Hocom JDC Series Manuale utente

User Manual
JDC
Series
Digital Counting Scale

JDC-Counting Scale
User Manual
Cautions
Upon receiving the scale, please take at least 8
hours to recharge the battery before you start to
operate this scale.
Please recharge the battery after a long period of
storage (more than one month). It takes 8~10
hours to fully recharge the battery.
Please assemble the platter before powering on the
scale.
Do not keep the weight placed on the platter for a
long period.
Keep the scale away from the environment with
high temperature, high humidity, heavy press,
and heavy bump.
Always make sure the scale is located in a flat
and plane surface.
1

JDC-Counting Scale
User Manual
Dimensions
JDC
2

JDC-Counting Scale
User Manual
Symbols on LCD
Zero Indication ():
Cursor appears on the bottom edge of WEIGHT
LCD (above of ZERO printed on the display-overlay),
and indicates the scale is at zero-point.
NET Weight Indication ():
Cursor appears on the bottom edge of WEIGHT
LCD (above of TARE printed on the display-overlay),
and indicates the tare weight has been deducted.
Accumulation Indication ():
Cursor appears on the bottom edge of QUANTITY
LCD (above of M+ printed on the display-overlay),
and indicates the memory bank has stored
accumulative data of total weight and total quantity.
Insufficient Sampling-Quantity Indication ():
Cursor appears on the bottom edge of UNIT
WEIGHT LCD (above of S.Q printed on the
display-overlay), and indicates the sampling-quantity
(setup via SAMPLE key) is less than 10 pieces. The
more sampling-quantity on the platter, the scale
could calculate more precise unit weight.
3

JDC-Counting Scale
User Manual
Insufficient Unit Weight Indication ():
Cursor appears on the bottom edge of UNIT
WEIGHT LCD (above of S.W printed on the
display-overlay), and indicates the averaging unit
weight is too light.
The internal resolution of this scale is 3000. While
the averaging unit weight of measured subjects is
lighter than “max capacity / 3000”, cursor will
flash on UNIT WEIGHT LCD. For example:
With 15kg max capacity; and the internal resolution
is 3000. 15kg / 3000 = 5g. If the averaging unit
weight of measured subjects is lighter than 1g,
cursor will flash on UNIT WEIGHT LCD (above of
S.W printed on the display-overlay).
Operation Instructions
Battery Symbol ():
When WEIGHT LCD indicates and the scale
sounds beep for four times, it means the battery is
running in low-voltage status. LCD will indicate
continuously for reminding the user to recharge the
battery. If the battery is still running in low-voltage
status without being recharged, WEIGHT LCD will
indicate -OFF-and the scale will sound beep for
eight times. Please power off the scale and
-
-
4
-

JDC-Counting Scale
User Manual
recharge the battery (refer to page 10) as soon as
possible.
0
~
9
:
Press these keys to key in the unit weight or
sampling-quantity.
:
(1) Press this key to set the decimal point for the weight.
(2) Press and hold [] key till the scale sounds beep to
enable or disable optional Backlight.
CE
:
Press this key to delete the setting of weight value.
ZERO
:
Press this key to zero the weight. WEIGHT LCD will
show cursor on the above of ZERO (printed on the
display-overlay).
TARE
:
Press this key to deduct the tare weight. Put the
package or container on the platter and then press
[TARE] key. cursors will flash on WEIGHT LCD
(above of TARE and ZERO).
M+
:
Press this key could save the measured weight and
quantity values into the memory bank (up to 99 data
5

JDC-Counting Scale
User Manual
accumulation). Please notice the M+ function must
be operated under the same unit weight.
MR
:
Press this key to recall the data one by one that is
saved in the memory bank. After the last item of
saved data is recalled, pressing [MR] key again will
show the total accumulative values of total weight
(on WEIGHT LCD) and total quantity (on QNANTITY
LCD).
MC
:
Press this key to delete all accumulated data in the
memory bank (the scale will sound beep beep and
WEIGHT LCD will flash CLR when [MC] key has been
operated.
SAMPLE
:
Press this key to confirm the sampling quantity.
Example:
Put 500pcs of screws on the platter; then key in 500;
then press [SAMPLE] key once, the scale will
calculate the averaging unit weight of 500 screws
and show the value on UNIT WEIGHT LCD.
While putting another more pieces (less than 500pcs)
of screws on the platter, the scale will re-calculate
the averaging unit weight (UNIT WEIGHT LCD will
clear the original value and then show the updated
6

JDC-Counting Scale
User Manual
value). Please do NOT remove any thing from the
platter till the updated value of averaging unit weight
has been displayed.
WS
:
Press this key is to set the value of unit weight. We
suggest the unit weight should be heavier than the
division (or sensitivity) of the scale. For GRC-30kg x
5g, the unit weight should not be lighter than 5g.
ALARM
:
1. Press [ALARM] once to On/Off Alarm function.
2. Select Alarm Mode (WEIGHT/PCS) :
<1>Press and hold [ALARM] until UNIT
WEIGHT LCD show WEIGHT (or PCS).
<2> Press [TARE] to switch modes.
3. Select Alarm Range(Hi/Lo/In/Out):
<1>Under selected Alarm Mode, press and hold
[ALARM] until WEIGHT LCD show PCS(or
WEIGHT) and UNIT WEIGHT LCD show
hi/Lo/in/out options. Press [TARE] to select
Range.
<2> Press and hold [ALARM] to enter Alarm
Range setting.
WEIGHT LCD show original value
UNIT WEIGHT LCD show new value
QUANTITY LCD show setting Range
7

JDC-Counting Scale
User Manual
<3> Input new setting value, press and hold
[ALARM] to save new setting.
Example: setup 5 lb as the over-weight limit.
1. Press [ALARM]once to select Alarm On.
WEIGHT LCD show On for a while.
2. Press and hold [ALARM] until UNIT WEIGHT
LCD show current Mode. Press [TARE] to
switch modes, when UNIT WEIGHT LCD show
WEIGHT, press and hold [ALARM] again to
enter WEIGHT Mode
WEIGHT LCD show WEIGHT.
UNIT WEIGHT LCD show HI
3. Press and hold [ALARM] to enter range setting.
Enter over-weight limit value, press and hold
[ALARM] to confirm new setting.
WEIGHT LCD show
0
UNIT WEIGHT LCD show 5.00
QUANTITY LCD show -HI-
!!
Notice:When the total measured weight is
≧
5 lb, the scale will sound beep continuously.
-Lo-
-Hi-
0
Max
out
in
out
8

JDC-Counting Scale
User Manual
Example: Setting Alarm when PCS In 50~100:
1. Press [ALARM]once to select Alarm On.
WEIGHT LCD show On for a while.
2. Press and hold [ALARM] until UNIT WEIGHT
LCD show current Mode. Press [TARE] to
switch modes, when UNIT WEIGHT LCD show
PCS, press and hold [ALARM] again to enter
PCS Mode
WEIGHT LCD show PCS.
UNIT WEIGHT LCD show in
3. Press and hold [ALARM] to enter range setting.
Enter Lo-PCS limit value 50, press and hold
[ALARM] to confirm new setting.
WEIGHT LCD show
0
UNIT WEIGHT LCD show 50
QUANTITY LCD show -LO-
Enter Hi-PCS limit value 100, press and hold
[ALARM] to confirm new setting.
WEIGHT LCD show
0
UNIT WEIGHT LCD show 100
QUANTITY LCD show -HI-
!!
Notice:When the total measured PCS is
≧
50
and
≦
100, the scale will sound beep continuously.
9
Indice
Altri manuali Hocom Scala

Hocom
Hocom EQC Series Manuale utente

Hocom
Hocom EQW Series Manuale utente

Hocom
Hocom SSW Series Manuale utente

Hocom
Hocom GRC Series Manuale utente

Hocom
Hocom SSPX Manuale utente

Hocom
Hocom GRW Series Manuale utente

Hocom
Hocom SDW Series Manuale utente

Hocom
Hocom TAP Series Manuale utente

Hocom
Hocom GRP Series Manuale utente

Hocom
Hocom AEPL-M Series Manuale utente



















