Datasheet & Operating instructions ST-30M-DALI2 Page 5/10
www.illuburg.de
Electrical data
Rated input voltage 220...240 Vac
Range of input voltage 198...264 Vac
Range of input voltage (DC) 200...240 Vdc
Frequency 50/60 Hz
Power factor (λ) 0.95 Full Load, 230 Vac
Input current 0.16 A max. Full Load, 230 Vac
Inrush current 8 A max. 50
s, 230 Vac
Output Voltage 9-58 Vdc
Output options
300 mA constant, 9-58 Vdc, 2.7-17 W
350 mA constant, 9-58 Vdc, 3-20 W
400 mA constant, 9-58 Vdc, 3.6-23 W
450 mA constant, 9-58 Vdc, 4-26 W
500 mA constant, 9-58 Vdc, 4.5-29 W
550 mA constant, 9-55 Vdc, 5-30 W
600 mA constant, 9-50 Vdc, 5.4-30 W
650 mA constant, 9-46 Vdc, 5.8-30 W
700 mA constant, 9-42 Vdc, 6.3-30 W
750 mA constant, 9-40 Vdc, 6.7-30 W
800 mA constant, 9-38 Vdc, 7.2-30 W
850 mA constant, 9-35 Vdc, 7.6-30 W
900 mA constant, 9-34 Vdc, 8.1-30 W
Output power (nominal) 30 W max.
Efficiency 85 % max.
Life time 5 Years Full Load, 230 Vac
Dimming DALI-2 (2-100%) (max lead length: 300m)
PUSH (Primary) (2-100%)
1-10V (2-100%)
Operating condition
Operating temperature range (ta) -25...+50 °C
Max. Surface temperature (tc) 85 °C
Permitted rel. humidity 85 %
Protection class II
Type of protection IP20