8.0 Certifications
8.1 FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate
the equipment.
8.2 IC
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
8.3 UL 294 and UL 1076
•Communication via Wiegand and RS485 was evaluated by UL and serves as the
interfaces between the reader and panel.
•Communication via Ethernet was not evaluated by UL
•The maximum length of the Ethernet cable when using POE as the power source in
UL installations is limited to 30 meters (98.5 feet).
•When the reader is powered by a supply other than Identiv Mx series controller, the
power supply should be a UL 294 and 1076 listed , class 2 supply.
•For UL 1076, the reader was assessed for the acknowledgement signal annunciation
while interfacing to the Listed Identiv Mx series control unit via RS-485 and Wiegand.
8.3.1 Access control performance levels
Destructive attack : IV
Line Security : I
Endurance : I
Standby Power : I