Statutory Regulations (Install Codes)
The installation of this appliance must be carried out by a properly trained and qualified installer and in
accordance with the relevant regulations, codes of practice and the related publications of the Country, State,
County and City of destination.
United States of America
1) Local Codes
2) In the absence of local codes, installation must conform to the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
Copies may be obtained from the American Gas Association, Inc., on their web site:
http://www.aga.org/
3) National Electrical Code, ANSI/NFPA-70, or latest edition. Copies may be obtained from the
National Fire Protection Association, on their web site: http://www.nfpa.org/
4) Vapor Removal From Cooking Equipment, NFPA-96, or latest edition. Copies may be obtained from
the National Fire Protection Association, on their web site: http://www.nfpa.org/
Canada
1) Local Codes
2) CSA B149.1 Natural Gas and Propane Installation Code.
3) CSA C22.1 Canadian Electrical Code
4) CSA C22.2 Canadian Electrical Code
Canadian codes can be found on the CSA website: http://www.csa.ca
Gas Supply
The local gas authority should be consulted at the installation planning stage in order to establish the availability
of an adequate supply of gas and to ensure that the meter is adequate for the required flow rate. The pipe work
from the meter to the appliance must be an appropriate size.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as a means of
isolating the appliance for emergency shut off and for servicing. A union or similar means of disconnection must
be provided between the gas-cock and the appliance.
A manually operable valve must be fitted to the gas supply to the kitchen to enable it to be isolated in an
emergency. Wherever practical, this shall be located either outside the kitchen or near an exit in a readily
accessible position.
Where it is not practical to do this, an automatic isolation valve system should be fitted which can be operated
from a readily accessible position near the exit.
In locations where the manual isolation valve is fitted or the automatic system can be reset this notice must be
posted:
“ALL DOWNSTREAM BURNER AND PILOT VALVES MUST BE TURNED OFF PRIOR TO
ATTEMPTING TO RESTORE THE SUPPLY. AFTER EXTENDED SHUT OFF, PURGE
BEFORE RESTORING GAS”
NOTE: Before assembly and connection, check gas supply.