ICRealtime VTO Manuale utente

Digital Bidirectional Talk System
Installation Guide
V1.2.0

Chapter 1 System Structure
VTO and VTH are connected as a tree. VTO has a 12V DC adaptor supplying it with
power while switch has a 24V DC adaptor supplying it with power.VTO and VTH are
connected via switch. The switch supplies VTH with power via network cable. Electric lock,
magnetic feedback, door sensor and unlock button all can be connected to VTO, but the
VTO does not supply them with power. An example for system framework. See Figure 1-
1.
Figure 1- 1

Chapter 2 Notifications
1. Please avoid the following interferences:
As an example.
Direct sunlight Rain Strong electricity Fire
2. Power adaptor voltage:
Input voltage 100V-240V~50-60HzAC; output voltage: 12V DC
Input voltage 100V-240V~50-60HzAC; output voltage: 24V DC
3. Cable
According to distance LNbetween VTO and VTH, select cable.
Cable
0< LN ≤50m
50< LN ≤100m
UTP Cat5e/Cat6:10 ohm/100m
Ok
Ok
UTP Cat5e/Cat6:18.8 ohm/100m
Ok
Not ok
We do not recommend LNover 100m.
4. Power line
According to distance LCbetween adaptor and VTO, select power line.
Power line
0< LC ≤30m
30< LC ≤100m
20AWG
Ok
Not ok
18AWG
Ok
Ok
17AWG
Ok
Ok
Note: Before plug in, please make sure + and –end are correctly matched to
power end.
5. Device and embedded box
Device
Embedded box
IH-6310
IH-6311
86 box /120 box
IH-D7710Z
IH-D7711Z
86 box

Chapter 3 FAQ
Q:I cannot boot up device.
A:
1. Check if the device is plugged into power. Digital VTO requires power voltage of
10V~15V.
2. If VTH is supplied with power by 2-pin port, check VTH’s power supply. It requires
voltage of 10V~15V.
3. Check if network cable is loosened. Switch supplies VTH with power of 22V~26V.
Q:VTO cannot call VTH.
A:
1. Check if VTH has registered on VTO.
Q:Low volume.
A:
1. Adjust VTO volume and call volume with VTH.
Q: VTH has no video or video quality is poor.
A:
1. In VTO web interface, switch video format to WVGA.
2. Do not place VTO under poor light or direct sunlight.
Q: I cannot unlock.
A:
1. You need to check if Model VTO supports swiping card to unlock.
2. Check if VTO access control module connection is loosened.
3. Electric lock is not correctly connected, or has no voltage output or output is too low.
Q: Door sensor alarm.
A:
1. Check if door is stuck.
Q: I cannot issue card. (For device with card swiping function only)
A:
1. VTO must support card issuing and card swiping.
2. Use IC card only.
.

Chapter 4 Installation Test
Note: The adaptor is not connected to city power grid in step 1-2.
4.1 Install VTO
4.1.1 Connect wire in embedded box to VTO
Step 1 Definition of ports:
The switch is connected to VTO’s network port.
Figure 4- 1
01. Network port: to external switch (IN port)
02. 3-pin 1: to lock control end 1
03. 3-pin 2: to lock control end 2
04. Power port: to input 12V DC power
05. Test port: to test device port
See Figure 4- 1.
General types of lock in market are unlocking with power and unlocking without power.
Here make electric lock and Magnetic lock as example.
Step 2 Install electric lock and unlock button
Figure 4- 2

1. When connect VTO to electric lock, make electric lock + toward VTO NO-end
(02.3-pin 1) and electric –toward VTO COM-end (02.3-pin 3).
2. When connect VTO to unlock button, make unlock button’s one end toward VTO (03.
3-pin 2) ALM 2-end and unlock button’s other end toward VTO (03.3-pin 3) GND-end.
See Figure 4- 2.
Step 3 Install door sensor
Figure 4- 3
1. When connect VTO to door sensor, make door sensor + toward VTO (02.3-pin 2)
NC-end and door sensor –toward VTO (02. 3-pin 3) COM-end.
2. When VTO is connected to door sensor for its magnetic feedback, make magnetic
feedback’s one end toward VTO (03. 3-pin 1) ALM1-end to unlock and make magnetic
feedback’s other end toward VTO (03. 3-pin 3) GND-end.
See Figure 4- 3.
Step 1 Definition of ports:
VTH can be connected to any port on VTO.
Figure 4- 4
01. Power port: to input DC 12V.
02. Lock port: to access control module
03. Network port: to switch (switch IN port)

See Figure 4- 4.
Step 1. Port definition is shown in Figure 4- 5.
Switch is at VTO network port.
Figure 4- 5
01. 10-pin port: connect to door lock, sensor feedback and unlock button. And provide
reserved port for other devices.
02. Power port: to input 12V DC power.
03. Network port 1: insert cable (RJ45 crystal head).
Step 2. Install electric lock and unlock button. See Figure 4- 6.
Figure 4- 6
When Villa VTO connects to electric lock, electric lock’s positive end connects to NO-end
(10-pin port 2)of villa VTO and electric lock’s negative-end connects to COM-end (10-pin
port 1)of villa VTO.
Villa VTO connects to unlock button, and unlock button’s one end connects to ALM1-end
(10-pin port 5) of villa VTO, unlock button’s other end connects to GND-end (10-pin port 4)
of villa VTO.
Step 3. Install door sensor lock. See Figure 4- 7.

Figure 4- 7
When villa VTO connects to door sensor lock, positive end of door sensor lock connects to
NC-end(10-pin port 3) of villa VTO and negative end of door sensor lock connects to
COM-end (10-pin port 1) of villa VTO.
When villa VTO connects to door feedback inside door lock, one end of door feedback
connects to ALM2-end (10-pin port 6) of villa VTO, and the other end of door feedback
connects to GND-end (10-pin port 4) )of villa VTO.
4.1.2 Fix VTO onto embedded box.
Figure 4- 8
1. Remove screw a under VTO, and remove decoration cover ①;
2. Use screw b to fix VTO onto 86 box ③inside wall ④;
3. Use screw c to fix VTO onto wall if needed;
4. Install decoration cover ①onto VTO ②, and use screw a to fix.

See Figure 4- 8.Error! Reference source not found..
Figure 4- 9
1. Use screw b to fix bracket onto 86 box embedded/120 box embedded inside ③.
2. Use screw c to fix bracket on ③.
3. Install VTO ①on VTH bracket ②, and fix with screw a.
See Figure 4- 9.Error! Reference source not found.
4.2 Install VTH

4.2.1 Connect wire in VTH embedded box to VTH port. Connect network port to
cable which connects to the switch.
Note: If the switch supplies power to VTH, then do not supply DC 12V power to the
VTH.
Definition of VTH:.
01. Alarm port: 8-ch alarms.
02. Test port: to testing device port.
03. Network port: to VTH.
04. Power: to external DC 12V.
05. Handset port: external handset
See
Figure 4- 10.
Figure 4- 10
01. Alarm port:
1-ALM1: alarm input port 1
2-ALM2: alarm input port 2
3-ALM3: alarm input port 3
4-ALM4: alarm input port 4
5-GND1: public GND 1
6-ALM5: alarm input port 5
7-ALM6: alarm input port 6
8-ALM7: alarm input port 7
9-ALM8: alarm input port 8
10- GND2: public GND 2
See Figure 4- 11.
Figure 4- 11
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali ICRealtime Sistema di interfono