Room Controller Clima WiFi Guida utente