Huato S500 Series Manuale utente

User’s Guide
S500 Series Temperature &
Humidity Data Logger
S500
E-mail: [email protected]
Talk to our sales
and shop online at
www.huato.cn

The information contained in this document is believed to be correct, but HUATO accepts no liability for any errors it contains, and reserves
the right to alter specifications without notice.
HUATO HUATO ELECTRIC CO., LTD.
Toll-Free: 0755-29977605
Customer Service: 0755-29977605
Engineering Service: 0755-29977605
Fax: +86-755-29748856
E-mail: [email protected]
Headquarters:
For Other Locations Visit www.huato.cn

Table of
Contents
Table of Contents
Section
..................................................................................................................................
Page
Section 1 Introduction .....................................................................................
1.1 Features ..............................................................................................
1.2 Applications .........................................................................................
1.3 Data Logger Model ...............................................................................
1.4 S500-EX/TH/ET/DT- USB DataLogger Appearance ............................
1.5 S500-EX/TH/ET/DT-RS485Data Logger Appearance ........................
1.6 LCD Temperature and Humidity Data Logger Screen .........................
1.7 Button function instructions ...................................................................
Section 2 S500-EX/TH/DT- USB Software Installation ........................
2.1 USB Install Driver & Software ..............................................................
2.2 Use of Logpro software ......................................................................
Section 3 S500-EX/TH/ET/DT-RS485 Software Installation ...............
3.1 Use of ToMonitor real-time monitoring software ..................................
3.2 Check the Save File in File List ..........................................................
Section 4 Attention .....................................................................................
4.1 Attention ................................................................................................
4.2 FAQ ....................................................................................................
1
1
1
1
2
3
4
5
6
6
7
10
10
13
16
16
16

• High-end integrated temperature & humidity sensors with original calibration.
• Built-in storage, up to 43,000 groups of temperature & humidity data.
• High accuracy in measuring temperature & humidity.
• Temperature, humidity and time are displayed simultaneously. Easy to operate with buttons.
• Built-in sound and light alarm, triggers when data value exceeds the thresholds. Simple and
elegant appearance, can be placed on the desk or mounted on the wall.
• Easy to use professional analysis software. Multiple data protection mechanism.
Widely used in medicine, electronics, transportation, warehousing, scientific research institutes,
meteorology, professional labs,museums, libraries, meteorological departments, etc.
Section 1 Introduction
1.1 Features
1.2 Applications
1.3 Data Logger Model
1
Introduction
1
Model
Temperature & Humidity
Temperature
Dual Temperature
Measuring
Accuracy
Measuring
Rang
43000
43000
43000
Sensor
type
Dual
External
Internal
External
Internal
External
Internal
External
Internal
External
Internal
External
Internal
External
S500-TH
S500-EX
S520-TH
S520-EX
S580-TH
S580-EX
±0.5℃/± 5%RH
±0.5℃/± 5%RH
±0.3℃/± 3%RH
±0.3℃/± 3%RH
±0.2℃/± 2%RH
±0.2℃/± 2%RH
-20~70℃/ 0~100%RH
-40~85℃/ 0~100%RH
-20~70℃/ 0~100%RH
-40~85℃/ 0~100%RH
-20~70℃/ 0~100%RH
-40~85℃/ 0~100%RH
S500-T
S500-ET
S520-T
S520-ET
S580-T
S580-ET
±0.5℃
±0.5℃
±0.3℃
±0.3℃
±0.2℃
±0.2℃
-20~70℃
-40~85℃
-20~70℃
-40~85℃
-20~70℃
-40~85℃
S500-DT
520-DT
±0.5℃
±0.3℃
-40~85℃
-40~85℃
Record
Volume

1.4 S500-EX/TH/ET/DT- USB Data Logger Appearance
2
Introduction 1
1
2
3
4
5
6
S500 Intelligent Data Logger II
Temperature&Humidity
MENU MAX
MIN OK
LOG
记录 MEM
储存 7
8
91 0 11
11
① LCD Screen
② ON/OFF Button
③ Backlight Button
④ Max or Min value and normal state switch button
⑤ Log ON/OFF
⑥ Hanging hole
⑦ Stand
⑧ S/N
⑨ Reset
⑩ USB
DC 12V

1.5 S500-EX/TH/ET/DT-RS485Data Logger Appearance
Introduction
1
3
11
① LCD Screen
② ON/OFF Button
③ Backlight Button
④ Max or Min value and normal state switch button
⑤ Log ON/OFF
⑥ Hanging hole
⑦ Stand
⑧ S/N
⑨ Reset
⑩ USB
DC 12V
1
2
3
4
5
6
S500 Intelligent Data Logger II
Temperature&Humidity
MENU MAX
MIN OK
LOG
记录 MEM
储存 7
8
91 0 11

1.6 LCD Temperature and Humidity Data Logger Screen
Introduction 1
4
MEM
储存
Icon Explanation
Backlight light
Alarm indicator. When the real-time value of temperature & humidity exceeds
the set upper and lower threshold, an alarm symbol will be displayed
Humidity display
Button lock/unlock
DC 12V external power supply
This symbol shows that the instrument is logging
Storage capacity, 4250 is the number of current records
Battery level indicator. When the area is full black, it indicates that the battery leve
l is sufficient. If it is empty, it means the battery is low and should be replaced
This symbol shows that the instrument has been connected to the computer and
data can be downloaded at this time
This symbol shows that the instrument only displays the upper threshold of the
temperature and humidity alarm value
This symbol shows that the instrument only displays the lower threshold of the
temperature and humidity alarm value
Display year, month and time one by one, 15 seconds for year information,
another 15s for month information, and then 30s for time information
Temperature display
MEM
储存

Put the attached software CD into the CD drive of the computer, find the file. Choose
right driver version according to the operating system:
For Win7, Win8, Win10 - 64 bits operating systems choose "CH341SER[64bit]"
For Win XP; Vista; Win7 - 32 bits operating system choose "CH341SER[32bit]".
Section 2 S500-EX/TH/DT- USB Software Installation
1.7 Button function instructions
2.1 Install USB Driver & Software
2.1.1 Click [CH341SER]
5
Installation and Instruction
2
LOG button, turn logging ON/OFF
MAX/MIN button
Backlight button
Power button
(1) In the non-logging mode (standby), press to enter the logging mode, LOG
indicator and the number of current records will be displayed on the LCD.
(2) In the logging mode, press this button to exit the logging mode, LOG indicator
and the number of current records will disappear.
In normal working mode, press this button to view the maximum/minimum
measurement value and the upper/lower alarm thresholds.
In normal working mode, press this button to turn on/off the backlight.
In the power-off state, click this button to turn on the instrument. In the
power-on state, turn off the logging function first, and then press this
button to turn off the instrument.
Note: Press at the same time to lock/unlock the keys.

After the installation is complete, connect the instrument to the computer through the attached
data cable to check whether the new port number can be found.
The steps to check the new port number are as follows:
2.1.2 Click
2.1.3 Right-click the [My Computer] icon-[Manage
(G)]-[Device Manager]-as shown below:
6
Installation and Instruction
2
Installation
OK
Device
Manager Port
Icon

Note: If the port number cannot be found in the above operation, please shut down the
computer and restart to try it again.
(1) Copy the software folder in the attached CD-ROM to the computer and create a desktop
shortcut. Connect the instrument to the computer when it is turned on.
(2) Run the software, enter the software interface, connect the instrument with USB interface,
click the connection button in the menu bar, and the [Communication Settings] dialog will pop up.
Check the port number under [Computer Management]-[Device Manager]-[Port]. Select the port
number of CH340 or CH341. Set 115200 or 38400 baud rate, click [Confirm] button to connect.
The operation buttons of disconnection, setting, download, delete, etc. will be enabled after
connection established.
2.1.4 Next, double-click [Port (COM and LPT)] to check the port number
like CH340 or CH341 as shown in the figure below:
2.2 Use of Logpro software
Installation and Instruction 2
7
Port
number
Port
number
Port
number
Altri manuali per S500 Series
1
Indice
Altri manuali Huato Registratore di dati

Huato
Huato HE17 Series Manuale utente

Huato
Huato S500 Series Manuale utente

Huato
Huato HE173 Manuale utente

Huato
Huato S1500 Series Manuale utente

Huato
Huato S1500 Series Guida rapida

Huato
Huato S400W Series Manuale utente

Huato
Huato S220-T8 Series Manuale utente

Huato
Huato S300-E Manuale utente

Huato
Huato S100 Series Manuale utente

















