IEI Technology 212eM Istruzioni per il montaggio

212eM/242eM
Standalone Keypad
Installation/
Programming Manual
This equipment is designed to be installed and serviced by security
and lock industry professionals.
Contents
Section 1: Features and Product Description
Section 2: Specifications
Section 3: Keypad Tampering
Section 4: Mounting
Section 5: Wiring
Section 6: Testing the Keypad
Section 7: Programming
Section 8: Troubleshooting
Section 9: Programming Mode Loopback
Section 10: Warranty
Manual Revision Date: 02/10/04 Firmware Version: 1.0b
Service Company. Put Contact Information Here:
Company Name:
Service Number:
Document # 6174000, Rev. 1.1 1

1. Features and Product
Description
1.1 Features
•Flush Mount, Single Gang
•Rugged Metal Construction for Indoor and Outdoor Use
•Durable Metal Braille Keys
•Keypad Programmable
•Access Control Functionality*
•Individually Control up to 4 Devices*
•Keypress Feedback via Built-In Sounder
•Bi-Color Red/Green LED Indicates Relay Status
•Yellow LED Indicates Program Mode
•120 Users
•Panic and Duress Options
•Single Use Codes
•Lockout Users
•Passage/Toggle Codes
•10 to 30 Volt DC Operation
•12 to 24 Volt AC Operation
•2AmpMainRelay
•Remote Trigger Input (REX)
•Door Monitor Input
•5-Year Warranty
* 242eM only
1.1.1 Output Functionality Options (242eM only)
•Four Independent Relay Outputs
•Four Independent Relay Timers
•All Relay Outputs Assignable By Code
1.1.2 Access Control Features (242eM only)
•Lock Release Output With Timer
•Alarm Zone Shunt Relay
•Propped Door Alarm Relay
•Forced Door Alarm Relay
IEI 212eM/242eM Standalone Installation/Programming Manual
2 Document # 6174000, Rev. 1.1

1.2 Product Description
The 242eM keypad features the most flexibility and options avail-
able in a self-contained unit. It has an accessory relay board that
provides an additional three relays. It can perform access control
functions and also its four relay outputs can be assigned inde-
pendently for timed operation or to latch. The 242eM keypad can
control up to four devices, and is perfect for controlling electronic
locking devices, security systems, CCTV systems, automatic opera-
tors, or machinery.
The 212eM keypad features a single-relay output to control any de-
vice requiring an on/off switch. The output is timed or latched
and operated by a user’s PIN code. Additionally, the 212eM key-
pad provides basic keyless entry by controlling a door locking de-
vicewheresecurityisnotanissue.
All eM style keypads are designed for both indoor and outdoor
flush mount applications. The electronics for each keypad are con-
formal coated in the manufacturing process in order to provide
this level of application flexibility. In addition, each keypad uses
metal keys to assure long-term, high-quality performance. All eM
style keypads mount to any standard single-gang electrical box or
directly to any wall.
NOTE: This manual covers both 212eM and 242eM. All features
referring to the additional relays and outputs are available only
on the 242eM model.
IEI 212eM/242eM Standalone Installation/Programming Manual
Document # 6174000, Rev. 1.1 3

2. Specifications
Parameter Range/Description
Voltage 10-30 VDC,
12-24 VAC
Current
46mA@10VDC,
68mA@30VDC,
49mA@12VAC, and 60mA@24VAC
Add 20 mA for each auxillary relay
Environment Indoor and Outdoor
Temperature Tolerance -20°F to 130°F (-28°C to 54°C)
Dimensions 4.5" H x 2.75" W x 0.60" D
Main Relay (Form C) Contact Rating: 2A @
30VAC/DC
Auxillary Relay (Form C) Contact Rating: 1A @
24V AC/DC
REX Input Normally Open Dry Contact
Door Position Input Normally Closed Dry Contact
LEDs Bi-Color Red/Green
Yellow
212eM/242eM Default Settings
Parameter Default Setting
Master Code 1234
Lock Output Relay 1 (Main Relay)
Alarm Shunt Relay 2
Propped Door Relay 3
Forced Door Relay 4
Audio Alerts Not Assigned
REX Triggers Lock Output
REX Operation Always Triggers (regardless of
Door Loop)
Error Lockout Enabled
Error Lockout Threshold 3 Attempts
Error Lockout Duration 10 Seconds
Lock Output Time 5 Seconds
Propped Door Time 30 Seconds
Forced Door Time 10 Seconds
Visual Keypress Feedback Enabled
Audio Keypress Feedback Enabled
Auto-Entry Enabled
User Lockout Enabled
IEI 212eM/242eM Standalone Installation/Programming Manual
4 Document # 6174000, Rev. 1.1

3. Keypad Tampering
To prevent tampering, a tamper switch can be installed in the sin-
gle gang box used for mounting the keypad. The tamper switch
must activate if the keypad is removed from the box and must dis-
connect power from the lock. The lock must be a fail-secure de-
vice, meaning the lock remains locked when power is removed. In
addition, once the tamper device is activated, it must be configured
so that it can only be reset from within the protected area. Only a
Sentrol 3012 or Sentrol 3025T tamper switch can be used. The dia-
grams on the next page show the suggested mounting location for
each device.
3.1 IEI Tamper Power Supplies
IEI access system power supplies are designed specifically for ac-
cess control applications. Two models are available: board level
and in a cabinet. Both feature a tamper circuit with a reset button
mounted on the circuit board. Using the tamper switch as detailed
and connected to the power supply tamper circuit, unauthorized
opening of the case or prying the unit off the wall triggers this tam-
per loop, thus preventing the lock from being released until the re-
set button is pressed.
How to Order
•Access power supply with tamper circuit - in cabinet:
0291200
•Access power supply with tamper circuit - board level:
0291100
IEI 212eM/242eM Standalone Installation/Programming Manual
Document # 6174000, Rev. 1.1 5

Figure 1 Mounting a Sentrol 3012 Tamper Switch
Figure 2 Mounting a Sentrol 3025T Tamper Switch
IEI 212eM/242eM Standalone Installation/Programming Manual
6 Document # 6174000, Rev. 1.1

4. Mounting
Thekeypadisdesignedtobeflushmountedusingastandardsingle-
gang electrical box. In addition, itcanbeflushmounteddirectlyto
the wall surface by cutting a hole in the wall. To properly size the
mounting and wire access hole, use the installation template on the
last page in this manual and on the unit’s container.
Mounting height can vary depending on requirements. An appro-
priate range is typically between 48 and 52 inches on center off the
floor.
For outdoor installations, use a weatherproof backbox and seal the
wire entry locations with silicone and provide a drain hole. In addi-
tion, use the anti-oxidant grease pack for the wire harness connec-
tors.
Figure 3 212eM/242eM Mounting Height
IEI 212eM/242eM Standalone Installation/Programming Manual
Document # 6174000, Rev. 1.1 7

5. Wiring
5.1 Wire Harness Configuration
Pin Wire Color Signal Name
1 Red V+ (Keypad Power)
2 Black V- (Keypad Power)
3 White/Black Not Used
4 White/Yellow Not Used
5 Brown Remote Trigger (REX)
6 White/Orange Loop Common
7 White Door Loop Monitor
8 Green Main Relay - Normally
Open
9 Blue Main Relay - Common
10 Gray Main Relay - Normally
Closed
Figure 4 Keypad Connector and Wire Harness
NOTE: For wiring the accessory relay board, see sections 5.6 and
5.7.
IEI 212eM/242eM Standalone Installation/Programming Manual
8 Document # 6174000, Rev. 1.1

5.2 Wiring the Keypad to a Maglock (Fail-Safe)
(Utilizing the same power supply for both the keypad and the lock.)
Use the following steps to connect thekeypadtoaMaglock(Fail-
Safe):
1. Connect the red wire (V+) to the blue wire (common), and
then connect them to the positive on the power supply.
2. Connect the gray wire (normally closed) to the positive on
the maglock.
3. Connect the black wire (V-) to the negative on the Maglock,
and then connect them to the negative on the power supply.
5.3 Wiring the Keypad to an Electric Strike
(Fail-Secure)
(Utilizing the same power supply for both the keypad and the
lock.)
Use the following steps to connect the keypad to an electric strike
(fail-secure) (seeFigure6forreference):
1. Connect the red wire (V+) to the blue wire (common), and
then connect them to the positive on the power supply.
2. Connect the green wire (normally open) to the positive on
the strike.
3. Connect the black wire (V-) to the negative on the strike, and
then connect them to the negative on the power supply.
Figure 5 Wiring the Keypad to a Maglock (Fail-Safe)
IEI 212eM/242eM Standalone Installation/Programming Manual
Document # 6174000, Rev. 1.1 9

5.4 Shunting a Normally Closed Zone
Use the following steps to employ the keypad to shunt a normally
closed zone:
1. Connect the blue wire (common) to the common connection
on the door position switch.
2. Connect the green wire (normally open) to the normally
closed connection on the door position switch.
Figure 6 Wiring the Keypad to Electric Strike
Figure 7 Shunting a Normally Closed Zone
IEI 212eM/242eM Standalone Installation/Programming Manual
10 Document # 6174000, Rev. 1.1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali IEI Technology Tastiera