IDS IDS806 Manuale utente

IDS806
Owner’s Manual
South Africa’s leading manufacturer and distributor of electronic security
products

Owner’s Manual
700-624-01C
2
For Service
Central Station Information:
Account #:
Telephone
Installer Information
Account #:
Telephone
This alarm is to be installed and maintained by an IDS trained installer.

Owner’s Manual
700-624-01C
3
Contents
For Service............................................................................................................................2
Contents...............................................................................................................................3
Glossary................................................................................................................................5
Introduction to the IDS806 ..................................................................................................6
System Information .............................................................................................................9
Arming the System.............................................................................................................10
Disarming the System ........................................................................................................14
Emergency Situations.........................................................................................................15
System Memory.................................................................................................................16
System Configuration.........................................................................................................17
Remote Transmitter...........................................................................................................21
Date and Time....................................................................................................................23
Troubleshooting.................................................................................................................24
Problems when Arming the System...................................................................................25
Problems when Disarming the System ..............................................................................25
Quick Reference User Guide ..............................................................................................26
Index ..................................................................................................................................27

Owner’s Manual
700-624-01C
4
Figure 1: IDS806 Keypad
Power Icon will be on
when there is AC on and
24V DC is present
Zone numbers indicate
the status of each zone
Away Arm icon will be
on when armed in away
mode
Armed icon will be on
when the system is
armed in stay or away
mode
Ready Icon will be on
when the system is in an
arm able state
Star Key is used to
bypass zones and enter
the master user menu
Fire Key is used to
activate the Fire Alarm
Medical Key is used to
activate the Medical
Alarm
Hash Key is used to
cancel any unintended
keypresses
Panic Key is used to
activate the Panic Alarm

Owner’s Manual
700-624-01C
5
Glossary
Alarm Memory
This is the history of the most recent violations that occurred the last time the system was
armed. (See pg. 16)
Arm
To set the system into the ARMED mode. In this mode, violating a zone will activate an
alarm condition. If the system is programmed accordingly, it will cause a reporting code
to be sent to the monitoring company. (See pg. 10)
Bypass
To deactivate a zone. When the panel is ARMED, violation of a bypassed zone will be
ignored. (See pg. 14)
Disarm
To deactivate the system. Fire, medical and panic functions remain active while the
system is disarmed. (See pg. 14)
Entry/Exit Zone
A zone with a programmable time delay, which allows the user to exit the premises after
arming the system and time to get to the keypad after entering the armed premises. This
zone is generally the last exit point of the building and the first entry point i.e. the front
door of a home.
Follower Zone
A zone that may be temporarily violated during the exit delay period or after violation of
an Entry/Exit zone. This allows the user access to disarm the system. A Follower zone will
behave as per an Instant zone if violated prior to the violation of an Entry/Exit zone.
Instant Zone
When the system is armed, violation of an Instant zone will immediately cause an alarm
condition to be registered.
Stay Arm
Arming that allows for certain preprogramed, STAY zones to be violated while the system
is armed. (See pg. 11)
Stay Arm and Go
Arming that allows the user to STAY ARM and leave the premises. (See pg. 12)
Stay Zone
Zones which are bypassed automatically when the system is STAY ARMED. (See pg. 11)
Zone
A specific area of your premises guarded by sensors which detect violations of that area.

Owner’s Manual
700-624-01C
6
Introduction to the IDS806
The IDS806 Control Panel is manufactured to the highest specification and will provide
many years of service if correctly installed and maintained. The unit is designed for
simple operation yet provides the maximum protection for you, your family, or business.
For trouble free operation, please follow the instructions contained in this User Manual.
Your security system consists of a control panel, one or more keypads and various
sensors and detectors. An enclosure will contain the control panel which includes the
system electronics and standby battery. There is normally no reason for anyone other
than the installer or service professional to have access to the control panel.
Notes
1. This alarm is to be installed and maintained by an IDS trained installer.
2. Read the entire manual carefully and keep it in an accessible place.
3. Your security system should be installed and serviced by a qualified security
professional who should instruct you regarding the level of protection provided
and the operation of the system.
4. Should you have any questions regarding the operation of the system, contact
your security company representative.
5. Your system should be tested on a regular basis. Before testing the system, please
notify your security company of your intention to do so.
6. NEVER disconnect the mains power, as the back-up battery will eventually
discharge thereby causing the control panel to shutdown.
7. A security system cannot prevent emergencies. It is only intended to alert you and
- if included - your security company of an emergency situation.
8. Smoke and heat detectors may not detect all fire situations.

Owner’s Manual
700-624-01C
7
Understanding the Keypad Indicators
Refer to the labelled pictures of the keypads.
Table 1: Icon Display Information
Icons
Description
System Disarmed
System Away Armed
Alarm Condition
(Check Alarm Memory zone details BEFORE re-arming)
System Stay Armed
Stay Alarm Condition
Mains Power is Present
Trouble Condition
System Ready to be armed
Zone Bypassed
Zone Clear
Zone Violated or Tampered
Icon representation explanation
= On
= Off
= Flashing

Owner’s Manual
700-624-01C
8
Operation of the Keypad
To ensure correct operation of your security system it is essential to familiarize yourself
with the use of the keypad.
The keypad has a buzzer, command entry keys, zone and system status LED's.
The keypad is used to send commands to the system and to display the current
system status.
The keypad(s) should be mounted in a convenient location within the protected
premises generally close to the Entry/Exit zones.
After a preprogramed period of inactivity, the keypad will automatically enter into
a power-save mode by turning off all the indicators. The keypad "wakes up" or
comes on when any key is pressed or any zones are violated. The power save
feature is programmable and may be disabled.
A sensor which has registered an alarm condition will be indicated on the keypad
by the corresponding zone light flashing.
The keypad buzzer will sound under the following conditions.
oWhen any key is pressed during the entry of codes.
oThree times if one or more of the zones are violated when attempting
to arm the system.
oTo indicate a trouble condition if enabled in programming.
oDuring the entry/exit delay.
oWill sound 5 times when a chime zone is violated.

Owner’s Manual
700-624-01C
9
System Information
Programmed Functions
Check with your installer which of the following functions have been enabled.
Quick Away Arm
Quick Stay Arm
Arm with Entry/Exit or Follower Zones Violated
Stay Arm
Stay Arm and Go
Forced Arming
Siren Sound on Arm/Disarm (single toot - arm/ double2 toot - disarm)
Panic Alarm
Fire Alarm
Chime Zones
Buzz Zones
Zone Tamper Monitoring
Arm with Key-switch or Remote Control
Exit Delay with Key-switch or Remote Control
User Codes
User No.
User Name
Remote Serial Number
01 (Master)
02
03
04
05
06
07
08
09
10
11
12
13
14 (Maid’s)
15 (Duress)

Owner’s Manual
700-624-01C
10
Zone Information
Zone
Zone Type e.g. Entry/Exit
Zone Name e.g. Kitchen Door
1
2
3
4
5
6
7
8
The Primary Entry Delay is
Seconds
The Secondary Entry Delay is
Seconds
The Exit Delay Is
Seconds
Arming the System
There are various options for arming the system
Away Arming
[#]+ [USER CODE]
(Leave via Entry/Exit Zone)
1. Ensure that the Ready icon is on; if not, check that all protected doors and
windows are closed and that motion has ceased in areas with motion detectors.
2. If necessary, close the front door.
3. Press the key to cancel any unintended key entries.
4. Enter a valid 4 digit [USER CODE] . If you make a mistake,
press the key and re-enter the code.
5. The ARMED icon will come on and the keypad will beep for the duration of the
exit delay. A steadily lit zone indicator will show any bypassed zones.
6. The arming process has begun. Leave only via the Follower and Entry/Exit zones.
7. The panel will arm at the end of the exit delay.
Quick Away Arming
Hold down the key until the beep
If this function is enabled, it is possible to AWAY arm by simply holding down the
key until the keypad buzzer sounds and the arming process begins.