9. Operating procedure
CAUTION!
OIL MUST NOT BE POURED INTO THE BURNER IF
THE CHAMBER OR THE PAN IS STILL HOT!!! ALWAYS WAIT
UNTIL THE BURNER HAS COOLED DOWN. NON-COMPLIANCE
WITH THE ABOVE WARNING MAY CAUSE EXPLOSION OF OIL
VAPOURS AND BURNS!!!
How to operate the device
Once engaged, the heater switches to desired modes depending on settings chosen by the user
and information transmitted by sensors connected to the control panel.
If necessary, water may be poured from the tank and replaced with used oil.
Plug into the power socket (230V/50Hz).
Pull the upper part of the cover aside and take the burner lid off, take the cylinder and the ring
out (if necessary, clean thoroughly the vaporising pan and its base, the burner, cylinder and ring).
Check if the vaporising pan is cool and clean, and then pour approximately 250 ml of heating or
diesel oil onto it.
Light oil using a piece of scrunched up paper that needs to be put on fire and thrown onto the
vaporising pan.
Install ring and cylinder, put the burner lid back on, close the upper part of burner’s casing.
Press Start button on the control panel (green diode turns on)
After approx. 10-15 minutes, depending on the temperature in the room, the fuel pump and
ventilation fan will start and the yellow pump diode will turn on at the same time. The heater
starts working on the lowest gear with lower performance and can continue operating in this
mode on a continuous basis:
15 kW; 1.25 kg/h –HP-115 and
22 kW; 1.85 kg/h –HP-125
The second gear, with increased performance can be activated (“+” on the screen) after 30
minutes following the activation of the heater:
22kW; 1.85 kg/h –HP-115 and
30 kW; 2.55 kg/h –HP-125
Each time Stop button is pressed followed by pressing the Start button during operation will
result in switching into the Heating up mode of the burner.
Shutting off
Press Stop on the control panel (yellow diode goes off), pump stops feeding fuel onto the
vaporising pan, and ventilation fan works only until the burner has cooled off.
The device must not be unplugged for as long as the ventilation fan is working, this can be done
only after the burner has cooled down. The burner switches off automatically. Please remember
that after switching off the device, the cast-iron pan remains hotter for longer (depending on the
temperature in the room) and the heater cannot be re-engaged until it cools down completely.