Iluminar iLW 40W Manuale utente

USER
MANUAL
1-877-540-5588
iluminarlighting.com
iLW 40W IL-4025FSG-120
iLW 60W IL-6025FSG-120
iLW 80W IL-8025FSG-120

2© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.
2
CONTENTS
• Observe all safety precautions (see page 8). Seek the services of a qualified/certified/
licensed/insured electrician, or call ILUMINAR Lighting technicians for assistance.
• DO NOT handle or touch the fixture while in use.
• Connect the fixture only to the power sources of the appropriate voltage using
the correct AC plug type. Protect power cables from being pinched, walked on, or
otherwise damaged. Be especially careful where the power cable enters the power
outlet to the unit. Only connect the fixture to an electrical outlet or extension cord of
comparable standard and level rating.
• The fixture should only be cleaned as directed. Always seek service for your system by
qualified service personnel if any of the following occur:
1. The fixture shows a noticeable change in performance.
2. The power supply cord or plug is damaged.
3. The fixture has been dropped, or the exterior is damaged.
Please read this manual thoroughly prior to installing or operating.
Pre-Install Information ..........................................................
Technical & Phsyical Specications.........................................
Hardware & Accessories ......................................................
Hanging Instructions ............................................................
Mounting Instructions ...........................................................
Important Cautions & Warranty ...........................................
2
3
4
5
7
8
© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.
40W 60W 80W
VOLTAGE / AMPERAGE DRAW
120V 0.35A 0.51A 0.67A
40.6W 59.7W 79.7W
208V 0.21A 0.33A 0.39A41.2W 60.6W 81.2W
240V 0.18A 0.30A 0.34A41.5W 61.3W 81.5W
277V 0.16A 0.27A 0.30A41.9W 62.0W 82.0W

1-877-540-5588
iluminarlighting.com
sales@iluminarlighting.
3
1-877-540-5588
iluminarlighting.com
TECHNICAL SPECS
High
Efficiency
Energy
Saving
Low
Profile
Multiple Spectrum LED Diodes
Emitter Type
PPF
2.5 µmol/J
Efficacy
Input Power
Input Voltage
Finishing Mounting Height
Emitter Cooling
Waterproof Rating
LED Lifespan (90% of Life)
Power Factor
Smart Sensing™ 100V-277V
>18” to top of Canopy
Passive Thermal Management
IP65 for Damp/Wet Conditions
55,000+ Operational Hours
> 90%
Height
Width
Length
Weight
PHYSICALSPECS
29mm / 1.14”
iLW 40W & 60W 1200mm / 47.2”
130mm / 5”
iLW 80W 1500mm / 59”
100 µmol/s
40W
40W
1200mm / 47.2”
130mm / 5”
2.2lbs/1kg
29mm / 1.14”
150 µmol/s
60W
60W
1200mm / 47.2”
2.2lbs/1kg
29mm / 1.14”
130mm / 5”
200 µmol/s
80W
80W
2.75lbs/1.13kg
1500mm / 59”
29mm / 1.14
130mm / 5”
Spectrum Tuned Full Spectrum Growth / Customized Spectrum

© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.
4
HARDWARE AND ACCESSORIES
The iLW LED xture can be hung
from steel cables or can be
mounted to a rack.
Before you begin installation,
check that you have all the
necessary parts to begin.
2 Metal Clips for Hanging Cables
1 iLW Fixture
1 Power Cable
2 Screws for Clips & Hanging Cables
2 Steel Hanging Cables with Cylindrical Lock
IN THE BOX
4 Screws & 4 Anchors
© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.

5
1-877-540-5588
iluminarlighting.com
1Loop the steel cables over the beam, feeding the wire
through its loop and letting the cylindrical lock hang.
Snap the clips onto the light bar’s heat sink.
3
2Using the provided screw, attach the clip to the steel cable’s
cylindrical lock.
HANGING INSTALLATION
(see next page...)

© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.
6
Pull the steel cable down through the cylindrical lock to
adjust the xture height.
A
5
To shorten cable: Press the cable down through the cylindrical lock. (Figure A)
To extend cable: Press metal top down and pull up on cable. (Figure B)
If you use more than one iLW in your grow
room or clone rack, save space by adding in
the iLW Power Hub. e hub comes as a dual-,
tri- or quad-connector that will send power to
each of your iLW xtures without the need of
additional outlets.
ADDITIONAL ACCESSORIES
Adjust the spacing of the clips as needed.
4
B
© Copyright 2020, ILUMINAR Lighting
Subject to change without notice.

7
1-877-540-5588
iluminarlighting.com
S re
Clip
Hole
An hor
Drill 4 holes into an overhead structure or rack. Insert the
provided mounting anchors into the holes and screw the
metal clips directly into the anchors.
1
Snap the bar into the clips.
2
MOUNTING INSTRUCTIONS

1-877-540-5588
iluminarlighting.com
8
PRECAUTIONS
1. Leave at least one inch of space between the xture and the
mounting area for maximum performance and lifespan.
2. ALWAYS wear protective eyewear when looking directly at
the diodes to prevent eye damage.
3. Only handle, clean or move xture when it’s unplugged and
completely cool.
4. Keep the xture free of dust, debris, and deposits to ensure
the maximum potential of the xture.
5. NEVER use a cloth to clean the diodes. This can scratch the
diodes and could potentially break or dislodge them.
6. DO NOT use chemicals to clean the xture. Use ONLY low
pressure air or low pressure water to remove dust and debris.
Please read the following list carefully prior to beginning installation.
At ILUMINAR, we stand behind our products and our
technology as well as our customers. All ILUMINAR LED
xtures are backed by our 5-Year Guarantee. Please visit our
website iluminarlighting.com/warranty for more information.
GUARANTEE
Questo manuale è adatto per i seguenti modelli
5
Indice