iGenix IG9706 Manuale utente

Please read these instructions carefully before use and retain for future reference
Before switching on your appliance,
always check for any damage which may have been caused in transit
IG9706
Batch code:
5 Litre Air Cooler
USER MANUAL

2
CONTENTS
Important Safety Instructions...............................................3-5
Appliance Overview.................................................................. 6
Operating Instructions.........................................................6-10
Cleaning and Maintenance ............................................... 10-11
Trouble Shooting Guide.......................................................... 12
Disposal Information.............................................................. 13
Fuse Replacement.................................................................... 13
Terms and Conditions and Warranty Information...... 14-15

3
SAFETY INSTRUCTIONS
Carefully read the instructions before operating the unit.
Please retain this manual for future reference.
1. If the supply cord is damaged, it must be replaced by the
manufacturer, a service agent or a similarly qualied person to
avoid a hazard.
2. Household and indoor use only.
3. This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
4. Unplug the appliance during lling and cleaning.
5. Prior to cleaning or other maintenance, the appliance must be
disconnected from the supply mains.
6. Correct Disposal of this product
This marking indicates that this product should not be
disposed with other household wastes throughout the
UK/EU.To prevent possible harm to the environment or
human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material
resources.To return your used device, please use the return
and collection systems or contact the retailer where the
product was purchased.They can take this product for
environmental safe recycling.The packaging material is
recyclable. Dispose of the packaging in an environmentally
friendly manner and make it available for the recyclable
material collection-service.
7. Non-specialized personnel or unauthorized repair personnel
shall not repair or modify the machine.
8. Under no circumstances can the appliance be used with wet

4
hands.This is to avoid electric shock.
9. If the unit is not in use for a long time, unplug the power cord.
10. To prevent accidental injury or damage to the unit, please do not
insert any foreign matter into the air inlet and outlet, because the
unit incorporates a high-speed wind rotor.
11. It is prohibited to use this unit in environments with ammable
and explosive gases and direct sunlight for a long period shall be
avoided.
12. Do not place this unit on an incline or uneven ooring. It must be
on level ooring to work properly.
13. This machine has a safety switch. If the honeycomb lter support
has not been installed well, the unit will not work as usual; when
the machine is working, do not remove the honeycomb lter
frame.
14. At any time the water level in the tank shall not exceed “MAX”
(maximum) scale, and during humidication, the total water level
in the tank shall be controlled, and shall not be below “MIN”
(minimum) scale.
15. After the water tank is lled with water, do not tilt or collide
with the unit when placing or moving it.To move the unit body,
please move it slowly from the side to prevent water overow.
16. When in use make sure the unit is stable to prevent it from
falling over. If the unit topples over accidentally, and it contains
water, unplug the power cord immediately and take it to a
qualied service engineer.
17. Do not place items on the unit or cover the unit in any way with
cloth or similar materials.
18. When washing the outer panels of the unit, only use a damp
cloth. Do not use solvents or corrosive cleaning agents.
19. Do not have the air inlet and outlet of the unit close to walls,
curtains and other objects, as they may block the airow and
affect air supply.
20. When in use make sure not to knock or hit the unit as this could
lead to the appliance automatically shutting down. If this happens

5
the unit will need to be manually restarted.
21. Ensure the water is changed regularly, particularly in warmer
temperatures to prevent the water stagnating and creating
odours. If the indoor temperature is below zero, it is best to use
warm water for humidication.
22. Do not place the unit directly below the power outlet.
23. Do not use the unit around the tub, sprinkler or swimming pool.
24. Product repair must be carried out by a qualied service
engineer.
25. To protect against the risk of electrical shock, do not immerse
the unit, cord or plug in water or other liquid.
26. If a damp cloth has been used to wipe the unit, ensure it is dried
again with a dry cloth.
27. Please note that high levels of humidity in a room can lead to
build up of mould. Humidity levels should always be controlled
inside the home wherever possible to prevent this from
happening.
28. Do not permit the area around the humidier to become damp
or wet. If dampness occurs, turn the output of the humidier
down. If the humidier output volume cannot be turned down,
use the humidier intermittently. Do not allow absorbent
materials, such as carpeting, curtains, drapes, or tablecloths, to
become damp.
RULES FOR SAFE OPERATION
1. Never insert ngers, pencils, or any other object through the
grille when air cooler is running.
2. Disconnect air cooler when moving from one location to
another.
3. Be sure air cooler is on a stable surface when operating to avoid
overturning.
4. DO NOT use air cooler by a window, as rain may create
electrical hazard.
5. Household use only.

6
APPLIANCE OVERVIEW
OPERATING INSTRUCTIONS
Guidance on lling with water, disassembling and washing of the water tank
NOTE:
• Ensure that the water tank is regularly emptied and cleaned when the air cooler is left unused for a
prolonged period of time.
• Always remove the power plug when lling with water and cleaning.
• Always make sure that the water pump module is xed securely in place before turning on the air
cooler. If the water pump module is not securely fastened it can affect the performance of the unit
when the Cool Wind function is in use.
• To ll:
Separate water pump module, and fully pull out the water tank, to feed water or clean the water tank.
NOTE: Pictures in the manual are for reference only.
Control panel
Water tank
locking mechanism
Honeycomb lter
Ice box
Water tank

7
Water pump module
Locking mechanism
Filling the water tank
1. Unlock the water tank by rotating
the locking mechanism 90 degrees.
2. Pull out the water tank and ll with water (making
sure not to go over the maximum ll line), then
once lled push the tank back into position and lock
securely.
Removing and cleaning the water tank
1. Rotate the locking mechanism 90 degrees
anticlockwise to release the water pump module
from the water tank (including the water pipe).
2. Once the water pump module has been
detached, carefully remove the water tank from
the unit so that it can be fully emptied of any
stagnant water and cleaned thoroughly.
3. After cleaning the water tank, reinsert the water
pump module back into the water tank. Insert
front hook into the slot of the water tank, and then
rotate locking mechanism clockwise 90°, and close it
as shown below.
4. Push the water tank inside slowly, and
rotate the locking mechanism to secure
back in place

8
Usage of the ice box
NOTE:
1. The ice box can be frozen repeatedly and reused.You can also choose not to use it based on the
temperature.
2. Please keep the ice box closed to prevent damage and liquid leakage.
3. The ice box is made of eco-friendly and toxic-free materials, and can be frozen safely.
4. When using the frozen ice box in the water tank, the temperature at the air outlet will drop after
operating Cool Wind function.
5. Ice blocks can be used to replace the frozen ice box, to create the same cooling effect.
6. Ensure that the water level in the water tank doesn’t exceed the “MAX” (maximum) line on the front
of the water tank, and if the water level is showing as lower than the “MIN” (minimum) please rell
the tank before using the ‘Cool Wind’ function.
1. Pull the water tank out halfway from the air
cooler unit.
2. Take the ice box out of the package and place it
inside a freezer to freeze for more than 3 hours.
Put the frozen ice box in the water tank, and ll
with water, ensuring it stays below the ‘max’ ll line.
Scale of the water tank

9
Control Panel
Active Function Display Function Control Buttons
Buttons Function description
Startup/Standby
Press to turn the product on or off.
Oscillation
Vertical louvres will oscillate if the unit is in operation.
Wind Speed
Choose wind speed from LOW , MEDIUM , and HIGH .
Wind Type
Select from these three types of wind: Normal wind (the wind speed indicator
light is on), sleep wind (sleep wind the indicator light is on), natural wind
(natural wind the indicator light is on).
Delay Timer
Set a delay timer for the air cooler to automatically shut down after a selected
period of time. Press the button repeatedly to cycle through delay shutdown
time options ranging from 1 - 7 hours (the time chosen will be shown by the
sum of the lights that are illuminated on the Active Function Display next to the
Delay Timer button)
Cool Wind
Activating the Cool Wind function will mean the air cooler is adding moisture to
the air from the water drawn out of the tank to help increase the cooling effect
of the unit. If indicator light ashes, rell the water tank before starting this
function.

10
CLEANING & MAINTENANCE
Remote control button description
NOTE:
• The remote control should be normally used within 5 metres of the front of the product and 30
degrees of the deviation angle.
• Battery acid can be harmful, so please always recycle waste batteries safely and separately.
Oscillation
Set Wind Type
Cool Wind
Startup/Standby
“+” increase Wind Speed
“-” decrease Wind Speed
Delay Timer
AAA Battery, 1.5 V
Use manganese or alkaline batteries of type
“AAA”. Do not use rechargeable batteries.
NOTE: On the unit control panel, shows Wind Type selection. On the remote it is shown by
NOTE: On the unit control panel, selects Cool Wind. On the remote, this same function is shown
by .
NOTE:
• Disconnect the power before cleaning the product. Clean after the product is shut down for two
minutes.
• Prevent from using any abrasive tools and solvents that may damage the surface to clean up the
product. Detergent can be used for cleaning, and then wiped clean with a dry cloth afterwards.
Prevent from washing the machine body with water directly, and wash disassemble parts (honeycomb
lter parts) with a soft brush.
• Only replace internal parts once they are fully dry.
• Do not take apart or modify any of the internal pieces. It is recommended that this product should be
checked and cleaned regularly in order to extend its service life.
Indice
Altri manuali iGenix Condizionatore d'aria

iGenix
iGenix IG9909 Manuale utente

iGenix
iGenix IG9911 Manuale utente

iGenix
iGenix IG9901 Manuale utente

iGenix
iGenix IG9919 Manuale utente

iGenix
iGenix IG9750 Manuale utente

iGenix
iGenix IG9703 Manuale utente

iGenix
iGenix IG9703 Manuale utente

iGenix
iGenix IG9704 Manuale utente

iGenix
iGenix IG9902 Manuale utente

iGenix
iGenix IG9909WIFI Manuale utente