damaged
Need change the controller circuit
board.
E1 The light in the sauna room
is damaged.
The light in the sauna room
is damaged, no lighting.
Need change the light in the sauna
heating tube.
E3 Button scan is damaged. There is no reaction when
push the controller button.
Need change the controller circuit
board.
E4 Open circuit in temperature
detector connection.
Open circuit in temperature
detector connection.
Need check the cable connection
of the temperature detector, and
make sure the connection is right.
E5
short circuit in the
temperature detector
connection.
short circuit in the
temperature detector
connection.
Need check the cable connection
of the temperature detector, and
make sure the connection is right.
E6
Temperature detector enter
the ultra-high temperature
protection.
The temperature of the
sauna room is too high.
The sauna heater will stop heating
and cut off the power
automatically, once the detected
temperature lower than 120℃, the
machine can restart work.
E7 Sauna room enter the ultra-
high temperature protection
The temperature of the
sauna room is too high.
The sauna heater will stop heating
and cut off the power
automatically, once the detected
temperature drops to 120℃, the
machine can restart work.
E8
The temperature detection
in the sauna room is
damaged.
The temperature detection
in the sauna room is
damaged.
Need change the temperature
detection.