3
Burn prevention:
Use appropriate protective clothing and footwear to protect against burns from arc radiation and spatters,
Avoid staining clothing with grease and oil that can ignite it.
Explosion and fire prevention:
It is forbidden to operate the device and weld in rooms where there is a risk of explosion or fire,
The welding station should be equipped with fire extinguishing equipment,
The welding station should be at a safe distance from flammable materials.
Prevention of negative effects of noise:
Use ear plugs or other noise protection measures,
Warn of the danger of nearby people.
WARNING!
Do not use a power source for thawing frozen pipes.
Before starting the device:
Check the condition of electrical and mechanical connections. Holders and cables with damaged
insulation must not be used. Inadequate insulation of the grips and current leads can cause electric
shock,
Ensure proper working conditions, i.e. ensure proper temperature, humidity and ventilation at the
workplace. Protect against atmospheric precipitation outside enclosed rooms,
Place the charger in a place that allows easy operation. Persons operating the welder should:
have the authorization to electric welding with coated electrodes and the TIG method,
know and comply with the health and safety regulations applicable to welding work,
use proper, specialized protective equipment: gloves, apron, rubber boots, shield or welding
helmet with a properly selected filter,
know the content of these operating instructions and use the welder for its intended purpose. Any repairs
to the device may only be carried out after disconnecting the plug from the power socket.
When the device is connected to the network, no parts forming the welding current circuit may be touched
by bare hands or wet clothing.
It is forbidden to remove the outer covers when the device is connected to the network.
Any modifications of the rectifier on your own are prohibited and may constitute a deterioration of safety
conditions.
All maintenance and repair works may only be carried out by authorized persons, observing the safety
conditions in force for electrical equipment.
It is forbidden to use the welder in rooms at risk of explosion or fire! The welding station should be
equipped with fire extinguishing equipment.
After finishing work, disconnect the power cord from the device.
The threats and general health and safety rules presented above do not cover the welder's safety issues,
as they do not take into account the specificity of the workplace. An important supplement to these is the
workplace
OHS instructions as well as training and instructions given by supervisory staff.
3.GENERAL DESCRIPTION
The machine is used for manual welding of structural steels with coated electrodes (MMA method) and
quality steels, copper and its alloys with a non-fusible electrode in an inert gas shield (TIG method). The
device is intended for workshop and occasional production work. The welder has the possibility of welding
with pulse and regulation, time of current drop and gas outflow. The device works in 2T / 4T mode and has a
display indicating welding parameters. The set includes a TIG welding torch, electrode cable and ground
cable.
The machine is made in IGBT technology that allows a significant reduction in the weight and
dimensions of the welder and an increase in efficiency while reducing energy consumption.
The machine is used in closed or roofed rooms, not exposed to direct weather effects.
4. TECHNICAL SPECIFICATIONS
4.1 MACHINE
MMA: 6.6 KVA, TIG: 4,6 KVA
MMA: 4,6 KVA, TIG: 3.0 KVA
Welding current / work cycle
MMA: 180 A / 60%
TIG: 200 A / 60%
MMA: 130 A / 60%
TIG: 140 A / 60%